Influence of patient's physiologic factors and immobilization choice with stereotactic body radiotherapy for upper lung tumors

被引:12
|
作者
Sio, Terence T. [1 ]
Jensen, Andrew R. [1 ]
Miller, Robert C. [1 ]
Santos, Luis E. Fong de los [1 ]
Hallemeier, Christopher L. [1 ]
Foster, Nathan R. [2 ]
Park, Sean S. [1 ]
Bauer, Heather J. [1 ]
Chang, Kenneth [1 ]
Garces, Yolanda I. [1 ]
Olivier, Kenneth R. [1 ]
机构
[1] Mayo Clin, Dept Radiat Oncol, Rochester, MN 55905 USA
[2] Mayo Clin, Div Biomed Stat & Informat, Rochester, MN 55905 USA
来源
关键词
body mass index; immobilization; pulmonary function test; stereotactic body radiation therapy; upper lung tumors; MEDICALLY INOPERABLE PATIENTS; RADIATION-THERAPY; PULMONARY-FUNCTION; CANCER; METASTASES; FRACTIONS; MOVEMENT; GUIDANCE; POSITION; SIZE;
D O I
10.1120/jacmp.v15i5.4931
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
The purpose of the present study was to compare the impact of pulmonary function, body habitus, and stereotactic body radiation therapy (SBRT) immobilization on setup and reproducibility for upper lung tumor. From 2008 through 2011, our institution's prospective SBRT database was searched for patients with upper lung tumors. Two SBRT immobilization strategies were used: full-length BodyFIX and thermoplastic S-frame. At simulation, free-breathing, four-dimensional computed tomography was performed. For each treatment, patients were set up to isocenter with in-room lasers and skin tattoos. Shifts from initial and subsequent couch positions with cone-beam computed tomography (CBCT) were analyzed. Accounting for setup uncertainties, institutional tolerance of CBCT-based shifts for treatment was 2, 2, and 4 mm in left-right, anterior-posterior, and cranial-caudal directions, respectively; shifts exceeding these limits required reimaging. Each patient's pretreatment pulmonary function test was recorded. A multistep, multivariate linear regression model was performed to elucidate intervariable dependency for three-dimensional calculated couch shift parameters. BodyFIX was applied to 76 tumors and S-frame to 17 tumors. Of these tumors, 41 were non-small cell lung cancer and 15 were metastatic from other sites. Lesions measured < 1 (15%), 1.1 to 2 (50%), 2.1 to 3 (25%), and > 3 (11%) cm. Errors from first shifts of first fractions were significantly less with S-frame than BodyFIX (p < 0.001). No difference in local control (LC) was found between S-frame and BodyFIX (p = 0.35); two-year LC rate was 94%. Multivariate modeling confirmed that the ratio of forced expiratory volume in the first second of expiration to forced vital capacity, body habitus, and the immobilization device significantly impacted couch shift errors. For upper lung tumors, initial setup was more consistent with S-frame than BodyFIX, resulting in fewer CBCT scans. Patients with obese habitus and poor lung function had more SBRT setup uncertainty; however, outcome and probability for LC remained excellent.
引用
收藏
页码:235 / 245
页数:11
相关论文
共 50 条
  • [31] Stereotactic body radiotherapy for lung tumors: Dosimetric analysis and clinical outcome
    Talapatra, Kaustav
    Majumder, Dipanjan
    Chadha, Pranav
    Shaju, P.
    Goyle, Sandeep
    Smruti, B. K.
    Mistry, Rajesh
    INDIAN JOURNAL OF CANCER, 2018, 55 (02) : 170 - 175
  • [32] Safety of Stereotactic Body Radiotherapy for Central, Ultracentral, and Paramediastinal Lung Tumors
    Daly, Megan
    Novak, Jennifer
    Monjazeb, Arta
    JOURNAL OF THORACIC ONCOLOGY, 2017, 12 (01) : S1066 - S1066
  • [33] Oncological Results and Toxicities of Stereotactic Body Radiotherapy in Ultracentral Lung Tumors
    Yakar, Melek
    Etiz, Durmus
    UHOD-ULUSLARARASI HEMATOLOJI-ONKOLOJI DERGISI, 2024, 34 (02): : 84 - 92
  • [34] EVALUATION OF IMMOBILIZATION TECHNIQUES IN STEREOTACTIC BODY RADIOTHERAPY FOR EARLY STAGE LUNG CANCERS AND LUNG METASTASES
    Murland, Shannah
    Paterson, Pamela
    RADIOTHERAPY AND ONCOLOGY, 2021, 163 : S70 - S70
  • [35] Influence of respiration on dose calculation in stereotactic body radiotherapy of the lung
    Yamazaki R.
    Onimaru R.
    Katoh N.
    Inoue T.
    Nishioka T.
    Shirato H.
    Date H.
    Radiological Physics and Technology, 2014, 7 (2) : 284 - 289
  • [36] A comparison of two immobilization systems for stereotactic body radiation therapy of lung tumors
    Han, Kathy
    Cheung, Patrick
    Basran, Parminder S.
    Poon, Ian
    Yeung, Latifa
    Lochray, Fiona
    RADIOTHERAPY AND ONCOLOGY, 2010, 95 (01) : 103 - 108
  • [37] Stereotactic body radiotherapy in patients with multiple lung tumors: a focus on lung dosimetric constraints
    Milano, Michael T.
    Mihai, Alina
    Kang, John
    Singh, Deepinder P.
    Verma, Vivek
    Qiu, Haoming
    Chen, Yuhchyau
    Kong, Feng-Ming
    EXPERT REVIEW OF ANTICANCER THERAPY, 2019, 19 (11) : 959 - 969
  • [38] Setup accuracy and dose attenuation of a wooden immobilization system for lung stereotactic body radiotherapy
    Nitta, Yuya
    Ueda, Yoshihiro
    Murata, Seiya
    Isono, Masaru
    Ohira, Shingo
    Masaoka, Akira
    Inui, Shoki
    Washio, Hayate
    Yoshinaka, Reimi
    Sagawa, Tomohiro
    Miyazaki, Masayoshi
    Teshima, Teruki
    REPORTS OF PRACTICAL ONCOLOGY AND RADIOTHERAPY, 2022, 27 (05) : 809 - 820
  • [39] PATIENT STABILITY DURING STEREOTACTIC BODY RADIOTHERAPY (SBRT) DELIVERED WITHOUT EXTERNAL IMMOBILIZATION
    Dahele, M.
    Verbakel, W.
    Slotman, B.
    Senan, S.
    RADIOTHERAPY AND ONCOLOGY, 2011, 99 : S568 - S569
  • [40] Outcomes after stereotactic body radiotherapy for lung tumors, with emphasis on comparison of primary lung cancer and metastatic lung tumors
    Yamamoto, Takaya
    Jingu, Keiichi
    Shirata, Yuko
    Koto, Masashi
    Matsushita, Haruo
    Sugawara, Toshiyuki
    Kubozono, Masaki
    Umezawa, Rei
    Abe, Keiko
    Kadoya, Noriyuki
    Ishikawa, Youjirou
    Kozumi, Maiko
    Takahashi, Noriyoshi
    Takeda, Ken
    Takai, Yoshihiro
    BMC CANCER, 2014, 14