Measured and Monte Carlo simulated electron backscatter to the monitor chamber for the Varian TrueBeam Linac

被引:2
|
作者
Lloyd, Samantha A. M. [1 ]
Gagne, Isabelle M. [1 ,2 ]
Bazalova-Carter, Magdalena [1 ]
Zavgorodni, Sergei [1 ,2 ]
机构
[1] Univ Victoria, Dept Phys & Astron, Victoria, BC, Canada
[2] BC Canc Agcy, Vancouver Isl Ctr, Dept Med Phys, Victoria, BC, Canada
来源
PHYSICS IN MEDICINE AND BIOLOGY | 2016年 / 61卷 / 24期
关键词
electron radiation therapy; Monte Carlo; TrueBeam; backscatter; PHOTON BEAMS; MULTILEAF COLLIMATOR; DOSE CALCULATIONS; BREAST-CANCER; THERAPY; ACCELERATORS;
D O I
10.1088/1361-6560/61/24/8779
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
To accurately simulate therapeutic electron beams using Monte Carlo methods, backscatter from jaws into the monitor chamber must be accounted for via the backscatter factor, S-b. Measured and simulated values of Sb for the TrueBeam are investigated. Two approaches for measuring Sb are presented. Both require service mode operation with the dose and pulse forming networking servos turned off in order to assess changes in dose rate with field size. The first approach samples an instantaneous dose rate, while the second approach times the delivery of a fixed number of monitor units to assess dose rate. Dose rates were measured for 6, 12 and 20 MeV electrons for jaw- or MLC-shaped apertures between 1x1 and 40x40 cm(2). The measurement techniques resulted in values of Sb that agreed within 0.21% for square and asymmetric fields collimated by the jaws. Measured values of Sb were used to calculate the forward dose component in a virtual monitor chamber using BEAMnrc. Based on this forward component, simulated values of Sb were calculated and compared to measurement and Varian's VirtuaLinac simulations. BEAMnrc results for jaw- shaped fields agreed with measurements and with VirtuaLinac simulations within 0.2%. For MLC-shaped fields, the respective measurement techniques differed by as much as 0.41% and BEAMnrc results differed with measurement by as much as 0.4%, however, all measured and simulated values agreed within experimental uncertainty. Measurement sensitivity was not sufficient to capture the small backscatter effect due to the MLC, and Monte Carlo predicted backscatter from the MLC to be no more than 0.3%. Backscatter from the jaws changed the electron dose rate by up to 2.6%. This reinforces the importance of including a backscatter factor in simulations of electron fields shaped with secondary collimating jaws, but presents the option of ignoring it when jaws are retracted and collimation is done with the MLC.
引用
收藏
页码:8779 / 8793
页数:15
相关论文
共 50 条
  • [31] Calibrating a virtual linac: Monitor units in Monte Carlo simulations
    Popescu, I
    Shaw, C
    Zavgorodni, S
    Beckham, W
    RADIOTHERAPY AND ONCOLOGY, 2005, 76 : S148 - S149
  • [32] An EGS Monte Carlo model for Varian TrueBEAM treatment units: Commissioning and experimental validation of source parameters
    Lopez-Sanchez, Miguel
    Perez-Fernandez, Maria
    Manuel Fandino, Jose
    Teijeiro, Antonio
    Luna-Vega, Victor
    Gomez-Fernandez, Nicolas
    Gomez, Faustino
    Gonzalez-Castano, Diego M.
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2019, 64 : 81 - 88
  • [33] Monte Carlo simulation of Varian Linac for 6 MV photon beam with BEAMnrc code
    Mohammed, Maged
    El Bardouni, T.
    Chakir, E.
    Boukhal, H.
    Saeed, M.
    Ahmed, Abdul-Aziz
    RADIATION PHYSICS AND CHEMISTRY, 2018, 144 : 69 - 75
  • [34] Validation of Monte Carlo Geant4 code for a 6 MV Varian linac
    EL Bakkali, Jaafar
    EL Bardouni, Tarek
    JOURNAL OF KING SAUD UNIVERSITY SCIENCE, 2017, 29 (01) : 106 - 113
  • [35] Monte Carlo study of photoneutron production in the Varian Clinac 2100C linac
    A. Ma
    J. Awotwi-Pratt
    A. Alghamdi
    A. Alfuraih
    N. M. Spyrou
    Journal of Radioanalytical and Nuclear Chemistry, 2008, 276 : 119 - 123
  • [36] Monte Carlo simulation of the Varian TrueBeam flattened-filtered beams using a surrogate geometry in PRIMO
    Miguel Rodriguez
    Josep Sempau
    Lorenzo Brualla
    Radiation Oncology, 19
  • [37] Monte Carlo study of photoneutron production in the Varian Clinac 2100C linac
    Ma, A.
    Awotwi-Pratt, J.
    Alghamdi, A.
    Alfuraih, A.
    Spyrou, N. M.
    JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2008, 276 (01) : 119 - 123
  • [38] A Monte Carlo Investigation of Low-Z Targets in a TrueBeam Linear Accelerator Using Varian Virtualinac
    Parsons, D.
    Robar, J.
    Sawkey, D.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [39] Monte Carlo simulation of the Varian TrueBeam flattened-filtered beams using a surrogate geometry in PRIMO
    Rodriguez, Miguel
    Sempau, Josep
    Brualla, Lorenzo
    RADIATION ONCOLOGY, 2024, 19 (01)
  • [40] Systematic Monte Carlo dose verification of VMAT treatment plans for TrueBeam linac using PRIMO
    Sottiaux, A.
    Baltieri, V.
    Monseux, A.
    Leclercq, C.
    Vanache, D.
    Tomsej, M.
    RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S932 - S933