In-Flight Automated External Defibrillator Use and Consultation Patterns

被引:34
|
作者
Brown, Aaron Michael [1 ,2 ]
Rittenberger, Jon C. [2 ]
Ammon, Charles M. [3 ]
Harrington, Scott [2 ]
Guyette, Francis X. [3 ]
机构
[1] Univ Pittsburgh Affiliated Residency Emergency Me, Pittsburgh, PA USA
[2] Univ Pittsburgh, Dept Emergency Med, Pittsburgh, PA 15216 USA
[3] STAT MedEvac, W Mifflin, PA USA
关键词
automated external defibrillator; AED; cardiac arrest; airline; medical consultation; CARDIAC-ARREST;
D O I
10.3109/10903120903572319
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background. Limited information exists about the in-flight use and outcomes associated with automated external defibrillators (AEDs) on commercial airlines. Objective. To describe the characteristics and outcomes of AED use during in-flight emergencies including in-flight cardiac arrest and the associated ground medical consultation patterns. Methods. We collected cases of AED use that were self-reported to an airline consultation service from three U.S. airlines between May 2004 and March 2009. We reviewed all available data files, related consultation forms, and recordings. For each case, demographics, initial rhythm, shock delivery/success, survival to admission, and ground medical consultation use were obtained. Success was defined as the return of a perfusing rhythm. Initial rhythms were classified as sinus, heart block, supraventricular tachycardia (SVT), atrial fibrillation/flutter, asystole, pulseless electrical activity (PEA), and ventricular fibrillation (VF)/ventricular tachycardia (VT). Results. There were a total of 169 AED applications with 40 cardiac arrests. The mean patient ages were 58 years (standard deviation [SD] 15) and 63 years (SD 12), respectively; both populations were 64% male. AEDs were applied for monitoring in 129 (76%) cases with the following initial rhythms: sinus, 114 (88%); atrial fibrillation/flutter, seven (5%); complete heart block, four (3%); and SVT, four (3%). Presenting rhythms among the cardiac arrest population were as follows: asystole, 16 (40%); VF/VT, 10 (25%); and PEA, 14 (35%). Fourteen patients were defibrillated, including nine of the 10 patients with initial VF/VT and five for the presence of VF/VT after resuscitation for initial PEA/asystole. Defibrillation was advised but not performed in the remaining case of initial VF/VT, and no medical consultation was obtained. All five successful defibrillations occurred in patients with initial VF/VT. There were six (15%; 95% confidence interval [CI] 3-27%) survivors, with five survivals occurring after successful defibrillation for initial VF/VT and one with return of a perfusing rhythm after cardiopulmonary resuscitation (CPR) for a junctional rhythm. Survival in those with VF/VT was five of 10 (50%; 95% CI 14-86%). Medications were delivered in two cases. The median time to first shock was 19 seconds (interquartile range [IQR] 12-24 seconds) after AED application. Medical consultation was obtained in 42 (33%) of the 129 AED monitoring cases and 14 (35%) of the 40 cardiac arrest cases. Conclusion. Use of AEDs resulted in 50% survival among those with VF/VT in flight and 15% overall survival for cardiac arrest. Survival is poor among patients presenting with nonshockable rhythms. AEDs are used extensively for in-flight monitoring, with significant rhythms identified. Ground medical consultation is sought in only one-third of AED uses and cardiac arrests.
引用
收藏
页码:235 / 239
页数:5
相关论文
共 50 条
  • [31] Drone Delivery of an Automated External Defibrillator
    Rosamond, Wayne D.
    Johnson, Anna M.
    Zegre-Hemsey, Jessica K.
    NEW ENGLAND JOURNAL OF MEDICINE, 2020, 383 (12): : 1186 - 1188
  • [32] The Development and Application of Automated External Defibrillator
    Huang Yu-rong
    Lv Hua-qiao
    Hou Yuan-yuan
    PROCEEDINGS OF THE 2013 INTERNATIONAL CONFERENCE ON ADVANCED COMPUTER SCIENCE AND ELECTRONICS INFORMATION (ICACSEI 2013), 2013, 41 : 597 - 599
  • [33] NEW USE FOR IN-FLIGHT STETHOSCOPES
    MARKHAM, NI
    LANCET, 1985, 1 (8426): : 468 - 468
  • [34] Discovering frequent patterns for in-flight incidents
    Sene, Alsane
    Kamsu-Foguem, Bernard
    Rumeau, Pierre
    COGNITIVE SYSTEMS RESEARCH, 2018, 49 : 97 - 113
  • [35] Mismatches Between the Number of Installed Automated External Defibrillators and the Annual Rate of Automated External Defibrillator Use Among Places
    Oh, Je Hyeok
    Cho, Gyu Chong
    Ryoo, Seung Mok
    Han, So Hyun
    Woo, Seon Hee
    Jang, Yong Soo
    Cho, Youngsuk
    Sim, Minseob
    Kim, Oh Hyun
    PREHOSPITAL AND DISASTER MEDICINE, 2021, 36 (02) : 183 - 188
  • [36] Automated External Defibrillator (AED) Use Among Paramedics in the Emergency Department - What are the Obstacles in Using the Automated External Defibrillator in the Pre-Hospital Care Settings?
    Khairi, Mohd A. L.
    Azlan, Nik N. M.
    Amri, Faizal H.
    MEDICINE AND HEALTH-KUALA LUMPUR, 2018, 13 (01): : 198 - 207
  • [37] Population density, automated external defibrillator use, and survival in rural cardiac arrest
    Stapczynski, JS
    Svenson, JE
    Stone, K
    ACADEMIC EMERGENCY MEDICINE, 1997, 4 (06) : 552 - 558
  • [38] Post-shock chest compression delays with automated external defibrillator use
    Berg, MD
    Clark, LL
    Valenzuela, TD
    Kern, KB
    Berg, RA
    RESUSCITATION, 2005, 64 (03) : 287 - 291
  • [39] THE USE OF CARDIOPULMONARY RESUSCITATION AND THE AUTOMATED EXTERNAL DEFIBRILLATOR IN THE PRACTICE OF SPORTS PHYSICAL THERAPY
    Smith, Danny
    Hoogenboom, Barb
    INTERNATIONAL JOURNAL OF SPORTS PHYSICAL THERAPY, 2011, 6 (03): : 267 - 270
  • [40] Are There Any Cultural Barriers to Automated External Defibrillator Use in Middle Eastern Countries?
    Merrigan, Orla H.
    CIRCULATION, 2011, 124 (21)