Ion trap mass analysis at high pressure: an experimental characterization

被引:40
|
作者
Song, Qingyu [1 ]
Xu, Wei [2 ]
Smith, Scott A. [1 ]
Gao, Liang [1 ]
Chappell, William J. [2 ]
Cooks, R. Graham [1 ,3 ]
Zheng Ouyang [2 ,3 ,4 ]
机构
[1] Purdue Univ, Dept Chem, W Lafayette, IN 47907 USA
[2] Purdue Univ, Sch Elect & Comp Engn, W Lafayette, IN 47907 USA
[3] Purdue Univ, Ctr Analyt Instrumentat Dev, W Lafayette, IN 47907 USA
[4] Purdue Univ, Weldon Sch Biomed Engn, W Lafayette, IN 47907 USA
来源
JOURNAL OF MASS SPECTROMETRY | 2010年 / 45卷 / 01期
基金
美国国家科学基金会;
关键词
rectilinear ion trap (RIT); quadrupole ion trap (QIT); high pressure; mass spectrometry; instrumentation; ELECTROSPRAY-IONIZATION; SPECTROMETRY; PERFORMANCE; PROTEINS; DESIGN; SIMULATION; PRINCIPLES; SEPARATION; INTERFACE; SHIFTS;
D O I
10.1002/jms.1684
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In recent years, it has become increasingly interesting to understand the performance of mass spectrometers at pressures much higher than those employed with conventional operating conditions. This interest has been driven by several influences, including demand for the development of reduced-power miniature mass spectrometers, desire for improved ion transfer into and through mass spectrometers, enhanced-yield preparative mass separations, and mass filtering at the atmospheric pressure interface. In this study, an instrument was configured to allow for the performance characterization of a rectilinear ion trap (RIT) at pressures up to 50 mtorr with air used as the buffer gas. The mass analysis efficiency, mass resolution, isolation efficiency, and collision-induced dissociation (CID) efficiency were evaluated at pressures ranging from 1 to 50 mtorr. The extent of degradation of mass resolution, isolation efficiency and ion stability as functions of pressure were characterized. Also, the optimal resonance ejection conditions were obtained at various pressures. Operations at 50 mtorr demonstrated improved CID efficiency in addition to peak widths of 2 and 5 m/z units (full width at half-maximum, FWHM) for protonated caffeine (m/z 195) and Ultramark (m/z 1521) respectively. Copyright (C) 2009 John Wiley & Sons, Ltd.
引用
收藏
页码:26 / 34
页数:9
相关论文
共 50 条
  • [41] Characterization of a serial array of miniature cylindrical ion trap mass analyzers
    Zheng, OY
    Badman, ER
    Cooks, RG
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (24) : 2444 - 2449
  • [42] Multiple Mass Analysis Using an Ion Trap Array (ITA) Mass Analyzer
    Xiao, Yu
    Chu, Yanqiu
    Ling, Xing
    Ding, Zhengzhi
    Xu, Chongsheng
    Ding, Li
    Ding, Chuan-Fan
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2013, 24 (09) : 1420 - 1427
  • [43] Development and characterization of an ion trap mass spectrometer for the on-line chemical analysis of atmospheric aerosol particles
    Kuerten, Andreas
    Curtius, Joachim
    Helleis, Frank
    Lovejoy, Edward R.
    Borrmann, Stephan
    INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2007, 265 (01) : 30 - 39
  • [44] Mass Analysis Using Collective Interaction of Ions in an Ion Trap
    Zhou, Xiaoyu
    Ouyang, Zheng
    ANALYTICAL CHEMISTRY, 2021, 93 (15) : 5998 - 6002
  • [45] Peptide analysis using ion trap mass spectrometry.
    Stafford, GC
    Schwartz, JC
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 214 : 111 - ANYL
  • [46] Analysis of organometallic compounds using ion trap mass spectrometry
    Dyson, PJ
    McIndoe, JS
    INORGANICA CHIMICA ACTA, 2003, 354 : 68 - 74
  • [47] Sterane biomarker analysis via ion trap mass spectrometry
    Karr, DE
    Walters, CC
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1996, 10 (09) : 1088 - 1092
  • [48] A quadrupole ion trap mass spectrometer for dry microparticle analysis
    Ozdemir, Abdil
    Lin, Jung-Lee
    Gulfen, Mustafa
    Hsiao, Chun-Jen
    Chen, Chung-Hsuan
    ANALYST, 2019, 144 (18) : 5608 - 5616
  • [49] The human erythrocyte proteome - Analysis by ion trap mass spectrometry
    Kakhniashvili, DG
    Bulla, LA
    Goodman, SR
    MOLECULAR & CELLULAR PROTEOMICS, 2004, 3 (05) : 501 - 509
  • [50] Selective ionization for elemental analysis with an ion trap mass spectrometer
    Garrett, AW
    Hemberger, PH
    Nogar, NS
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1995, 50 (14) : 1889 - 1895