Sheathless microflow cytometer utilizing two bulk standing acoustic waves

被引:10
|
作者
Wang, Ce [1 ,2 ]
Ma, Yuting [2 ]
Chen, Zhongxiang [2 ]
Wu, Yunliang [2 ]
Song, Feifei [2 ]
Qiu, Jianping [3 ]
Shi, Mengdie [3 ]
Wu, Xiaodong [1 ,2 ]
机构
[1] Univ Sci & Technol China, Sch Biomed Engn Suzhou, Div Life Sci & Med, Suzhou 215163, Jiangsu, Peoples R China
[2] Chinese Acad Sci, Suzhou Inst Biomed Engn & Technol, CAS Key Lab Bio Med Diagnost, 88 Keling Rd, Suzhou 215163, Jiangsu, Peoples R China
[3] Nanjing Med Univ, Affiliated Suzhou Hosp, Gusu Sch, Suzhou Municipal Hosp, Suzhou, Jiangsu, Peoples R China
基金
中国博士后科学基金;
关键词
microflow cytometer; piezoelectric transducer; 3D focusing; bulk acoustic wave; SINGLE-STREAM; FLOW; DEVICE;
D O I
10.1002/cyto.a.24362
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
In recent years, microflow cytometry has become a popular research field because of its potential to provide low-cost and disposable chips for complex cell analyses. Herein, we demonstrate a sheathless microflow cytometer which integrates a bulk standing acoustic wave based microchip capable of three dimensional cell focusing. Flow cytometry was successfully demonstrated using this system with a coefficient of variation (CV) of 2.16% with standard calibration beads. The sensitivities calibrated by rainbow beads are 518 MEFL in fluorescein Isothiocyanate (FITC) channel and 264 MEPE in P-phycoerythrin (PE) channels, respectively. The linearities are more than 99% in both channels. The capability of the proposed microflow cytometer is further demonstrated by immunologically labeled leukocytes differentiation in blood. This acoustic-based microflow cytometer did not require any sheath flows or complex structures and can be mass produced. Because of the simple fluid channel, the chip can be easily made pipeless, disposable for applications requiring no cross contamination. Moreover, with the gentle and bio-compatible acoustic waves used, this technique is expected to maintain the viability of cells and other bioparticles.
引用
收藏
页码:987 / 998
页数:12
相关论文
共 50 条
  • [31] Acoustic streaming generated by standing waves in two-dimensional channels of arbitrary width
    Hamilton, MF
    Ilinskii, YA
    Zabolotskaya, EA
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2003, 113 (01): : 153 - 160
  • [32] Characteristics of acoustic standing waves in fluidized beds
    Herrera, CA
    Levy, EK
    Ochs, J
    AICHE JOURNAL, 2002, 48 (03) : 503 - 513
  • [33] Ignition of fuel mixtures by standing acoustic waves
    Vainshtein, P
    Gutfinger, C
    Pneuli, D
    COMBUSTION AND FLAME, 1999, 118 (03) : 370 - 380
  • [34] Numerical simulation of acoustic streaming in standing waves
    Delis, A. I.
    Mandikas, V.
    Guillard, H.
    COMPUTERS & MATHEMATICS WITH APPLICATIONS, 2023, 152 : 199 - 220
  • [35] Acoustic Standing Waves: A Battle Between Models
    Kok, Karel
    Boczianowski, Franz
    PHYSICS TEACHER, 2021, 59 (03): : 181 - 184
  • [36] Standing acoustic waves imaged by a nanomechanical resonator
    Beil, FW
    Blick, RH
    Wixforth, A
    PHYSICA E-LOW-DIMENSIONAL SYSTEMS & NANOSTRUCTURES, 2004, 21 (2-4): : 1106 - 1110
  • [37] Acoustic streaming in Maxwell fluids generated by standing waves in two-dimensional microchannels
    Vargas, C.
    Campos-Silva, I
    Mendez, F.
    Arcos, J.
    Bautista, O.
    JOURNAL OF FLUID MECHANICS, 2022, 933
  • [38] Acoustic streaming generated by standing waves in two-dimensional channels of arbitrary width
    Hamilton, Mark F.
    Ilinskii, Yurii A.
    Zabolotskaya, Evgenia A.
    Journal of the Acoustical Society of America, 2003, 113 (01): : 153 - 160
  • [39] Precise and programmable manipulation of microbubbles by two-dimensional standing surface acoustic waves
    Meng, Long
    Cai, Feiyan
    Chen, Juanjuan
    Niu, Lili
    Li, Yanming
    Wu, Junru
    Zheng, Hairong
    APPLIED PHYSICS LETTERS, 2012, 100 (17)
  • [40] GRATING ACOUSTIC SCANNER USING BULK ACOUSTIC-WAVES
    CHEN, WH
    LEAN, EG
    ULTRASONIC IMAGING, 1980, 2 (02) : 189 - 189