Development of non-enzymatic and highly selective hydrogen peroxide sensor based on nanoporous gold prepared by a simple unusual electrochemical approach

被引:35
|
作者
Sukeri, Anandhakumar [1 ]
Lima, Alex S. [1 ]
Bertotti, Mauro [1 ]
机构
[1] Univ Sao Paulo, Inst Chem, Ave Prof Lineu Prestes,748, Sao Paulo, SP, Brazil
基金
巴西圣保罗研究基金会;
关键词
Nanoporous gold; Hydrogen peroxide; Low overpotential; Selectivity; Non-enzymatic sensor; HEXACYANOFERRATE MODIFIED ELECTRODE; AMPEROMETRIC DETERMINATION; FILM; ELECTROCATALYSIS; MICROELECTRODES; NANOPARTICLES; REDUCTION; H2O2; BIOSENSORS; EVOLUTION;
D O I
10.1016/j.microc.2017.03.023
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A high surface area nanoporous gold film electrode (NPGF) was prepared by a simple electrochemical route instead of the well-known alloying/dealloying method. Field emission scanning electron microscopy (FE-SEM) and energy dispersive X-ray analysis (EDX) were used to investigate the surface morphology and elemental composition of the as-prepared NPGF electrode. The electrocatalytic activity and sensing behaviour of the developed non-enzymatic NPGF electrode was demonstrated towards hydrogen peroxide (H2O2) reduction employing cyclic voltammetry and amperometry techniques. Cyclic voltammetric measurements confirmed the excellent catalytic activity of the NPGF electrode as a shift in the overpotential (similar to 0.4V) towards less negative direction along with increased current signal compared to the unmodified bare Au electrode were noticed. Additionally, the H2O2 reduction on the NPGF electrode takes place at less negative potential values in comparison with those found for existing NPG electrodes prepared by alloying/dealloying method. The electrochemical sensing of H2O2 at the NPGF electrode was evaluated through amperometric mode by applying a constant potential of -0.2 V in the linear range 10 x 10(-6) mol L-1-1 x 10(-3) mol L-1. The lower detection limit (LOD) was found to be 3.7 x 10(-6) mol L-1 (S/N = 3) and a remarkable selectivity was observed in the presence of major interfering molecules like glucose, ascorbic acid, dopamine and uric acid with high sensitivity (4001 mu A mM(-1) cm(-2)). Other analytical parameters such as reproducibility and stability were well-studied and satisfactory results were obtained. The developed NPGF was used as a sensor probe for H2O2 detection in real samples. (C) 2017 Elsevier B.V. All rights reserved.
引用
收藏
页码:149 / 154
页数:6
相关论文
共 50 条
  • [1] Nanoporous gold as non-enzymatic sensor for hydrogen peroxide
    Meng, Fanhui
    Yan, Xiuling
    Liu, Jianguo
    Gu, Jun
    Zou, Zhigang
    [J]. ELECTROCHIMICA ACTA, 2011, 56 (12) : 4657 - 4662
  • [2] Non-enzymatic hydrogen peroxide sensor based on a nanoporous gold electrode modified with platinum nanoparticles
    Guang Yin
    Ling Xing
    Xiu-Ju Ma
    Jun Wan
    [J]. Chemical Papers, 2014, 68 : 435 - 441
  • [3] Non-enzymatic hydrogen peroxide sensor based on a nanoporous gold electrode modified with platinum nanoparticles
    Yin, Guang
    Xing, Ling
    Ma, Xiu-Ju
    Wan, Jun
    [J]. CHEMICAL PAPERS, 2014, 68 (04): : 435 - 441
  • [4] A Highly Sensitive Non-Enzymatic Hydrogen Peroxide Sensor based on Palladium-Gold Nanoparticles
    Banerjee, Saikat
    Hossain, Md Faruk
    Slaughter, Gymama
    [J]. 2020 IEEE 15TH INTERNATIONAL CONFERENCE ON NANO/MICRO ENGINEERED AND MOLECULAR SYSTEM (IEEE NEMS 2020), 2020, : 286 - 289
  • [5] Gold nanoparticles for sensitive detection of hydrogen peroxide: a simple non-enzymatic approach
    Sophia, J.
    Muralidharan, G.
    [J]. JOURNAL OF APPLIED ELECTROCHEMISTRY, 2015, 45 (09) : 963 - 971
  • [6] Gold nanoparticles for sensitive detection of hydrogen peroxide: a simple non-enzymatic approach
    J. Sophia
    G. Muralidharan
    [J]. Journal of Applied Electrochemistry, 2015, 45 : 963 - 971
  • [7] A nanocomposite-based electrochemical sensor for non-enzymatic detection of hydrogen peroxide
    Du, Xin
    Chen, Yuan
    Dong, Wenhao
    Han, Bingkai
    Liu, Min
    Chen, Qiang
    Zhou, Jun
    [J]. ONCOTARGET, 2017, 8 (08) : 13039 - 13047
  • [8] A non-enzymatic electrochemical hydrogen peroxide sensor based on copper oxide nanostructures
    Mihailova, Irena
    Gerbreders, Vjaceslavs
    Krasovska, Marina
    Sledevskis, Eriks
    Mizers, Valdis
    Bulanovs, Andrejs
    Ogurcovs, Andrejs
    [J]. BEILSTEIN JOURNAL OF NANOTECHNOLOGY, 2022, 13 : 424 - 436
  • [9] Non-enzymatic electrochemical CuO nanoflowers sensor for hydrogen peroxide detection
    Song, Min-Jung
    Hwang, Sung Woo
    Whang, Dongmok
    [J]. TALANTA, 2010, 80 (05) : 1648 - 1652
  • [10] Non-Enzymatic Electrochemical Hydrogen Peroxide Sensor Based on Copper Oxide Hollow Microspheres
    Shuai, Ying
    Liu, Chuanghua
    Wang, Jia
    Ma, Jun
    Cui, Xiaoyan
    [J]. SENSOR LETTERS, 2013, 11 (10) : 1945 - 1949