Monitoring of heparin therapy beyond the anti-Xa activity assay: Evaluation of a thrombin generation assay

被引:2
|
作者
Vermeiren, Pauline [1 ]
Vandevelde, Arne [1 ,2 ]
Peperstraete, Harlinde [3 ]
Devreese, Katrien M. J. [1 ,2 ]
机构
[1] Ghent Univ Hosp, Coagulat Lab, Dept Lab Med, Ghent, Belgium
[2] Univ Ghent, Dept Diagnost Sci, Ghent, Belgium
[3] Ghent Univ Hosp, Dept Intens Care Med, Ghent, Belgium
关键词
blood coagulation tests; heparin; reference values; thrombin; MOLECULAR-WEIGHT HEPARIN; UNFRACTIONATED HEPARIN; ANTICOAGULANT-THERAPY; VARIABILITY; PROTEINS; BINDING;
D O I
10.1111/ijlh.13836
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Global coagulation assays may be of added value to the anti-Xa assay for monitoring heparin therapy. Unlike most testing methods, the thrombin generation assay ( TGA) has the ability to assess the overall function of the hemostatic system, which provides information on the anticoagulation status of patients. We compared the TGA, measured with ST Genesia (R) STG-DrugScreen (R) reagent, with the anti-Xa assay for monitoring heparin therapy in inflammatory and non-inflammatory patients. We also determined reference values for STG-DrugScreen (R) thrombin generation (TG) parameters. Methods: Reference values were determined on 120 healthy donors. Furthermore, a spiking experiment with unfractionated heparin (UFH) and low molecular weight heparin (LMWH) was performed, and samples of patients receiving UFH or LMWH were analyzed with ST Genesia (R) and the anti-Xa assay. Results: High discrepancy between TG parameters and anti-Xa activity was observed for low LMWH anti-Xa levels. TG parameters were affected in 36/46 (time to peak) to 42/46 (peak height) patients during UFH therapy with sub-target anti-Xa activity levels. Conclusion: TGA seems insufficiently sensitive for low concentrations of LMWH. There may be an added value of the TGA for monitoring UFH in so-called heparin-resistant patients. Therefore, the TGA has the potential to be introduced as an additional tool for monitoring heparin therapy.
引用
收藏
页码:785 / 795
页数:11
相关论文
共 50 条
  • [21] A MECHANIZED CHROMOGENIC ASSAY FOR THE DETECTION OF ANTI-XA ACTIVITY IN PLASMA
    TENCATE, H
    LAMPING, RJ
    HENNY, CP
    PRINS, A
    TENCATE, JW
    THROMBOSIS AND HAEMOSTASIS, 1983, 50 (01) : 235 - 235
  • [22] The Influence of Free Hemoglobin and Bilirubin on Heparin Monitoring by Activated Partial Thromboplastin Time and Anti-Xa Assay
    Kostousov, Vadim
    Nguyen, Kim
    Hundalani, Shilpa G.
    Teruya, Jun
    ARCHIVES OF PATHOLOGY & LABORATORY MEDICINE, 2014, 138 (11) : 1503 - 1506
  • [23] EVALUATION OF A NEW AMIDOLYTIC ANTI-XA HEPARIN ASSAY, INSENSITIVE TO PLATELET FACTOR-IV - COMPARISON WITH AN AMIDOLYTIC ANTI-IIA HEPARIN ASSAY IN PATIENTS TREATED WITH HEPARIN
    HOORN, RKJ
    NAUTA, THP
    THROMBOSIS AND HAEMOSTASIS, 1991, 65 (06) : 978 - 978
  • [24] Use of heparin calibrated anti-Xa assay for apixaban and rivaroxaban measurement in the context of regional telestroke activity
    Delassasseigne, Celine
    Leroux, Clementine
    Renou, Pauline
    Girard, David
    Lafargue, Anne
    Morel, Stephane
    Belotti, Pierre Thomas
    Weinmann, Laurent
    ANNALES DE BIOLOGIE CLINIQUE, 2023, 81 (03) : 269 - 279
  • [25] Monitoring unfractionated heparin (UFH) therapy: Which anti factor Xa assay is appropriate?
    Ignjatovic, Vera
    Summerhayes, Robyn
    Gan, Andrew
    Than, Jenny
    Chan, Anthony
    Cochrane, Andrew
    Bennett, Martin
    Horton, Stephen
    Shann, Frank
    Lane, Geoff
    Ross-Smith, Maree
    Monagle, Paul
    THROMBOSIS RESEARCH, 2007, 120 (03) : 347 - 351
  • [26] EVALUATION OF A NEW ASSAY FOR THE MEASUREMENT OF ANTI-XA ACTIVITY ON TWO FULLY-AUTOMATED ANALYZERS
    Smahi, Motalib
    Toulon, Pierre
    INTERNATIONAL JOURNAL OF LABORATORY HEMATOLOGY, 2017, 39 : 110 - 110
  • [27] Interference in the anti-Xa heparin activity assay due to hemolysis and icterus during pediatric extracorporeal life support
    Khan, Jenna
    Chandler, Wayne L.
    ARTIFICIAL ORGANS, 2019, 43 (09) : 880 - 887
  • [28] Implementation of edoxaban anti-Xa activity assay in a hospital laboratory and evaluation of its analytical performance
    Lefebvre, Corentin S.
    Luneau, Sophie
    Bentounes, Nun Kalim
    Mauge, Laetitia
    Dumont, Aurelie
    Gaussem, Pascale
    Helley, Dominique
    Smadja, David M.
    Gendron, Nicolas
    ANNALES DE BIOLOGIE CLINIQUE, 2024, 82 (04) : 451 - 460
  • [29] Study of two techniques for heparin therapy monitoring with an amidolytic anti-factor Xa assay
    Rosborough, TK
    Wolfson, PA
    LABORATORY MEDICINE, 2002, 33 (10) : 789 - 790
  • [30] LABORATORY VALIDATION OF A CHROMOGENIC ANTI-XA ASSAY FOR APIXABAN
    Leger, Rachel R.
    Tange, Julie I.
    McBane, Robert D.
    Chen, Dong
    Pruthi, Rajiv K.
    AMERICAN JOURNAL OF HEMATOLOGY, 2018, 93 (09) : E36 - E37