Monitoring of heparin therapy beyond the anti-Xa activity assay: Evaluation of a thrombin generation assay

被引:2
|
作者
Vermeiren, Pauline [1 ]
Vandevelde, Arne [1 ,2 ]
Peperstraete, Harlinde [3 ]
Devreese, Katrien M. J. [1 ,2 ]
机构
[1] Ghent Univ Hosp, Coagulat Lab, Dept Lab Med, Ghent, Belgium
[2] Univ Ghent, Dept Diagnost Sci, Ghent, Belgium
[3] Ghent Univ Hosp, Dept Intens Care Med, Ghent, Belgium
关键词
blood coagulation tests; heparin; reference values; thrombin; MOLECULAR-WEIGHT HEPARIN; UNFRACTIONATED HEPARIN; ANTICOAGULANT-THERAPY; VARIABILITY; PROTEINS; BINDING;
D O I
10.1111/ijlh.13836
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction: Global coagulation assays may be of added value to the anti-Xa assay for monitoring heparin therapy. Unlike most testing methods, the thrombin generation assay ( TGA) has the ability to assess the overall function of the hemostatic system, which provides information on the anticoagulation status of patients. We compared the TGA, measured with ST Genesia (R) STG-DrugScreen (R) reagent, with the anti-Xa assay for monitoring heparin therapy in inflammatory and non-inflammatory patients. We also determined reference values for STG-DrugScreen (R) thrombin generation (TG) parameters. Methods: Reference values were determined on 120 healthy donors. Furthermore, a spiking experiment with unfractionated heparin (UFH) and low molecular weight heparin (LMWH) was performed, and samples of patients receiving UFH or LMWH were analyzed with ST Genesia (R) and the anti-Xa assay. Results: High discrepancy between TG parameters and anti-Xa activity was observed for low LMWH anti-Xa levels. TG parameters were affected in 36/46 (time to peak) to 42/46 (peak height) patients during UFH therapy with sub-target anti-Xa activity levels. Conclusion: TGA seems insufficiently sensitive for low concentrations of LMWH. There may be an added value of the TGA for monitoring UFH in so-called heparin-resistant patients. Therefore, the TGA has the potential to be introduced as an additional tool for monitoring heparin therapy.
引用
收藏
页码:785 / 795
页数:11
相关论文
共 50 条
  • [1] Evaluation of a new anti-Xa heparin assay
    Davidson, S. J.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2009, 7 : 996 - 996
  • [2] Laboratory Monitoring of Heparin Therapy: Partial Thromboplastin Time or Anti-Xa Assay?
    Lehman, Christopher M.
    Frank, Elizabeth L.
    LABMEDICINE, 2009, 40 (01): : 47 - 51
  • [3] A new assay for point of care monitoring of heparin and heparinoid anti-Xa activity
    Hansen, R
    Koster, A
    Mertzlufft, F
    ANESTHESIA AND ANALGESIA, 1999, 88 (04): : U9 - U9
  • [4] Application of anti-Xa assay in monitoring unfractionated heparin therapy in contemporary antithrombotic management
    Safani, Michael
    Appleby, Steve
    Chiu, Ryan
    Favaloro, Emmanuel J.
    Ferro, Emanuel T.
    Johannes, Jimmy
    Sheth, Milan
    EXPERT REVIEW OF HEMATOLOGY, 2023, 16 (01) : 1 - 8
  • [5] AUTOMATED HEPARIN ASSAY BY CHRONOMETRIC EVALUATION OF THE ANTI-XA ACTIVITY OF THE AT-III-HEPARIN COMPLEX
    SAMPOL, J
    ROSSI, JM
    LEJAY, G
    ANNALES DE BIOLOGIE CLINIQUE, 1984, 42 (01) : 21 - 23
  • [6] Evaluation of assay performance monitoring Xa inhibitors with technochrom anti-Xa (AT plus ) and technochrom Anti-Xa
    Wagner, L.
    Geiter, S.
    Stranz, S.
    Kaufmann, V
    Mager, J.
    Graf, M.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 : 123 - 124
  • [7] Reassessment of dextran sulfate in anti-Xa assay for unfractionated heparin laboratory monitoring
    Hardy, Michael
    Cabo, Julien
    Deliege, Antoine
    Douxfils, Jonathan
    Gouin-Thibault, Isabelle
    Lecompte, Thomas
    Mullier, Francois
    RESEARCH AND PRACTICE IN THROMBOSIS AND HAEMOSTASIS, 2023, 7 (08)
  • [8] Liquid anti-Xa assay: rapid monitoring of Xa inhibitors
    Krougliak, V
    Kung, C.
    Triscott, M.
    JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 : 839 - 839
  • [9] Monitoring unfractionated heparin therapy: relationship between eight anti-Xa assays and a protamine titration assay
    Kitchen, S
    Theaker, J
    Preston, FE
    BLOOD COAGULATION & FIBRINOLYSIS, 2000, 11 (02) : 137 - 144
  • [10] Using a single calibration curve with the anti-Xa chromogenic assay for monitoring heparin anticoagulation
    McGlasson, DL
    LABORATORY MEDICINE, 2005, 36 (05) : 297 - 299