Comparison of gamma-ray dosimeters in a field study in the Chernobyl exclusion zone

被引:1
|
作者
Karlik, J. F. [1 ]
Downer, A. J. [2 ]
机构
[1] Univ Calif Cooperat Extens, 1031 S Mt Vernon Ave, Bakersfield, CA 93307 USA
[2] Univ Calif Cooperat Extens, Ventura, CA USA
关键词
RADIATION; FUKUSHIMA; CONSEQUENCES;
D O I
10.1080/10962247.2019.1674752
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Five different models of dosimeters were compared in the Chernobyl Inner Exclusion Zone by measuring gamma radiation in 12 locations. We used an instrument made by Mirion Technologies, Inc., as the reference, since that instrument had an NIST-traceable calibration. Two models of dosimeters gave radiation values similar to the Mirion at all levels of radiation encountered. Two other models gave similar values to the Mirion instrument at low radiation levels but not at higher radiation levels encountered. These results offer a caution regarding the accuracy of inexpensive commercially available radiation instruments. Implications: Comparison of gamma ray dosimeters in the Chernobyl Exclusion Zone showed varying agreement with an NIST-calibrated instrument, as well as varying linearity of response to ambient radiation. These results suggest caution regarding accuracy of inexpensive dosimeters. However, dosimeters used that were manufactured in Ukraine exhibited good agreement with the reference instrument.
引用
收藏
页码:1361 / 1367
页数:7
相关论文
共 50 条
  • [21] Gamma-ray spectrometry in the field: Radioactive heat production in the Central Slovakian Volcanic Zone
    Harley, Thomas L.
    Westaway, Rob
    McCay, Alistair T.
    JOURNAL OF VOLCANOLOGY AND GEOTHERMAL RESEARCH, 2017, 338 : 1 - 24
  • [22] AIRBORNE GAMMA SPECTROMETRIC SURVEY IN THE CHERNOBYL EXCLUSION ZONE BASED ON OKTOKOPTER UAV TYPE
    Zabulonov, Yu. L.
    Burtnyak, V. M.
    Zolkin, I. O.
    PROBLEMS OF ATOMIC SCIENCE AND TECHNOLOGY, 2015, (05): : 163 - 167
  • [23] Deconvolving gamma-ray logs by adaptive zone refinement
    Dickson, B. (bruce.dickson@optusnet.com.au), 1600, Society of Exploration Geophysicists (77):
  • [24] APPLICATION OF A FRESNEL ZONE PLATE TO GAMMA-RAY IMAGING
    ROGERS, WL
    BEIERWAL.WH
    JONES, LW
    HAN, KS
    JOURNAL OF NUCLEAR MEDICINE, 1972, 13 (08) : 612 - +
  • [25] Deconvolving gamma-ray logs by adaptive zone refinement
    Dickson, B.
    Craig, M.
    GEOPHYSICS, 2012, 77 (04) : D159 - D169
  • [26] MODIFICATION OF GAMMA-RAY SPECTRUM IN A PHOTON FIELD
    IVANENKO, IP
    SIZOV, VV
    ASTROPHYSICS AND SPACE SCIENCE, 1990, 166 (01) : 17 - 33
  • [27] A Study of Consecutive Terrestrial Gamma-ray Flashes Using the Gamma-ray Burst Monitor
    Stanbro, M.
    Briggs, M. S.
    Roberts, O. J.
    Cramer, E. S.
    Cummer, S. A.
    Grove, J. E.
    JOURNAL OF GEOPHYSICAL RESEARCH-SPACE PHYSICS, 2018, 123 (11) : 9634 - 9651
  • [28] COMPARISON OF NUCLEAR AND GAMMA-RAY ENERGY SCALES
    JONES, KW
    DOUGLAS, RA
    MCELLISTREM, MT
    RICHARDS, HT
    PHYSICAL REVIEW, 1954, 94 (04): : 947 - 952
  • [29] Effect of low irradiation temperature on the gamma-ray response of dyed and undyed PMMA dosimeters
    Biramontri, S
    Haneda, N
    Tachibana, H
    Kojima, T
    RADIATION PHYSICS AND CHEMISTRY, 1996, 48 (01): : 105 - 109
  • [30] SUCCESSIVE GAMMA-RAY IRRADIATION AND CORRESPONDING POST-IRRADIATION ANNEALING OF pMOS DOSIMETERS
    Pejovic, Milic M.
    Pejovic, Momcilo M.
    Jaksic, Aleksandar B.
    Stankovic, Koviljka Dj.
    Markovic, Slavoljub A.
    NUCLEAR TECHNOLOGY & RADIATION PROTECTION, 2012, 27 (04): : 341 - 345