Radiation exposure of the head, midface and pelvis in multi-slice CT (MSCT):: Comparison with single-slice CT (SSCT)

被引:11
|
作者
Wedegärtner, U
Thurmann, H
Schmidt, R
Adam, G
机构
[1] Univ Hamburg, Hosp Eppendorf, Abt Diagnost & Intervent Radiol, Radiol Klin, D-20246 Hamburg, Germany
[2] Univ Hamburg, Hosp Eppendorf, Abt Strahlentherapie, D-20246 Hamburg, Germany
关键词
MSCT SSCT; radiation dose; Alderson-Rando Phantom; TLD;
D O I
10.1055/s-2003-37242
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Comparison of the radiation exposure of the head, midface and pelvis in multi-slice CT (MSCT) and single-slice CT (SSCT) for manufacturer-implemented standard protocols. Materials and Methods: An anthropomorphic Alderson-Rando phantom equipped with LiF-thermoluminescent dosimeters in the head, neck and pelvic region was examined with different MSCT and SSCT protocols, and the measured organ doses were compared. Results: In comparison with the SSCT protocols, the MSCT protocols delivered about twice the organ dose to the head and pelvis and about eight times the organ dose to the midface. The comparison indicates that the parameters (slice collimation, mAs, pitch) used for the MSCT protocols deliver increased radiation doses. Conclusions: The current standard MSCT protocols generally lead to higher organ doses to the head, midface and pelvis than the SSCT protocols, raising the question whether using the MSCT protocols recommended by the manufacturer can be justified. The dose parameters should be optimized to achieve an acceptable balance of dose reduction and adequate image quality.
引用
收藏
页码:234 / 238
页数:5
相关论文
共 50 条
  • [21] Principles and applications of multi-slice CT
    Ohnesorge, B
    Flohr, T
    Schaller, S
    Klingenbeck-Regn, K
    Becker, C
    Schöpf, UJ
    Brüning, R
    Reiser, MF
    RADIOLOGE, 1999, 39 (11): : 923 - 931
  • [22] Multi-slice CT image reconstruction
    Hsieh, J.
    MEDICAL PHYSICS, 2006, 33 (06) : 2225 - 2225
  • [23] Optimizing technique for multi-slice CT
    Saini, S
    Dsouza, RV
    EUROPEAN RADIOLOGY, 2003, 13 (Suppl 5) : M21 - M24
  • [24] Optimizing technique for multi-slice CT
    Sanjay Saini
    Roy V. Dsouza
    European Radiology, 2003, 13 : 21 - 24
  • [25] Modelling the Siemens SOMATOM Sensation 64 Multi-Slice CT (MSCT) Scanner
    Amin, A. T. Mohd
    Abd Rahni, A. A.
    10TH INTERNATIONAL SEMINAR ON MEDICAL PHYSICS & 1ST AMDI INTERNATIONAL ONCOLOGY SYMPOSIUM, 2017, 851
  • [26] Radiation exposure in multi-slice CT of the heart (vol 173, pg 295, 2001)
    Cohnen, M
    Poll, L
    Puttmann, C
    Ewen, K
    Modder, U
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2001, 173 (06): : 521 - 521
  • [27] The comparison of radiation dose between C-arm flat-detector CT (DynaCT) and multi-slice CT (MSCT): A phantom study
    Bai, Mei
    Liu, Bin
    Mu, Hongqiu
    Liu, Xianghua
    Jiang, Yuan
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (11) : 3577 - 3580
  • [28] Multi-slice CT artifacts and quality control
    Cody, D.
    MEDICAL PHYSICS, 2006, 33 (06) : 2178 - 2178
  • [29] Multi-slice CT scanner CTDI considerations
    Wu, X
    Nishino, TK
    Barnes, GT
    RADIOLOGY, 2001, 221 : 365 - 365
  • [30] Windmill artifact in multi-slice helical CT
    Silver, M
    Taguchi, K
    Hein, I
    Chiang, BS
    Kazama, M
    Mori, I
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 1918 - 1927