Comparison of gamma-ray dosimeters in a field study in the Chernobyl exclusion zone

被引:1
|
作者
Karlik, J. F. [1 ]
Downer, A. J. [2 ]
机构
[1] Univ Calif Cooperat Extens, 1031 S Mt Vernon Ave, Bakersfield, CA 93307 USA
[2] Univ Calif Cooperat Extens, Ventura, CA USA
关键词
RADIATION; FUKUSHIMA; CONSEQUENCES;
D O I
10.1080/10962247.2019.1674752
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Five different models of dosimeters were compared in the Chernobyl Inner Exclusion Zone by measuring gamma radiation in 12 locations. We used an instrument made by Mirion Technologies, Inc., as the reference, since that instrument had an NIST-traceable calibration. Two models of dosimeters gave radiation values similar to the Mirion at all levels of radiation encountered. Two other models gave similar values to the Mirion instrument at low radiation levels but not at higher radiation levels encountered. These results offer a caution regarding the accuracy of inexpensive commercially available radiation instruments. Implications: Comparison of gamma ray dosimeters in the Chernobyl Exclusion Zone showed varying agreement with an NIST-calibrated instrument, as well as varying linearity of response to ambient radiation. These results suggest caution regarding accuracy of inexpensive dosimeters. However, dosimeters used that were manufactured in Ukraine exhibited good agreement with the reference instrument.
引用
收藏
页码:1361 / 1367
页数:7
相关论文
共 50 条
  • [31] EXPERIMENTAL EVALUATION OF GAMMA-RAY RESPONSE CALCULATIONS FOR ENCAPSULATED SOLID-STATE DOSIMETERS
    EMMONS, LL
    SIMONS, GG
    HUNTSMAN, TS
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1976, 24 (NOV19): : 403 - 404
  • [32] A CAPTURE GAMMA-RAY BEAM FOR THE CALIBRATION OF RADIOPROTECTION DOSIMETERS BETWEEN 5 AND 9 MEV
    BERMANN, F
    BORDY, JM
    CHASSENDEBAROZ, P
    DETROUSSEL, P
    DHERMAIN, J
    JAUREGUY, JC
    SOLLIER, T
    RADIATION PROTECTION DOSIMETRY, 1990, 30 (04) : 237 - 243
  • [33] TEMPERATURE AND HUMIDITY EFFECTS ON THE GAMMA-RAY RESPONSE AND STABILITY OF PLASTIC AND DYED PLASTIC DOSIMETERS
    LEVINE, H
    MCLAUGHLIN, WL
    MILLER, A
    RADIATION PHYSICS AND CHEMISTRY, 1979, 14 (3-6): : 551 - 574
  • [34] X-RAY AND GAMMA-RAY SOURCES - COMPARISON OF THEIR CHARACTERISTICS
    FREUND, AK
    NUCLEAR INSTRUMENTS & METHODS, 1979, 166 (01): : 65 - 67
  • [35] GAMMA-RAY DIFFRACTION IN THE STUDY OF SILICON
    KURBAKOV, AI
    SOBOLEV, NA
    MATERIALS SCIENCE AND ENGINEERING B-SOLID STATE MATERIALS FOR ADVANCED TECHNOLOGY, 1994, 22 (2-3): : 149 - 158
  • [36] Theoretical Study of Gamma-ray Pulsars
    Song, Yuzhe
    Cheng, Kwong Sang
    Takata, Jumpei
    JOURNAL OF ASTRONOMY AND SPACE SCIENCE, 2016, 33 (02) : 69 - 73
  • [37] MEASUREMENT OF DEAD ZONE CHARACTERISTICS OF GAS COUNTER WITH GAMMA-RAY
    NOHTOMI, A
    KOORI, N
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1992, 29 (03) : 284 - 287
  • [38] Predicting the radiation exposure of terrestrial wildlife in the Chernobyl exclusion zone: an international comparison of approaches
    Beresford, N. A.
    Barnett, C. L.
    Brown, J. E.
    Cheng, J-J
    Copplestone, D.
    Gaschak, S.
    Hosseini, A.
    Howard, B. J.
    Kamboj, S.
    Nedveckaite, T.
    Olyslaegers, G.
    Smith, J. T.
    Vives i Batlle, J.
    Vives-Lynch, S.
    Yu, C.
    JOURNAL OF RADIOLOGICAL PROTECTION, 2010, 30 (02) : 341 - 373
  • [39] The study for the method of fast and efficient gamma-ray detection for the stereo gamma-ray ddetection system
    Hwang, Young-Gwan
    Lee, Nam-Ho
    Transactions of the Korean Institute of Electrical Engineers, 2014, 63 (09): : 1253 - 1258
  • [40] Probing Gamma-Ray Burst VHE Emission with the Southern Wide-Field-of-View Gamma-Ray Observatory
    La Mura, Giovanni
    Barres de Almeida, Ulisses
    Conceicao, Ruben
    De Angelis, Alessandro
    Longo, Francesco
    Pimenta, Mario
    Tome, Bernardo
    Miceli, Davide
    GALAXIES, 2021, 9 (04):