Development of non-enzymatic and highly selective hydrogen peroxide sensor based on nanoporous gold prepared by a simple unusual electrochemical approach

被引:36
|
作者
Sukeri, Anandhakumar [1 ]
Lima, Alex S. [1 ]
Bertotti, Mauro [1 ]
机构
[1] Univ Sao Paulo, Inst Chem, Ave Prof Lineu Prestes,748, Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Nanoporous gold; Hydrogen peroxide; Low overpotential; Selectivity; Non-enzymatic sensor; HEXACYANOFERRATE MODIFIED ELECTRODE; AMPEROMETRIC DETERMINATION; FILM; ELECTROCATALYSIS; MICROELECTRODES; NANOPARTICLES; REDUCTION; H2O2; BIOSENSORS; EVOLUTION;
D O I
10.1016/j.microc.2017.03.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high surface area nanoporous gold film electrode (NPGF) was prepared by a simple electrochemical route instead of the well-known alloying/dealloying method. Field emission scanning electron microscopy (FE-SEM) and energy dispersive X-ray analysis (EDX) were used to investigate the surface morphology and elemental composition of the as-prepared NPGF electrode. The electrocatalytic activity and sensing behaviour of the developed non-enzymatic NPGF electrode was demonstrated towards hydrogen peroxide (H2O2) reduction employing cyclic voltammetry and amperometry techniques. Cyclic voltammetric measurements confirmed the excellent catalytic activity of the NPGF electrode as a shift in the overpotential (similar to 0.4V) towards less negative direction along with increased current signal compared to the unmodified bare Au electrode were noticed. Additionally, the H2O2 reduction on the NPGF electrode takes place at less negative potential values in comparison with those found for existing NPG electrodes prepared by alloying/dealloying method. The electrochemical sensing of H2O2 at the NPGF electrode was evaluated through amperometric mode by applying a constant potential of -0.2 V in the linear range 10 x 10(-6) mol L-1-1 x 10(-3) mol L-1. The lower detection limit (LOD) was found to be 3.7 x 10(-6) mol L-1 (S/N = 3) and a remarkable selectivity was observed in the presence of major interfering molecules like glucose, ascorbic acid, dopamine and uric acid with high sensitivity (4001 mu A mM(-1) cm(-2)). Other analytical parameters such as reproducibility and stability were well-studied and satisfactory results were obtained. The developed NPGF was used as a sensor probe for H2O2 detection in real samples. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:149 / 154
页数:6
相关论文
共 50 条
  • [21] Non-enzymatic hydrogen peroxide sensor based on a gold electrode modified with granular cuprous oxide nanowires
    Yan, Zhongke
    Zhao, Jianwei
    Qin, Lirong
    Mu, Fan
    Wang, Ping
    Feng, Xining
    MICROCHIMICA ACTA, 2013, 180 (1-2) : 145 - 150
  • [22] Non-enzymatic hydrogen peroxide sensor based on a gold electrode modified with granular cuprous oxide nanowires
    Zhongke Yan
    Jianwei Zhao
    Lirong Qin
    Fan Mu
    Ping Wang
    Xining Feng
    Microchimica Acta, 2013, 180 : 145 - 150
  • [23] Non-enzymatic electrochemical sensor based on Pt/MoSe2 nanomesh for the detection of hydrogen peroxide
    Wu, Qi
    Zhou, Xiaoqing
    Li, Peng
    You, Shengjie
    Ye, Junjie
    Bao, Pengfei
    Chen, Xuedong
    Tong, Hui
    Wang, Shiqiang
    MATERIALS CHEMISTRY AND PHYSICS, 2023, 310
  • [24] Non-enzymatic electrochemical sensing of hydrogen peroxide based on polypyrrole/platinum nanocomposites
    Xing, Liwen
    Rong, Qinfeng
    Ma, Zhanfang
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 221 : 242 - 247
  • [25] Non-enzymatic Glucose Sensor Based on Palladium Coated Nanoporous Gold Film Electrode
    Tavakkoli, Nahid
    Nasrollahi, Shekofe
    AUSTRALIAN JOURNAL OF CHEMISTRY, 2013, 66 (09) : 1097 - 1104
  • [26] A Non-enzymatic Hydrogen Peroxide Sensor with Enhanced Sensitivity Based on Pt Nanoparticles
    Awais, Azka
    Arsalan, Muhammad
    Sheng, Qinglin
    Yue, Tianli
    ANALYTICAL SCIENCES, 2021, 37 (10) : 1419 - 1426
  • [27] A Non-enzymatic Hydrogen Peroxide Sensor with Enhanced Sensitivity Based on Pt Nanoparticles
    Azka Awais
    Muhammad Arsalan
    Qinglin Sheng
    Tianli Yue
    Analytical Sciences, 2021, 37 : 1419 - 1426
  • [28] Simple aminophenol-based electrochemical probes for non-enzymatic, dual amperometric detection of NADH and hydrogen peroxide
    Thiruppathi, Murugan
    Lin, Pei-Ying
    Chou, Yi-Te
    Ho, Hsin-Yu
    Wu, Li-chen
    Ho, Ja-an Annie
    TALANTA, 2019, 200 : 450 - 457
  • [29] Non-enzymatic amperometric hydrogen peroxide sensor for biological applications
    Patel, Jigna
    Knorr, Josh
    Kumar, Amit
    Yestrebsky, Cherie
    Diaz, Diego J.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2013, 245
  • [30] Highly sensitive and selective rGO based Non-Enzymatic electrochemical sensor for propamocarb fungicide pesticide detection
    Tasaltin, Nevin
    Karakus, Selcan
    Tasaltin, Cihat
    Baytemir, Gulsen
    FOOD CHEMISTRY, 2022, 372