In-Flight Automated External Defibrillator Use and Consultation Patterns

被引:34
|
作者
Brown, Aaron Michael [1 ,2 ]
Rittenberger, Jon C. [2 ]
Ammon, Charles M. [3 ]
Harrington, Scott [2 ]
Guyette, Francis X. [3 ]
机构
[1] Univ Pittsburgh Affiliated Residency Emergency Me, Pittsburgh, PA USA
[2] Univ Pittsburgh, Dept Emergency Med, Pittsburgh, PA 15216 USA
[3] STAT MedEvac, W Mifflin, PA USA
关键词
automated external defibrillator; AED; cardiac arrest; airline; medical consultation; CARDIAC-ARREST;
D O I
10.3109/10903120903572319
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background. Limited information exists about the in-flight use and outcomes associated with automated external defibrillators (AEDs) on commercial airlines. Objective. To describe the characteristics and outcomes of AED use during in-flight emergencies including in-flight cardiac arrest and the associated ground medical consultation patterns. Methods. We collected cases of AED use that were self-reported to an airline consultation service from three U.S. airlines between May 2004 and March 2009. We reviewed all available data files, related consultation forms, and recordings. For each case, demographics, initial rhythm, shock delivery/success, survival to admission, and ground medical consultation use were obtained. Success was defined as the return of a perfusing rhythm. Initial rhythms were classified as sinus, heart block, supraventricular tachycardia (SVT), atrial fibrillation/flutter, asystole, pulseless electrical activity (PEA), and ventricular fibrillation (VF)/ventricular tachycardia (VT). Results. There were a total of 169 AED applications with 40 cardiac arrests. The mean patient ages were 58 years (standard deviation [SD] 15) and 63 years (SD 12), respectively; both populations were 64% male. AEDs were applied for monitoring in 129 (76%) cases with the following initial rhythms: sinus, 114 (88%); atrial fibrillation/flutter, seven (5%); complete heart block, four (3%); and SVT, four (3%). Presenting rhythms among the cardiac arrest population were as follows: asystole, 16 (40%); VF/VT, 10 (25%); and PEA, 14 (35%). Fourteen patients were defibrillated, including nine of the 10 patients with initial VF/VT and five for the presence of VF/VT after resuscitation for initial PEA/asystole. Defibrillation was advised but not performed in the remaining case of initial VF/VT, and no medical consultation was obtained. All five successful defibrillations occurred in patients with initial VF/VT. There were six (15%; 95% confidence interval [CI] 3-27%) survivors, with five survivals occurring after successful defibrillation for initial VF/VT and one with return of a perfusing rhythm after cardiopulmonary resuscitation (CPR) for a junctional rhythm. Survival in those with VF/VT was five of 10 (50%; 95% CI 14-86%). Medications were delivered in two cases. The median time to first shock was 19 seconds (interquartile range [IQR] 12-24 seconds) after AED application. Medical consultation was obtained in 42 (33%) of the 129 AED monitoring cases and 14 (35%) of the 40 cardiac arrest cases. Conclusion. Use of AEDs resulted in 50% survival among those with VF/VT in flight and 15% overall survival for cardiac arrest. Survival is poor among patients presenting with nonshockable rhythms. AEDs are used extensively for in-flight monitoring, with significant rhythms identified. Ground medical consultation is sought in only one-third of AED uses and cardiac arrests.
引用
收藏
页码:235 / 239
页数:5
相关论文
共 50 条
  • [41] TRAINING ST-JOHN-AMBULANCE VOLUNTEERS TO USE AN AUTOMATED EXTERNAL DEFIBRILLATOR
    WALTERS, G
    GLUCKSMAN, E
    EVANS, TR
    RESUSCITATION, 1994, 27 (01) : 39 - 45
  • [42] Architecture Proposal for an Automated Biphasic External Defibrillator
    Portela, A. E.
    Folgueras, J.
    Milanes, A.
    Forneiro, Y.
    WORLD CONGRESS ON MEDICAL PHYSICS AND BIOMEDICAL ENGINEERING, VOL 25, PT 11: BIOMEDICAL ENGINEERING FOR AUDIOLOGY, OPHTHALMOLOGY, EMERGENCY AND DENTAL MEDICINE, 2009, 25 (11): : 13 - +
  • [43] DIAGNOSTIC-ACCURACY OF AN AUTOMATED EXTERNAL DEFIBRILLATOR
    STULTS, KR
    BROWN, DD
    MORRISON, BA
    ARONSON, AA
    KERBER, RE
    CLINICAL RESEARCH, 1984, 32 (04): : A781 - A781
  • [44] Optimizing Defibrillator Deployment with Bus-Mounted Automated External Defibrillator
    Li, Hongmei
    Wu, Ying
    Luo, Taibo
    PREHOSPITAL EMERGENCY CARE, 2024,
  • [45] Public Awareness of Automated External Defibrillator Locations
    Huang, Chien-Tai
    Chen, Chi-Hsin
    Huang, Chun-Hsiang
    Fan, Cheng-Yi
    Chen, Jiun-Wei
    Ma, Matthew Huei-Ming
    Huang, Edward Pei-Chuan
    JAMA NETWORK OPEN, 2024, 7 (10)
  • [46] PERFORMANCE OF AUTOMATED EXTERNAL DEFIBRILLATOR IN HOSPITAL RESUSCITATION
    Garcia Palma, M. J.
    Quirantes Sierra, B.
    de la Chica Ruiz-Ruano, R.
    Comenero Ruiz, M.
    Tuero Leon, G.
    Munoz Marina, V.
    INTENSIVE CARE MEDICINE, 2010, 36 : S417 - S417
  • [47] A comparison of two automated external defibrillator algorithms
    Verbeek, PR
    Turner, D
    Lane, CJ
    Carter, CC
    ACADEMIC EMERGENCY MEDICINE, 1999, 6 (06) : 631 - 636
  • [48] ANALYSIS OF WRECKAGE PATTERNS FROM IN-FLIGHT DISINTEGRATIONS
    MATTESON, FH
    JOURNAL OF SAFETY RESEARCH, 1974, 6 (02) : 60 - 71
  • [49] INAPPROPRIATE ELECTRICAL COUNTERSHOCKS BY AN AUTOMATED EXTERNAL DEFIBRILLATOR
    ORNATO, JP
    SHIPLEY, J
    POWELL, RG
    RACHT, EM
    ANNALS OF EMERGENCY MEDICINE, 1992, 21 (10) : 1278 - 1281
  • [50] DIAGNOSTIC-ACCURACY OF AN AUTOMATED EXTERNAL DEFIBRILLATOR
    STULTS, KR
    BROWN, DD
    MORRISON, BA
    ARONSON, AA
    KERBER, RE
    CIRCULATION, 1984, 70 (04) : 14 - 14