High-frequency ultrasound in the measurement of pediatric craniofacial integrity

被引:8
|
作者
Knott, PD
Hazony, D
Karafa, M
Koltai, PJ
机构
[1] Cleveland Clin Fdn, Head & Neck Inst, Sect Pediat Otolaryngol A71, Cleveland, OH 44195 USA
[2] Case Western Reserve Univ, Dept Biomech Engn, Cleveland, OH 44106 USA
[3] Cleveland Clin Fdn, Dept Biostat & Epidemiol, Cleveland, OH 44195 USA
关键词
D O I
10.1016/j.otohns.2004.08.010
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
OBJECTIVE., This study evaluates the use of high-frequency ultrasound in the measurement of the material nature of the pediatric craniofacial skeleton. STUDY DESIGN AND SETTING: Three desiccated human skulls, aged 1 year, 5 years, and adult, underwent ultrasonic evaluation at 6 sites on each hemicranium. RESULTS: The overall mean signal reflection coefficients for the infant, child, and adult skulls are 98.8 mV (13.75 mV SD)), 172mV (24.5 mV SD)), and 230 mV (23.5 mV SD)), respectively. The mean signal reflection coefficient is positively correlated with increasing chronological age. Comparison of intrasubject signal patterns suggests bone density fields, which vary as a function of growth. CONCLUSION: High-frequency ultrasound provides accurate measurements of the osseous impedance of the craniofacial skeleton. Pattern analysis suggests increases in skull density with greater growth and age. SIGNIFICANCE. Although further testing must be performed in vivo, high-frequency ultrasound may accurately measure the osseous impedance of the pediatric craniofacial skeleton.
引用
收藏
页码:851 / 855
页数:5
相关论文
共 50 条
  • [21] Dermatological applications of high-frequency ultrasound
    Thiboutot, DM
    MEDICAL IMAGING 1999: ULTRASONIC TRANSDUCER ENGINEERING, 1999, 3664 : 7 - 16
  • [22] High-frequency ultrasound-based thickness measurement of highly attenuating materials
    Wang, Jishuo
    Lai, Quanqing
    Xu, Caibin
    Hu, Ning
    Deng, Mingxi
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2023, 34 (03)
  • [23] Endoscopic high-frequency ultrasound of the larynx
    Arens, C
    Glanz, H
    EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY, 1999, 256 (06) : 316 - 322
  • [24] High-frequency ultrasound of skin tumors
    Freitag, M
    Hermes, N
    Schwarze, HP
    Stucker, M
    Hoffmann, K
    el-Gammal, S
    Altmeyer, P
    SKIN CANCER AND UV RADIATION, 1997, : 1007 - 1022
  • [25] Endoscopic high-frequency ultrasound of the larynx
    C. Arens
    H. Glanz
    European Archives of Oto-Rhino-Laryngology, 1999, 256 : 316 - 322
  • [26] LISTENING TO THE COCHLEA WITH HIGH-FREQUENCY ULTRASOUND
    Torbatian, Zahra
    Garland, Phil
    Adamson, Rob
    Savage, Julian
    Bance, Manohar
    Brown, Jeremy
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2012, 38 (12): : 2208 - 2217
  • [27] High-frequency ultrasound in the diagnosis of pilomatrixoma
    Ulrich, J
    Wesarg, I
    PEDIATRIC DERMATOLOGY, 2001, 18 (02) : 163 - 163
  • [28] High-frequency ultrasound examination of tendons
    Taipei Municipal Chung-Hsing, Hospital, Taiwan
    Ultrasound in Medicine and Biology, 2000, 26 (SUPPL. 2):
  • [29] High-Frequency Ultrasound: A Novel Diagnostic Tool to Measure Pediatric Tonsils in 3 Dimensions
    Kay-Rivest, Emily
    Saint-Martin, Christine
    Daniel, Sam J.
    OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 2019, 161 (05) : 856 - 861
  • [30] MEASUREMENT OF HIGH-FREQUENCY ULTRASOUND IN LIQUIDS USING HIGH-RESOLUTION BRAGG REFLECTION TECHNIQUE
    TAKAGI, K
    NEGISHI, K
    ULTRASONICS, 1978, 16 (06) : 259 - 263