Optical coefficient-based multivariate calibration on near-infrared spectroscopy

被引:8
|
作者
Shi, Zhenqi [1 ]
Cogdill, Robert P. [2 ]
Martens, Harald [3 ]
Anderson, Carl A. [1 ]
机构
[1] Duquesne Univ, Grad Sch Pharmaceut Sci, Pittsburgh, PA 15282 USA
[2] Univ Nebraska, Coll Engn, Lincoln, NE 68588 USA
[3] Norwegian Univ Life Sci, Nofima Mat AS & CIGENE IMT, As, Norway
关键词
near-infrared spectroscopy; multivariate calibration; net analyte signal; generalized least square; synthetic calibration; absorption coefficients; reduced scattering coefficients; MULTIPLICATIVE SIGNAL CORRECTION; PREPROCESSING METHODS; PHOTON MIGRATION; SCATTERING; SPECTRA; FIGURES; MERIT;
D O I
10.1002/cem.1301
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The time and expense of calibration development limit the feasibility of NIR spectroscopy for many industrial applications, with a major portion of the costs being related to creation of a sufficient set of calibration samples. Net analyte signal (NAS) and generalized least squares (GLS) pre-processing have been proposed in the literature as methods to simplify multivariate calibration by reducing the quantity of calibration samples by orthogonalizing or shrinking interference signals. Synthetic calibration has also been reported as a method to combine interference signals with pure component spectra to generate virtual calibration models, thereby reducing the number of real calibration samples required. The goals of this paper were to (1) compare theoretical and practical differences between NAS and GLS pre-processing and (2) explore the potential of simplified NIR calibrations, both empirical and synthetic, constructed using optical coefficient-based signal processing on predicting chemical compositions of pharmaceutical powder mixtures. A reduced calibration dataset including only one pharmaceutical powder mixture composition and pure component spectra was used for both empirical and synthetic calibrations. Absorption and reduced scattering coefficients, obtained from spatially-resolved spectroscopy, were used herein as interference signals in NAS/GLS pre-processing for both calibrations. As a result, NAS and GLS were shown to be equivalent in both theoretical and practical senses. After optical coefficient-based signal processing, simplified calibrations, both empirical and synthetic, were demonstrated to have similar model performance as generic pre-processing methods such as SNV and derivative, while requiring fewer principal components and achieving a lower prediction error. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:288 / 299
页数:12
相关论文
共 50 条
  • [21] Evaluation of diesel exhaust fluid (DEF) using near-infrared spectroscopy and multivariate calibration
    de Franca, Higor Henrique
    da Silva, Neirivaldo Cavalcante
    Honorato, Fernanda Araujo
    MICROCHEMICAL JOURNAL, 2019, 150
  • [22] TRANSFER OF CALIBRATION FUNCTION IN NEAR-INFRARED SPECTROSCOPY
    FORINA, M
    DRAVA, G
    ARMANINO, C
    BOGGIA, R
    LANTERI, S
    LEARDI, R
    CORTI, P
    CONTI, P
    GIANGIACOMO, R
    GALLIENA, C
    BIGONI, R
    QUARTARI, I
    SERRA, C
    FERRI, D
    LEONI, O
    LAZZERI, L
    CHEMOMETRICS AND INTELLIGENT LABORATORY SYSTEMS, 1995, 27 (02) : 189 - 203
  • [23] Optical and near-infrared spectroscopy of Cygnus A
    Thornton, RJ
    Stockton, A
    Ridgway, SE
    ASTRONOMICAL JOURNAL, 1999, 118 (04): : 1461 - 1467
  • [24] Calibration of somatic cell count in milk based on near-infrared spectroscopy
    Pravdova, V
    Walczak, B
    Massart, DL
    Kawano, S
    Toyoda, K
    Tsenkova, R
    ANALYTICA CHIMICA ACTA, 2001, 450 (1-2) : 131 - 141
  • [25] USE OF INDIRECT MULTIVARIATE CALIBRATION FOR QUALITY-CONTROL OF AGRICULTURAL PRODUCTS BY NEAR-INFRARED SPECTROSCOPY
    PUCHWEIN, G
    EIBELHUBER, A
    MIKROCHIMICA ACTA, 1986, 2 (1-6) : 43 - 51
  • [26] Detection of Organic Acids and pH of Fruit Vinegars Using Near-Infrared Spectroscopy and Multivariate Calibration
    Liu, Fei
    He, Yong
    Wang, Li
    Sun, Guangming
    FOOD AND BIOPROCESS TECHNOLOGY, 2011, 4 (08) : 1331 - 1340
  • [27] Simultaneous Determination of Several Fiber Contents in Blended Fabrics by Near-Infrared Spectroscopy and Multivariate Calibration
    Chen, Hui
    Lin, Zan
    Tan, Chao
    INTERNATIONAL JOURNAL OF CHEMICAL ENGINEERING, 2019, 2019
  • [28] Outlier detection in the ethylene content determination in propylene copolymer by near-infrared spectroscopy and multivariate calibration
    Macho, S
    Sales, F
    Callao, MP
    Larrechi, MS
    Rius, FX
    APPLIED SPECTROSCOPY, 2001, 55 (11) : 1532 - 1536
  • [29] Blend uniformity end-point determination using near-infrared spectroscopy and multivariate calibration
    Sulub, Yusuf
    Konigsberger, Michele
    Cheney, James
    JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 55 (03) : 429 - 434
  • [30] Application of Wavelet Component Selection and Orthogonal Signal Correction in the Multivariate Calibration by Near-Infrared Spectroscopy
    Peng, Dan
    Ji, Junmin
    Li, Xia
    Dong, Kaina
    ADVANCED RESEARCH ON COMPUTER SCIENCE AND INFORMATION ENGINEERING, PT I, 2011, 152 : 374 - 380