Processing-based approach for resolving the sample optic axis in endoscopic polarization-sensitive optical coherence tomography

被引:13
|
作者
Adams, David C. [1 ]
Suter, Melissa J. [1 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Div Pulm & Crit Care Med, Boston, MA 02114 USA
来源
OPTICS EXPRESS | 2018年 / 26卷 / 19期
基金
美国国家卫生研究院;
关键词
TURBID MEDIA; BIREFRINGENCE; ORIENTATION; CONTRAST; OCT;
D O I
10.1364/OE.26.024917
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Fiber-based polarization-sensitive optical coherence tomography (PS-OCT) that utilizes a rotationally-scanning catheter has a variety of potential biomedical applications in luminal organ systems due to its ability to provide intrinsic contrast for birefringent tissue. Incorporating the optic axis (OA) of the tissue greatly enhances this potential by also permitting information about the orientation of the tissue to be extracted; however, measurement distortion that occurs has up to this point made it impossible to obtain accurate sample OA measurements. In this paper we present a straightforward calibration technique that allows the sample OA to be recovered. This technique requires no hardware modifications making it generally applicable, and as a result has tremendous potential in improving the utility of endoscopic PS-OCT image data. (C) 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:24917 / 24927
页数:11
相关论文
共 50 条
  • [1] Optic axis mapping with catheter-based polarization-sensitive optical coherence tomography
    Villiger, Martin
    Braaf, Boy
    Lippok, Norman
    Otsuka, Kenichiro
    Nadkarni, Seemantini K.
    Bouma, Brett E.
    OPTICA, 2018, 5 (10): : 1329 - 1337
  • [2] Endoscopic polarization-sensitive optical coherence tomography
    Pierce, Mark C.
    Shishkov, Milen
    Park, B. Hyle
    Nassif, Nader
    Bouma, Brett E.
    Tearney, Guillermo J.
    de Boer, Johannes F.
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079
  • [3] Optic axis determination accuracy for fiber-based polarization-sensitive optical coherence tomography
    Park, BH
    Pierce, MC
    Cense, B
    de Boer, JF
    OPTICS LETTERS, 2005, 30 (19) : 2587 - 2589
  • [4] Effects of sample arm motion in endoscopic polarization-sensitive optical coherence tomography
    Pierce, MC
    Shishkov, M
    Park, BH
    Nassif, NA
    Bouma, BE
    Tearney, GJ
    de Boer, JF
    OPTICS EXPRESS, 2005, 13 (15): : 5739 - 5749
  • [5] Quantifying three-dimensional optic axis using polarization-sensitive optical coherence tomography
    Liu, Chao J.
    Black, Adam J.
    Wang, Hui
    Akkin, Taner
    JOURNAL OF BIOMEDICAL OPTICS, 2016, 21 (07)
  • [6] Optic axis determination by fibre-based polarization-sensitive swept-source optical coherence tomography
    Lu, Zenghai
    Kasaragod, Deepa K.
    Matcher, Stephen J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (04): : 1105 - 1122
  • [7] Robust reconstruction of local optic axis orientation with fiber-based polarization-sensitive optical coherence tomography
    Li, Qingyun
    Karnowski, Karol
    Noble, Peter B.
    Cairncross, Alvenia
    James, Alan
    Villiger, Martin
    Sampson, David D.
    BIOMEDICAL OPTICS EXPRESS, 2018, 9 (11): : 5437 - 5455
  • [8] Optic axis determination by fiber-based polarization-sensitive swept-source optical coherence tomography
    Lu, Zenghai
    Kasaragod, Deepa K.
    Matcher, Stephen J.
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XV, 2011, 7889
  • [9] Optical polarization tractography based on polarization-sensitive optical coherence tomography
    Yao, Gang
    Wang, Yuanbo
    Ravanfar, Mohammadreza
    Azinfar, Leila
    Yao, Xuan
    Zhang, Keqing
    Duan, Dongsheng
    OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XX, 2016, 9697
  • [10] Correcting Optical-Axis Calculation in Polarization-Sensitive Optical Coherence Tomography
    Fan, Chuanmao
    Yao, Gang
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2010, 57 (10) : 2556 - 2559