Diagnostic value of 64-slice CT angiography in coronary artery disease: A systematic review

被引:111
|
作者
Sun, Zhonghua [1 ]
Lin, ChengHsun [2 ]
Davidson, Robert [3 ]
Dong, Chiauhuei [2 ]
Liao, Yunchan [2 ]
机构
[1] Curtin Univ Technol, Discipline Med Imaging, Dept Imaging & Appl Phys, Perth, WA 6845, Australia
[2] Cent Taiwan Univ Sci & Technol, Dept Radiol Technol, Taichung, Taiwan
[3] RMIT Univ, Discipline Med Radiat, Bundoora, Vic 3083, Australia
关键词
multislice CT; coronary artery disease; diagnostic value; systematic review;
D O I
10.1016/j.ejrad.2007.07.014
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To per-form a systematic review of the diagnostic value of 64-multislice CT (MSCT) angiography in the detection of coronary artery disease (CAD) when compared to conventional coronary angiography. Materials and methods: A search of PUBMED and MEDLINE databases for English literature was performed. Only studies with at least 10 patients comparing 64-slice MSCT angiography with conventional coronary angiography in the detection of CAD were included. Diagnostic value of MSCT angiography compared to coronary angiography was compared and analysed at segment-, vessel- and patient-based assessment. Results: Fifteen studies met selection criteria and were included for analysis. Pooled sensitivity, specificity, positive predictive value and negative predictive value as well as 95% confidence interval (CI) were 97% (94 and 99%), 88% (79 and 97%), 94% (91 and 97%), and 95% (90 and 99%) for patient-based assessment; 92% (85 and 99%), 92% (85 and 99%), 78% (66 and 91%) and 98% (96 and 99%) for vessel-based assessment; 90% (85 and 94%), 96% (95 and 97%),75%(68 and 82%) and 98% (98 and 99%) for segment-based assessment, respectively. No significant difference was found in the diagnostic accuracy of 64-slice CT in the detection of CAD when comparison was performed either among four main coronary arteries, or between proximal and middle or distal segments (P > 0.05). Conclusion: Our results showed that 64-slice CT angiography has a high-diagnostic value in the detection of CAD. Severe coronary artery calcification seems to be the major factor affecting the visualisation and assessment. (c) 2007 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:78 / 84
页数:7
相关论文
共 50 条
  • [1] 64-slice CT for diagnosis of coronary artery disease: A systematic review
    Stein, Paul D.
    Yaekoub, Abdo Y.
    Matta, Fadi
    Sostman, H. Dirk
    [J]. AMERICAN JOURNAL OF MEDICINE, 2008, 121 (08): : 715 - 725
  • [2] 64-slice CT angiography for the detection of coronary artery stenoses
    Carol Lovegrove
    [J]. Nature Clinical Practice Cardiovascular Medicine, 2006, 3 (1): : 7 - 7
  • [3] Diagnostic accuracy of coronary angiography using 64-slice computed tomography in coronary artery disease
    Yang, Fu-Bin
    Guo, Wan-Liang
    Sheng, Mao
    Sun, Ling
    Ding, Yue-Yue
    Xu, Qiu-Qin
    Xu, Ming-Guo
    Lv, Hai-Tao
    [J]. SAUDI MEDICAL JOURNAL, 2015, 36 (10) : 1156 - 1162
  • [4] Review: 64-slice computed tomography coronary angiography accurately diagnoses coronary artery disease
    Lauer, Michael S.
    [J]. ANNALS OF INTERNAL MEDICINE, 2008, 149 (08)
  • [5] Association of cardiac events with coronary artery disease detected by 64-slice or greater coronary CT angiography: A systematic review and meta-analysis
    Habib, Phillip J.
    Green, Jacinta
    Butterfield, Ryan C.
    Kuntz, Gretchen M.
    Murthy, Raguveer
    Kraemer, Dale F.
    Percy, Robert F.
    Miller, Alan B.
    Strom, Joel A.
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 2013, 169 (02) : 112 - 120
  • [6] Comparison of 64-slice computed tomography angiography and coronary angiography for the detection and assessment of coronary artery disease in patients with angina: A systematic review
    Powell, H.
    Cosson, P.
    [J]. RADIOGRAPHY, 2013, 19 (02) : 168 - 175
  • [7] Coronary 64-slice CT angiography predicts outcome in patients with known or suspected coronary artery disease
    Gaemperli, Oliver
    Valenta, Ines
    Schepis, Tiziano
    Husmann, Lars
    Scheffel, Hans
    Desbiolles, Lotus
    Leschka, Sebastian
    Alkadhi, Hatem
    Kaufmann, Philipp A.
    [J]. EUROPEAN RADIOLOGY, 2008, 18 (06) : 1162 - 1173
  • [8] Diagnostic accuracy of multicletector 64-slice CT coronary angiography in assessing patency of coronary artery bypass grafts
    Jabara, Refat
    Chronos, Nicolas
    Klein, Larry
    Eisenberg, Steve
    Allen, Rebecca
    Bradford, Shannon
    Frohwein, Stephen
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 150A - 150A
  • [9] Coronary 64-slice CT angiography predicts outcome in patients with known or suspected coronary artery disease
    Oliver Gaemperli
    Ines Valenta
    Tiziano Schepis
    Lars Husmann
    Hans Scheffel
    Lotus Desbiolles
    Sebastian Leschka
    Hatem Alkadhi
    Philipp A. Kaufmann
    [J]. European Radiology, 2008, 18 : 1162 - 1173
  • [10] Diagnostic accuracy of multidetector 64-slice CT coronary angiography in assessing patency of coronary artery bypass grafts
    Jabara, Refat
    Klein, Larry
    Chronos, Nicolas
    Allen, Rebecca
    Bradford, Shannon
    Frohwein, Stephen
    [J]. CIRCULATION, 2006, 114 (18) : 693 - 693