Fast detection of open-switch fault in cascaded H-bridge multilevel converter

被引:1
|
作者
Shahbazi, M. [1 ]
Zolghadri, M. R. [1 ]
Khodabandeh, M. [1 ]
Ouni, S. [1 ]
机构
[1] Sharif Univ Technol, CEPSMC, POB 11155-8639, Tehran, Iran
基金
美国国家科学基金会;
关键词
Power-switch fault detection; Open-switch fault; Multilevel converter; Cascaded H-bridge converter Insulated Gate Bipolar Transistor (IGBT); VOLTAGE; SYSTEM; PWM; DIAGNOSIS; STRATEGY; RECONFIGURATION; INVERTERS; NETWORK;
D O I
10.24200/sci.2017.4371
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Cascaded H-bridge converter has been utilized recently in different high-power applications due to its modular and simple structure. In order to have a balanced operation after a fault occurrence in this converter, it is necessary to detect the switch fault and its location. In this paper, a fast power-switch fault detection method is presented to identify a fault and its location. Only one voltage measurement per phase is required by this method, and the fault detection is faster compared to the existing methods. Moreover, it is suitable for implementation on an FPGA device due to the use of simple math, relational, and state machine blocks. The proposed method is verified by computer simulations and FPGA-based experimental tests. (C) 2018 Sharif University of Technology. All rights reserved.
引用
收藏
页码:1561 / 1570
页数:10
相关论文
共 50 条
  • [41] Cascaded H-Bridge Multilevel Converter for Electric Vehicle Speed Control
    Kere, Lamoussa Jacques
    Doumbia, Mamadou L.
    Kelouwani, Sousso
    Agbossou, Kodjo
    [J]. 2015 IEEE VEHICLE POWER AND PROPULSION CONFERENCE (VPPC), 2015,
  • [42] Cascaded H-bridge Multilevel Converter for Grid Connection of Photovoltaic System
    Huang, Juan
    Zheng, Changbao
    Hu, Cungang
    [J]. PROCEEDINGS OF THE 2015 10TH IEEE CONFERENCE ON INDUSTRIAL ELECTRONICS AND APPLICATIONS, 2015, : 1846 - 1850
  • [43] A Generalized Switch Fault Diagnosis for Cascaded H-Bridge Multilevel Inverters Using Mean Voltage Prediction
    Anand, Anjali
    Vinayak, Akhil B.
    Raj, Nithin
    Jagadanand, G.
    George, Saly
    [J]. IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2020, 56 (02) : 1563 - 1574
  • [44] Diagnosis of open-circuit fault of switch tube of cascaded H-bridge photovoltaic inverter
    Wang F.
    Chen T.
    Dou S.
    Weng S.
    [J]. Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2022, 43 (05): : 187 - 192
  • [45] A Fault-Tolerant Hybrid Cascaded H-Bridge Multilevel Inverter
    Mhiesan, Haider
    Wei, Yuqi
    Siwakoti, Yam P.
    Mantooth, H. Alan
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2020, 35 (12) : 12702 - 12715
  • [46] An Improved Fault-Tolerant Cascaded H-bridge Multilevel Inverter
    Jakkula, Swamy
    Nakka, Jayaram
    Kishore, P. S. V.
    Haider, Sukanta
    Rajesh, Jami
    [J]. 2022 IEEE INTERNATIONAL CONFERENCE ON POWER ELECTRONICS, DRIVES AND ENERGY SYSTEMS, PEDES, 2022,
  • [47] Fault-tolerant design for multilevel cascaded H-bridge inverter
    Zang, Y
    Wang, X
    Xu, B
    Lin, JQ
    [J]. ICEMI 2005: Conference Proceedings of the Seventh International Conference on Electronic Measurement & Instruments, Vol 8, 2005, : 259 - 263
  • [48] Open-Switch Fault Detection In Three-Phase Symmetrical Cascaded Multilevel Inverter Using Conducted Disturbances
    Abari, Ibtissem
    Hamouda, Mahmoud
    Slama, Jaleleddine Ben Hadj
    [J]. 2018 15TH INTERNATIONAL MULTI-CONFERENCE ON SYSTEMS, SIGNALS AND DEVICES (SSD), 2018, : 77 - 82
  • [49] IGBT Open-Circuit Fault Analysis and Fault-Tolerant Method for Cascaded H-Bridge Converter
    Zhao N.
    Zheng Z.
    Liu J.
    Li C.
    Li Y.
    [J]. Diangong Jishu Xuebao/Transactions of China Electrotechnical Society, 2023, 38 (06): : 1608 - 1619
  • [50] Wavelet-Based Open Switch Fault Diagnosis in Cascaded H-Bridge Multilevel Inverter-fed Induction Motor Drive
    Anand, Anjali
    Raj, Nithin
    George, Saly
    Jagadanand, G.
    [J]. TENCON 2017 - 2017 IEEE REGION 10 CONFERENCE, 2017, : 545 - 550