Cryogenic current comparator bridge for quantum Hall resistance ratio measurements

被引:8
|
作者
Kleinschmidt, P [1 ]
Williams, JM [1 ]
Fletcher, NE [1 ]
Janssen, TJBM [1 ]
机构
[1] Natl Phys Lab, Teddington TW11 0LW, Middx, England
关键词
D O I
10.1049/ip-smt:20020758
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
A cryogenic current comparator (CCC) bridge for quantum Hall resistance ratio measurement has been constructed. Compared to previous CCC systems at the National Physical Laboratory, UK, the new system differs in two aspects. Firstly, it uses a type-II CCC, i.e. the ratio windings are on the outside and the detection winding is on the inside. This has the advantage that the CCC can be made very compact and fits into a standard storage Dewar. Secondly, the bridge electronics uses a digital servo and the SQUID feedback loop is disabled during current reversals. The overall relative measurement uncertainty of the system is of the order of 10(-9).
引用
收藏
页码:302 / 304
页数:3
相关论文
共 50 条
  • [1] A quantum Hall cryogenic current comparator resistance bridge
    Jones, K
    Early, MD
    [J]. 2000 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 2000, : 92 - 93
  • [2] SIMULATION OF A QUANTUM HALL CRYOGENIC CURRENT COMPARATOR RESISTANCE BRIDGE
    Lawson, T. B.
    Early, M. D.
    Jones, K.
    [J]. 2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 623 - 624
  • [3] A RESISTANCE RATIO BRIDGE BASED ON A CRYOGENIC CURRENT COMPARATOR FOR MEASURING THE QUANTIZED HALL RESISTANCE
    VANDERWEL, W
    MOOIJ, JE
    HARMANS, CJPM
    ANDRE, JP
    WEIMANN, G
    PLOOG, K
    FOXON, CT
    HARRIS, JJ
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1989, 38 (01) : 54 - 58
  • [4] An automated cryogenic current comparator resistance ratio bridge for routine resistance measurements
    Williams, J. M.
    Janssen, T. J. B. M.
    Rietveld, G.
    Houtzager, E.
    [J]. METROLOGIA, 2010, 47 (03) : 167 - 174
  • [5] AN AUTOMATED CRYOGENIC CURRENT COMPARATOR RESISTANCE RATIO BRIDGE
    WILLIAMS, JM
    HARTLAND, A
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1991, 40 (02) : 267 - 270
  • [6] LOW-NOISE MEASUREMENTS OF THE QUANTIZED HALL RESISTANCE USING AN IMPROVED CRYOGENIC CURRENT COMPARATOR BRIDGE
    DELAHAYE, F
    BOURNAUD, D
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1991, 40 (02) : 237 - 240
  • [7] A cryogenic current comparator bridge for resistance measurements at currents of up to 100 A
    Williams, JM
    Kleinschmidt, P
    [J]. 1998 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS DIGEST, 1998, : 163 - 164
  • [8] A cryogenic current comparator bridge for resistance measurements at currents of up to 100 A
    Williams, JM
    Kleinschmidt, P
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1999, 48 (02) : 375 - 378
  • [9] PROGRESS IN RESISTANCE RATIO MEASUREMENTS USING A CRYOGENIC CURRENT COMPARATOR AT LCIE
    DELAHAYE, F
    REYMANN, D
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 1985, 34 (02) : 316 - 319
  • [10] Quantum Hall Resistance verification based on a Direct Current Comparator Bridge
    Pollarolo, Alessio
    Brown, Duane
    Huang, Shiping
    Wachowicz, Andrew
    Brown, Ryan
    [J]. 2018 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS (CPEM 2018), 2018,