Agreement Between 64-Slice Multidetector CT Angiography and Transthoracic Echocardiography in Detection of Extracardiac Findings of Congenital Heart Disease

被引:6
|
作者
Malik, Adeel Asghar [1 ]
Ahmad, Furqan [1 ]
Amir, Sameera [1 ]
Asgher, Javaid [1 ]
Farooq, Khalid [1 ]
机构
[1] Doctors Hosp & Med Ctr, Dept Radiol, 152 Johar Town, Lahore, Pakistan
关键词
Multi-detector computed tomography; Transthoracic echocardiography; Angiography; CARDIAC-CATHETERIZATION; PREVALENCE;
D O I
10.29271/jcpsp.2019.10.923
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To determine the degree of agreement between multi-detector computed tomography angiography and transthoracic echocardiography in diagnostic evaluation of congenital heart disease with extracardiac findings. Study Design: Descriptive cross-sectional study. Place and Duration of Study: Radiology Department, Doctors Hospital and Medical Centre, Lahore, from May to November 2016. Methodology: Patients with clinical suspicion of cardiovascular malformation were included in the study. All the patients had echocardiography and thoracic computed tomography angiography done to diagnose congenital heart disease. Agreement was labelled in true positive and true negative patients. Results: Computed tomography angiography could detect the extracardiac findings of congenital heart disease in 140 (93.3%) patients, while transthoracic echocardiography in 118 (78.7%) patients. Agreement was detected in 108 (72%) patients. Kappa statistics showed poor agreement (kappa = -0.113). Conclusion: Although transthoracic echocardiography is usually the first line of investigation in evaluation of congenital heart disease; it has its limitations for evaluating congenital heart disease with extracardiac findings, due to intrinsic limitation of the imaged field. Computed tomography angiography has better sensitivity in detecting extracardiac findings of congenital heart disease along with better delineation of anatomy.
引用
收藏
页码:923 / 927
页数:5
相关论文
共 50 条
  • [21] Diagnostic value of 64-slice CT angiography in coronary artery disease: A systematic review
    Sun, Zhonghua
    Lin, ChengHsun
    Davidson, Robert
    Dong, Chiauhuei
    Liao, Yunchan
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 67 (01) : 78 - 84
  • [22] Diagnostic accuracy of lower-dose cardiac CT in evaluating young infants with non-coronary complex congenital heart disease on a 64-slice multidetector CT scanner
    Sakrana, Amal Abdelsattar
    Alharbi, Ibraheem H.
    Elmokadem, Ali H.
    ACTA RADIOLOGICA, 2023, 64 (05) : 2024 - 2032
  • [23] Assessments of Coronary Artery Visibility and Radiation Dose in Infants with Congenital Heart Disease on Cardiac 128-slice CT and on Cardiac 64-slice CT
    Y. Cui
    M. Huang
    J. Zheng
    J. Li
    H. Liu
    C. Liang
    Pediatric Cardiology, 2016, 37 : 135 - 143
  • [24] Assessments of Coronary Artery Visibility and Radiation Dose in Infants with Congenital Heart Disease on Cardiac 128-slice CT and on Cardiac 64-slice CT
    Cui, Y.
    Huang, M.
    Zheng, J.
    Li, J.
    Liu, H.
    Liang, C.
    PEDIATRIC CARDIOLOGY, 2016, 37 (01) : 135 - 143
  • [25] Comparison of myocardial SPECT and 64-slice CT angiography in detection of coronary heart disease: Assessment of functional relevance of CTA using myocardial SPECT
    Cho, Ho Jin
    Kang, Won Jun
    Cho, Arthur
    Seo, Hyo Jung
    Yun, Mijin
    Lee, Jong Doo
    JOURNAL OF NUCLEAR MEDICINE, 2009, 50
  • [26] Prevalence of extravascular collateral findings during 64-slice CT angiography of the abdominal aorta and lower limbs
    Belgrano, M.
    Mucelli, F. Pozzi
    Spadacci, A.
    Pizzolato, R.
    Zappetti, R.
    Cova, M.
    RADIOLOGIA MEDICA, 2010, 115 (06): : 983 - 996
  • [27] Diagnosis of complicated congenital heart diseases in neonates and infants using 64-slice spiral CT
    Ruan, Weiyong
    Yang, Ming
    Gong, Yongchi
    Qiao, Lixing
    Mo, Xuming
    Teng, Gaojun
    SCIENTIFIC RESEARCH AND ESSAYS, 2011, 6 (01): : 146 - 156
  • [28] Intraindividual comparison of gadolinium- and iodine-enhanced 64-slice multidetector CT pulmonary angiography for the detection of pulmonary embolism in a porcine model
    Henes F.O.G.
    Groth M.
    Begemann P.G.C.
    Adam G.
    Regier M.
    Emergency Radiology, 2011, 18 (3) : 189 - 195
  • [29] The feasibility of a 64-slice MDCT for detection of the Adamkiewicz artery: comparison of the detection rate of intravenous injection CT angiography using a 64-slice MDCT versus intra-arterial and intravenous injection CT angiography using a 16-slice MDCT
    Nishii, Tatsuya
    Kono, Atsushi K.
    Negi, Noriyuki
    Hashimura, Hiromi
    Uotani, Kensuke
    Okita, Yutaka
    Sugimura, Kazuro
    INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 : 127 - 133
  • [30] The feasibility of a 64-slice MDCT for detection of the Adamkiewicz artery: comparison of the detection rate of intravenous injection CT angiography using a 64-slice MDCT versus intra-arterial and intravenous injection CT angiography using a 16-slice MDCT
    Tatsuya Nishii
    Atsushi K. Kono
    Noriyuki Negi
    Hiromi Hashimura
    Kensuke Uotani
    Yutaka Okita
    Kazuro Sugimura
    The International Journal of Cardiovascular Imaging, 2013, 29 : 127 - 133