High-frequency ultrasound in the measurement of pediatric craniofacial integrity

被引:8
|
作者
Knott, PD
Hazony, D
Karafa, M
Koltai, PJ
机构
[1] Cleveland Clin Fdn, Head & Neck Inst, Sect Pediat Otolaryngol A71, Cleveland, OH 44195 USA
[2] Case Western Reserve Univ, Dept Biomech Engn, Cleveland, OH 44106 USA
[3] Cleveland Clin Fdn, Dept Biostat & Epidemiol, Cleveland, OH 44195 USA
关键词
D O I
10.1016/j.otohns.2004.08.010
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
OBJECTIVE., This study evaluates the use of high-frequency ultrasound in the measurement of the material nature of the pediatric craniofacial skeleton. STUDY DESIGN AND SETTING: Three desiccated human skulls, aged 1 year, 5 years, and adult, underwent ultrasonic evaluation at 6 sites on each hemicranium. RESULTS: The overall mean signal reflection coefficients for the infant, child, and adult skulls are 98.8 mV (13.75 mV SD)), 172mV (24.5 mV SD)), and 230 mV (23.5 mV SD)), respectively. The mean signal reflection coefficient is positively correlated with increasing chronological age. Comparison of intrasubject signal patterns suggests bone density fields, which vary as a function of growth. CONCLUSION: High-frequency ultrasound provides accurate measurements of the osseous impedance of the craniofacial skeleton. Pattern analysis suggests increases in skull density with greater growth and age. SIGNIFICANCE. Although further testing must be performed in vivo, high-frequency ultrasound may accurately measure the osseous impedance of the pediatric craniofacial skeleton.
引用
收藏
页码:851 / 855
页数:5
相关论文
共 50 条
  • [41] Pulse-echo field distribution measurement technique for high-frequency ultrasound sources
    Raum, K
    OBrien, WD
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1997, 44 (04) : 810 - 815
  • [42] Pulse-echo field distribution measurement technique for high-frequency ultrasound sources
    Raum, K
    O'Brien, WD
    1997 IEEE ULTRASONICS SYMPOSIUM PROCEEDINGS, VOLS 1 & 2, 1997, : 1747 - 1750
  • [43] High-frequency ultrasound findings in epididymal malformations
    Xue, Ensheng
    Chen, Shun
    Liang, Rongxi
    Lin, Xiaodong
    Guo, Jingjing
    Huang, Mei
    JOURNAL OF MEDICAL ULTRASONICS, 2014, 41 (01) : 57 - 62
  • [44] Improvements in optical generation of high-frequency ultrasound
    Hou, Yang
    Ashkenazi, Shai
    Huang, Sheng-Wen
    O'Donnell, Matthew
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2007, 54 (03) : 682 - 686
  • [45] Effect of High-Frequency Ultrasound on Targeted Liposomes
    AlSawaftah, Nour M.
    Paul, Vinod
    Awad, Nahid S.
    Husseini, Ghaleb A.
    JOURNAL OF BIOMEDICAL NANOTECHNOLOGY, 2022, 18 (07) : 1793 - 1804
  • [46] High-frequency ultrasound confirmation of positional plagiocephaly
    Regelsberger, Jan
    Delling, Guenter
    Tsokos, Michael
    Helmke, Knuth
    Kammler, Gertrude
    Kraenzlein, Heidi
    Westphal, Manfred
    JOURNAL OF NEUROSURGERY, 2006, 105 (05) : 413 - 417
  • [47] Design of High-frequency Ultrasound Focused Transducer
    Lu Chao
    Jin Cui'e
    Li Ling
    Lu Minghui
    PROCEEDINGS OF THE THIRD INTERNATIONAL SYMPOSIUM ON TEST AUTOMATION & INSTRUMENTATION, VOLS 1 - 4, 2010, : 908 - 913
  • [48] EVALUATION OF ADHERENCE USING HIGH-FREQUENCY ULTRASOUND
    OUAFTOUH, M
    XU, WJ
    OURAK, M
    NONGAILLARD, B
    JOURNAL DE PHYSIQUE IV, 1992, 2 (C1): : 835 - 838
  • [49] High-frequency dynamics of ultrasound contrast agents
    Sun, Y
    Kruse, DE
    Dayton, PA
    Ferrara, KW
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2005, 52 (11) : 1981 - 1991
  • [50] Investigating perfluorohexane particles with high-frequency ultrasound
    Couture, O
    Bevan, PD
    Cherin, E
    Cheung, K
    Burns, PN
    Foster, FS