Optical coefficient-based multivariate calibration on near-infrared spectroscopy

被引:8
|
作者
Shi, Zhenqi [1 ]
Cogdill, Robert P. [2 ]
Martens, Harald [3 ]
Anderson, Carl A. [1 ]
机构
[1] Duquesne Univ, Grad Sch Pharmaceut Sci, Pittsburgh, PA 15282 USA
[2] Univ Nebraska, Coll Engn, Lincoln, NE 68588 USA
[3] Norwegian Univ Life Sci, Nofima Mat AS & CIGENE IMT, As, Norway
关键词
near-infrared spectroscopy; multivariate calibration; net analyte signal; generalized least square; synthetic calibration; absorption coefficients; reduced scattering coefficients; MULTIPLICATIVE SIGNAL CORRECTION; PREPROCESSING METHODS; PHOTON MIGRATION; SCATTERING; SPECTRA; FIGURES; MERIT;
D O I
10.1002/cem.1301
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The time and expense of calibration development limit the feasibility of NIR spectroscopy for many industrial applications, with a major portion of the costs being related to creation of a sufficient set of calibration samples. Net analyte signal (NAS) and generalized least squares (GLS) pre-processing have been proposed in the literature as methods to simplify multivariate calibration by reducing the quantity of calibration samples by orthogonalizing or shrinking interference signals. Synthetic calibration has also been reported as a method to combine interference signals with pure component spectra to generate virtual calibration models, thereby reducing the number of real calibration samples required. The goals of this paper were to (1) compare theoretical and practical differences between NAS and GLS pre-processing and (2) explore the potential of simplified NIR calibrations, both empirical and synthetic, constructed using optical coefficient-based signal processing on predicting chemical compositions of pharmaceutical powder mixtures. A reduced calibration dataset including only one pharmaceutical powder mixture composition and pure component spectra was used for both empirical and synthetic calibrations. Absorption and reduced scattering coefficients, obtained from spatially-resolved spectroscopy, were used herein as interference signals in NAS/GLS pre-processing for both calibrations. As a result, NAS and GLS were shown to be equivalent in both theoretical and practical senses. After optical coefficient-based signal processing, simplified calibrations, both empirical and synthetic, were demonstrated to have similar model performance as generic pre-processing methods such as SNV and derivative, while requiring fewer principal components and achieving a lower prediction error. Copyright (C) 2010 John Wiley & Sons, Ltd.
引用
收藏
页码:288 / 299
页数:12
相关论文
共 50 条
  • [2] Ensemble of extreme learning machines for multivariate calibration of near-infrared spectroscopy
    Chen, Hui
    Tan, Chao
    Lin, Zan
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2020, 229
  • [3] CLASSIFICATION OF BRAZILIAN COFFEE USING NEAR-INFRARED SPECTROSCOPY AND MULTIVARIATE CALIBRATION
    Santos, Klecia M.
    Moura, Maria F. V.
    Azevedo, Francisco G.
    Lima, Kassio M. G.
    Raimundo, Ivo M., Jr.
    Pasquini, C.
    ANALYTICAL LETTERS, 2012, 45 (07) : 774 - 781
  • [4] Rapid Determination of Phosphogypsum in Soil Based by Infrared (IR) and Near-Infrared (NIR) Spectroscopy with Multivariate Calibration
    Zhou, Bo
    Liang, Yan-Mei
    Bin, Jun
    Ding, Meng-Jiao
    Yang, Min
    Kang, Chao
    ANALYTICAL LETTERS, 2023, 56 (12) : 1962 - 1976
  • [5] INFRARED NEAR-INFRARED SPECTROMETRY AND CHEMOMETRY - MULTIVARIATE CALIBRATION
    MENARDO, C
    ANALUSIS, 1993, 21 (10) : M32 - M34
  • [6] Ensemble Multivariate Calibration Based on Mutual Information for Food Analysis Using Near-Infrared Spectroscopy
    Tan, Chao
    Wang, Jinyue
    Qin, Xin
    Li, Menglong
    ANALYTICAL LETTERS, 2010, 43 (16) : 2640 - 2651
  • [7] Nonlinear calibration for near-infrared spectroscopy
    Dadhe, K
    CHEMICAL ENGINEERING & TECHNOLOGY, 2004, 27 (09) : 946 - 950
  • [8] Multivariate calibration modeling of liver oxygen saturation using near-infrared spectroscopy
    Cingo, NA
    Soller, BR
    Puyana, JC
    BIOMEDICAL DIAGNOSTIC, GUIDANCE, AND SURGICAL-ASSIST SYSTEMS II, 2000, 3911 : 230 - 236
  • [9] Quantifying several adulterants of notoginseng powder by near-infrared spectroscopy and multivariate calibration
    Chen, Hui
    Tan, Chao
    Lin, Zan
    Li, Hongjin
    SPECTROCHIMICA ACTA PART A-MOLECULAR AND BIOMOLECULAR SPECTROSCOPY, 2019, 211 : 280 - 286
  • [10] Determination of Alcohol Content in Beers of Different Styles Based on Portable Near-Infrared Spectroscopy and Multivariate Calibration
    Ana Carolina da Costa Fulgêncio
    Glaucimar Alex Passos Resende
    Marden Claret Fontoura Teixeira
    Bruno Gonçalves Botelho
    Marcelo Martins Sena
    Food Analytical Methods, 2022, 15 : 307 - 316