Correcting Optical-Axis Calculation in Polarization-Sensitive Optical Coherence Tomography

被引:8
|
作者
Fan, Chuanmao [1 ]
Yao, Gang [1 ]
机构
[1] Univ Missouri, Dept Biol Engn, Columbia, MO 65211 USA
基金
美国国家科学基金会;
关键词
Biomedical optical imaging; image processing; optical imaging; polarization; BIOLOGICAL TISSUE; BIREFRINGENCE; OCT;
D O I
10.1109/TBME.2010.2053927
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Polarization-sensitive optical coherence tomography (PSOCT) has found many applications in imaging birefringence tissue samples. Polarization-sensitive detection is often implemented by utilizing a circularly polarized incident light and detecting the two orthogonal horizontal- and vertical-polarized interference components. However, the obtained optical axes images were inappropriately represented as depth-dependent periodic maps in all reported studies. A detailed analysis confirmed that this misrepresentation was caused by the accumulation of optical retardation with depth. A simple method was proposed to numerically correct this optical-axis calculation. Experimental studies in tendon tissue demonstrated that this method can be applied to map the 2-D optical-axis distributions in enface PSOCT images.
引用
收藏
页码:2556 / 2559
页数:4
相关论文
共 50 条
  • [1] Polarization-sensitive interleaved optical coherence tomography
    Duan, Lian
    Marvdashti, Tahereh
    Ellerbee, Audrey K.
    [J]. OPTICS EXPRESS, 2015, 23 (10): : 13693 - 13703
  • [2] Endoscopic polarization-sensitive optical coherence tomography
    Pierce, Mark C.
    Shishkov, Milen
    Park, B. Hyle
    Nassif, Nader
    Bouma, Brett E.
    Tearney, Guillermo J.
    de Boer, Johannes F.
    [J]. COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079
  • [3] Optical polarization tractography based on polarization-sensitive optical coherence tomography
    Yao, Gang
    Wang, Yuanbo
    Ravanfar, Mohammadreza
    Azinfar, Leila
    Yao, Xuan
    Zhang, Keqing
    Duan, Dongsheng
    [J]. OPTICAL COHERENCE TOMOGRAPHY AND COHERENCE DOMAIN OPTICAL METHODS IN BIOMEDICINE XX, 2016, 9697
  • [4] Mapping local optical axis in birefringent samples using polarization-sensitive optical coherence tomography
    Fan, Chuanmao
    Yao, Gang
    [J]. JOURNAL OF BIOMEDICAL OPTICS, 2012, 17 (11)
  • [5] Polarization-sensitive quantum-optical coherence tomography
    Booth, MC
    Di Giuseppe, G
    Saleh, BEA
    Sergienko, AV
    Teich, MC
    [J]. PHYSICAL REVIEW A, 2004, 69 (04): : 043815 - 1
  • [6] Noise model for polarization-sensitive optical coherence tomography
    Williams, Paul A.
    Kemp, Nate J.
    Ives, David
    Park, Jesung
    Dwelle, Jordan C.
    Rylander, H. Grady, II
    Milner, Thomas E.
    [J]. COHERENCE DOMAIN OPTICAL METHODS AND OPTICAL COHERENCE TOMOGRAPHY IN BIOMEDICINE X, 2006, 6079
  • [7] Polarization-Sensitive Optical Coherence Tomography for Tissue Imaging
    Tang, Shuo
    Zhou, Xin
    [J]. 2021 PHOTONICS NORTH (PN), 2021,
  • [8] Detection of drusen by polarization-sensitive optical coherence tomography
    Schlanitz, F. G.
    Ahlers, C.
    Baumann, B.
    Spalek, T.
    Schriefl, S.
    Schuetze, C.
    Pircher, M.
    Goetzinger, E.
    Hitzenberger, C. K.
    Schmidt-Erfurth, U.
    [J]. ACTA OPHTHALMOLOGICA, 2010, 88 : 36 - 37
  • [9] Polarization-Sensitive Optical Coherence Tomography of Necrotizing Scleritis
    Miura, Masahiro
    Yamanari, Masahiro
    Iwasaki, Takuya
    Itoh, Masahide
    Yatagai, Toyohiko
    Yasuno, Yoshiaki
    [J]. OPHTHALMIC SURGERY LASERS & IMAGING, 2009, 40 (06) : 607 - 610
  • [10] Conical scan polarization-sensitive optical coherence tomography
    Lu, Zenghai
    Kasaragod, Deepa
    Matcher, Stephen J.
    [J]. BIOMEDICAL OPTICS EXPRESS, 2014, 5 (03): : 752 - 762