Optical coefficient-based multivariate calibration on near-infrared spectroscopy

被引:8
|
作者
Shi, Zhenqi [1 ]
Cogdill, Robert P. [2 ]
Martens, Harald [3 ]
Anderson, Carl A. [1 ]
机构
[1] Duquesne Univ, Grad Sch Pharmaceut Sci, Pittsburgh, PA 15282 USA
[2] Univ Nebraska, Coll Engn, Lincoln, NE 68588 USA
[3] Norwegian Univ Life Sci, Nofima Mat AS & CIGENE IMT, As, Norway
关键词
near-infrared spectroscopy; multivariate calibration; net analyte signal; generalized least square; synthetic calibration; absorption coefficients; reduced scattering coefficients; MULTIPLICATIVE SIGNAL CORRECTION; PREPROCESSING METHODS; PHOTON MIGRATION; SCATTERING; SPECTRA; FIGURES; MERIT;
D O I
10.1002/cem.1301
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The time and expense of calibration development limit the feasibility of NIR spectroscopy for many industrial applications, with a major portion of the costs being related to creation of a sufficient set of calibration samples. Net analyte signal (NAS) and generalized least squares (GLS) pre-processing have been proposed in the literature as methods to simplify multivariate calibration by reducing the quantity of calibration samples by orthogonalizing or shrinking interference signals. Synthetic calibration has also been reported as a method to combine interference signals with pure component spectra to generate virtual calibration models, thereby reducing the number of real calibration samples required. The goals of this paper were to (1) compare theoretical and practical differences between NAS and GLS pre-processing and (2) explore the potential of simplified NIR calibrations, both empirical and synthetic, constructed using optical coefficient-based signal processing on predicting chemical compositions of pharmaceutical powder mixtures. A reduced calibration dataset including only one pharmaceutical powder mixture composition and pure component spectra was used for both empirical and synthetic calibrations. Absorption and reduced scattering coefficients, obtained from spatially-resolved spectroscopy, were used herein as interference signals in NAS/GLS pre-processing for both calibrations. As a result, NAS and GLS were shown to be equivalent in both theoretical and practical senses. After optical coefficient-based signal processing, simplified calibrations, both empirical and synthetic, were demonstrated to have similar model performance as generic pre-processing methods such as SNV and derivative, while requiring fewer principal components and achieving a lower prediction error. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:288 / 299
页数:12
相关论文
共 50 条
  • [41] Ensemble calibration model of near-infrared spectroscopy based on functional data analysis
    Yu, Shaohui
    Liu, Jing
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2022, 280
  • [42] Operationalizing Maintenance of Calibration Models Based on Near-Infrared Spectroscopy by Knowledge Integration
    Takuya Miyano
    Hiroshi Nakagawa
    Tomoyuki Watanabe
    Hidemi Minami
    Hirokazu Sugiyama
    Journal of Pharmaceutical Innovation, 2015, 10 : 287 - 301
  • [43] Calibration Transfer for Near-Infrared (NIR) Spectroscopy Based on Neighborhood Preserving Embedding
    Chen, Lijuan
    Liu, Dawei
    Zhou, Jiheng
    Bin, Jun
    Li, Zhen
    ANALYTICAL LETTERS, 2021, 54 (06) : 947 - 965
  • [44] Near-Infrared Camera Calibration for Optical Surgical Navigation
    Cai, Ken
    Yang, Rongqian
    Lin, Qinyong
    Liu, Sujuan
    Chen, Huazhou
    Ou, Shanxing
    Huang, Wenhua
    Zhou, Jing
    JOURNAL OF MEDICAL SYSTEMS, 2016, 40 (03) : 1 - 12
  • [45] NEAR-INFRARED OXIMETRY AND NEAR-INFRARED SPECTROSCOPY
    OWENREECE, H
    ELWELL, CE
    FALLON, P
    GOLDSTONE, J
    SMITH, M
    ANAESTHESIA, 1994, 49 (12) : 1102 - 1103
  • [46] Near-Infrared Camera Calibration for Optical Surgical Navigation
    Ken Cai
    Rongqian Yang
    Qinyong Lin
    Sujuan Liu
    Huazhou Chen
    Shanxing Ou
    Wenhua Huang
    Jing Zhou
    Journal of Medical Systems, 2016, 40
  • [47] ASSAY OF THE ACTIVE INGREDIENT OF AN MRI CONTRAST AGENT USING MID-INFRARED AND NEAR-INFRARED SPECTROSCOPY AND MULTIVARIATE CALIBRATION
    HARBORG, E
    KLAEBOE, P
    NIELSEN, CJ
    SJOGREN, CE
    JOURNAL OF MOLECULAR STRUCTURE, 1995, 348 : 139 - 142
  • [48] Validation of model of multivariate calibration: an application to the determination of biodiesel blend levels in diesel by near-infrared spectroscopy
    de Carvalho Rocha, Werickson Fortunato
    Nogueira, Raquel
    Vaz, Boniek Gontigo
    JOURNAL OF CHEMOMETRICS, 2012, 26 (8-9) : 456 - 461
  • [49] Determination of flavonoids and phenolic acids in the extract of bamboo leaves using near-infrared spectroscopy and multivariate calibration
    Lu, Baiyi
    Chen, Jianyang
    Huang, Weisu
    Wu, Di
    Xu, Wei
    Xie, Qing
    Yu, Xiao
    Li, Lanjuan
    AFRICAN JOURNAL OF BIOTECHNOLOGY, 2011, 10 (42): : 8448 - 8455
  • [50] Matrix-enhanced calibration procedure for multivariate calibration models with near-infrared spectra
    Riley, MR
    Arnold, MA
    Murhammer, DW
    APPLIED SPECTROSCOPY, 1998, 52 (10) : 1339 - 1347