In-Flight Automated External Defibrillator Use and Consultation Patterns

被引:34
|
作者
Brown, Aaron Michael [1 ,2 ]
Rittenberger, Jon C. [2 ]
Ammon, Charles M. [3 ]
Harrington, Scott [2 ]
Guyette, Francis X. [3 ]
机构
[1] Univ Pittsburgh Affiliated Residency Emergency Me, Pittsburgh, PA USA
[2] Univ Pittsburgh, Dept Emergency Med, Pittsburgh, PA 15216 USA
[3] STAT MedEvac, W Mifflin, PA USA
关键词
automated external defibrillator; AED; cardiac arrest; airline; medical consultation; CARDIAC-ARREST;
D O I
10.3109/10903120903572319
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background. Limited information exists about the in-flight use and outcomes associated with automated external defibrillators (AEDs) on commercial airlines. Objective. To describe the characteristics and outcomes of AED use during in-flight emergencies including in-flight cardiac arrest and the associated ground medical consultation patterns. Methods. We collected cases of AED use that were self-reported to an airline consultation service from three U.S. airlines between May 2004 and March 2009. We reviewed all available data files, related consultation forms, and recordings. For each case, demographics, initial rhythm, shock delivery/success, survival to admission, and ground medical consultation use were obtained. Success was defined as the return of a perfusing rhythm. Initial rhythms were classified as sinus, heart block, supraventricular tachycardia (SVT), atrial fibrillation/flutter, asystole, pulseless electrical activity (PEA), and ventricular fibrillation (VF)/ventricular tachycardia (VT). Results. There were a total of 169 AED applications with 40 cardiac arrests. The mean patient ages were 58 years (standard deviation [SD] 15) and 63 years (SD 12), respectively; both populations were 64% male. AEDs were applied for monitoring in 129 (76%) cases with the following initial rhythms: sinus, 114 (88%); atrial fibrillation/flutter, seven (5%); complete heart block, four (3%); and SVT, four (3%). Presenting rhythms among the cardiac arrest population were as follows: asystole, 16 (40%); VF/VT, 10 (25%); and PEA, 14 (35%). Fourteen patients were defibrillated, including nine of the 10 patients with initial VF/VT and five for the presence of VF/VT after resuscitation for initial PEA/asystole. Defibrillation was advised but not performed in the remaining case of initial VF/VT, and no medical consultation was obtained. All five successful defibrillations occurred in patients with initial VF/VT. There were six (15%; 95% confidence interval [CI] 3-27%) survivors, with five survivals occurring after successful defibrillation for initial VF/VT and one with return of a perfusing rhythm after cardiopulmonary resuscitation (CPR) for a junctional rhythm. Survival in those with VF/VT was five of 10 (50%; 95% CI 14-86%). Medications were delivered in two cases. The median time to first shock was 19 seconds (interquartile range [IQR] 12-24 seconds) after AED application. Medical consultation was obtained in 42 (33%) of the 129 AED monitoring cases and 14 (35%) of the 40 cardiac arrest cases. Conclusion. Use of AEDs resulted in 50% survival among those with VF/VT in flight and 15% overall survival for cardiac arrest. Survival is poor among patients presenting with nonshockable rhythms. AEDs are used extensively for in-flight monitoring, with significant rhythms identified. Ground medical consultation is sought in only one-third of AED uses and cardiac arrests.
引用
收藏
页码:235 / 239
页数:5
相关论文
共 50 条
  • [1] In-Flight Sudden Cardiac Arrest and Automated External Defibrillator Use
    Bassi, Mario
    Kuchtaruk, Matthew
    Jiang, Nathan
    Sartor, Cameron
    Baranchuk, Adrian
    CIRCULATION, 2024, 150
  • [2] Automated external defibrillator use during cardiopulmonary resuscitation during flight
    Lapostolle, F
    Mahaut, JM
    Crocheton, N
    Levasseur, J
    Adnet, F
    ANNALES FRANCAISES D ANESTHESIE ET DE REANIMATION, 2003, 22 (03): : 235 - 237
  • [3] Automated external defibrillator use in dentistry
    Haas, Daniel
    JOURNAL OF THE CANADIAN DENTAL ASSOCIATION, 2007, 73 (04): : 289 - 289
  • [4] Intraoperative use of automated external defibrillator
    Jones, FD
    Fahy, BG
    JOURNAL OF CLINICAL ANESTHESIA, 1999, 11 (04) : 336 - 338
  • [5] Performance of automated external defibrillators under conditions of in-flight turbulence
    Hung, Kevin K. C.
    Graham, Colin A.
    Chan, Lok-Kwan
    Poon, Wai K.
    Rainer, Timothy H.
    Cocks, Robert A.
    RESUSCITATION, 2018, 130 : 41 - 43
  • [6] Automated external defibrillator Trends of automated external defibrillator training in Saudi Arabia, and global perspectives on use and deployment
    Berhanu, Alamin
    Al Nasser, Manal
    SAUDI MEDICAL JOURNAL, 2012, 33 (08) : 819 - 829
  • [7] The automated external defibrillator
    Rho, Robert W.
    Page, Richard L.
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2007, 18 (08) : 896 - 899
  • [8] First appropriate use of automated external defibrillator in an infant
    Bar-Cohen, Y
    Walsh, EP
    Love, BA
    Cecchin, F
    RESUSCITATION, 2005, 67 (01) : 135 - 137
  • [9] Attitudes toward automated external defibrillator use in Japan
    Taniguchi, Takumi
    Omi, Wataru
    Inaba, Hideo
    RESUSCITATION, 2008, 79 (02) : 288 - 291
  • [10] The use of an automated external defibrillator in a victim of car accident
    Puchalski, Bartosz
    Kwasizur, Marek
    Platek, Anna E.
    Szymanski, Filip M.
    KARDIOLOGIA POLSKA, 2014, 72 (12) : 1400 - 1400