Processing-based approach for resolving the sample optic axis in endoscopic polarization-sensitive optical coherence tomography

被引:13
|
作者
Adams, David C. [1 ]
Suter, Melissa J. [1 ]
机构
[1] Harvard Med Sch, Massachusetts Gen Hosp, Div Pulm & Crit Care Med, Boston, MA 02114 USA
来源
OPTICS EXPRESS | 2018年 / 26卷 / 19期
基金
美国国家卫生研究院;
关键词
TURBID MEDIA; BIREFRINGENCE; ORIENTATION; CONTRAST; OCT;
D O I
10.1364/OE.26.024917
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Fiber-based polarization-sensitive optical coherence tomography (PS-OCT) that utilizes a rotationally-scanning catheter has a variety of potential biomedical applications in luminal organ systems due to its ability to provide intrinsic contrast for birefringent tissue. Incorporating the optic axis (OA) of the tissue greatly enhances this potential by also permitting information about the orientation of the tissue to be extracted; however, measurement distortion that occurs has up to this point made it impossible to obtain accurate sample OA measurements. In this paper we present a straightforward calibration technique that allows the sample OA to be recovered. This technique requires no hardware modifications making it generally applicable, and as a result has tremendous potential in improving the utility of endoscopic PS-OCT image data. (C) 2018 Optical Society of America under the terms of the OSA Open Access Publishing Agreement
引用
收藏
页码:24917 / 24927
页数:11
相关论文
共 50 条
  • [21] Intravascular polarization-sensitive optical coherence tomography based on polarization mode delay
    Li, Yan
    Moon, Sucbei
    Jiang, Yuchen
    Qiu, Saijun
    Chen, Zhongping
    SCIENTIFIC REPORTS, 2022, 12 (01)
  • [22] Polarization-sensitive quantum-optical coherence tomography
    Booth, MC
    Di Giuseppe, G
    Saleh, BEA
    Sergienko, AV
    Teich, MC
    PHYSICAL REVIEW A, 2004, 69 (04): : 043815 - 1
  • [23] Noise model for polarization-sensitive optical coherence tomography
    Williams, Paul A.
    Kemp, Nate J.
    Ives, David
    Park, Jesung
    Dwelle, Jordan C.
    Rylander, H. Grady, II
    Milner, Thomas E.
    COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079
  • [24] Polarization-Sensitive Optical Coherence Tomography for Tissue Imaging
    Tang, Shuo
    Zhou, Xin
    2021 PHOTONICS NORTH (PN), 2021,
  • [25] Mapping local optical axis in birefringent samples using polarization-sensitive optical coherence tomography
    Fan, Chuanmao
    Yao, Gang
    JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (11)
  • [26] Detection of drusen by polarization-sensitive optical coherence tomography
    Schlanitz, F. G.
    Ahlers, C.
    Baumann, B.
    Spalek, T.
    Schriefl, S.
    Schuetze, C.
    Pircher, M.
    Goetzinger, E.
    Hitzenberger, C. K.
    Schmidt-Erfurth, U.
    ACTA OPHTHALMOLOGICA, 2010, 88 : 36 - 37
  • [27] Conical scan polarization-sensitive optical coherence tomography
    Lu, Zenghai
    Kasaragod, Deepa
    Matcher, Stephen J.
    BIOMEDICAL OPTICS EXPRESS, 2014, 5 (03): : 752 - 762
  • [28] Polarization-Sensitive Optical Coherence Tomography of Necrotizing Scleritis
    Miura, Masahiro
    Yamanari, Masahiro
    Iwasaki, Takuya
    Itoh, Masahide
    Yatagai, Toyohiko
    Yasuno, Yoshiaki
    OPHTHALMIC SURGERY LASERS & IMAGING, 2009, 40 (06) : 607 - 610
  • [29] Simplified technique for polarization-sensitive optical coherence tomography
    Roth, JE
    Kozak, JA
    Yazdanfar, S
    Rollins, AM
    Izatt, JA
    COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICAL SCIENCE AND CLINICA APPLICATIONS V, 2001, 4251 : 144 - 147
  • [30] Laryngeal Imaging with Polarization-sensitive Optical Coherence Tomography
    Burns, James A.
    Kim, Ki Hean
    Anderson, R. Rox
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS VII, 2011, 7883