Primary stent placement for infrarenal coral reef aortic stenosis

被引:0
|
作者
Donas, K. P. [1 ]
Schoenefeld, T.
Schoenefeld, E.
Torsello, G.
机构
[1] St Franziskus Hosp Munster, Klin Gefasschirurg, D-48145 Munster, Germany
来源
GEFASSCHIRURGIE | 2010年 / 15卷 / 03期
关键词
Infrarenal aortic stenosis; Primary stent placement; Coral reef aorta; TERM FOLLOW-UP; ANGIOPLASTY;
D O I
10.1007/s00772-009-0748-3
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
We report on the outcome of primary stent placement in a 52-year-old patient who suffered from eccentric coral reef infrarenal aortic stenosis. Despite the challenging anatomy for endovascular treatment, with a high risk of aortic rupture, simultaneous implantation of self-expanding and balloon expandable stents was safe and led to improvement in the patient's clinical status, with palpable peripheral pulses after the intervention.
引用
收藏
页码:199 / 201
页数:3
相关论文
共 50 条
  • [21] Dissection of the infrarenal aorta treated by stent graft placement
    Ferko, A
    Krajina, A
    Jon, B
    Lesko, M
    Voboril, Z
    Zizka, J
    EUROPEAN RADIOLOGY, 1998, 8 (02) : 298 - 300
  • [22] Clinical Impact of Isolated Infrarenal Aortic Stenosis
    Malgor, Rafael D.
    Labropoulos, Nicos
    Borge, Marc
    Dias, Celso
    Pappas, Peter
    Tassiopoulos, Apostolos
    JOURNAL OF VASCULAR SURGERY, 2013, 58 (04) : 1156 - 1156
  • [23] Dissection of the infrarenal aorta treated by stent graft placement
    A. Ferko
    A. Krajina
    B. Jon
    M. Lesˇko
    Z. Vobořil
    J. Žizˇka
    European Radiology, 1998, 8 : 298 - 300
  • [24] Aortic Stenting in Symptomatic Infrarenal Aortic Stenosis and Subtotal Aortic Occlusion
    Tatiana, Belyavskaya
    Peter, Kalmar
    Peter, Konstantiniuk
    Anneliese, Baumann
    Tina, Cohnert
    VASCULAR AND ENDOVASCULAR SURGERY, 2019, 53 (04) : 303 - 309
  • [25] Stent placement for aqueductal stenosis
    Lunsford, L. Dade
    Leksell, Dan
    JOURNAL OF NEUROSURGERY-PEDIATRICS, 2021, 27 (04) : 493 - 494
  • [26] Bilateral renal fornix rupture following intraarterial contrast medium application for infrarenal aortic stent placement
    Niggemann, P
    Brehmer, B
    Schuermann, K
    CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 29 (01) : 157 - 159
  • [27] Endovascular stent-graft placement for nonaneurysmal infrarenal aortic rupture: A case report and review of the literature
    Vasquez, J
    Poultsides, GA
    Lorenzo, AC
    Foster, JE
    Drezner, AD
    Gallagher, J
    JOURNAL OF VASCULAR SURGERY, 2003, 38 (04) : 836 - 839
  • [28] Primary stent placement for hepatic artery stenosis after liver transplantation
    Le, Linda
    Terral, William
    Zea, Nicolas
    Bazan, Hernan A.
    Smith, Taylor A.
    Loss, George E.
    Bluth, Edward
    Sternbergh, W. Charles, III
    JOURNAL OF VASCULAR SURGERY, 2015, 62 (03) : 704 - 709
  • [29] Bilateral Renal Fornix Rupture Following Intraarterial Contrast Medium Application for Infrarenal Aortic Stent Placement
    Pascal Niggemann
    Bernhard Brehmer
    Karl Schuermann
    CardioVascular and Interventional Radiology, 2006, 29 : 157 - 159
  • [30] Bioengineering: infrarenal aortic stent graft explantation device
    Hatami, Solyman
    Mathew, Alwin
    Maturi, Vamsi
    Lu, Shannon
    Sears, Nicholas
    Rahimi, Maham
    VASCULAR MEDICINE, 2023, 28 (05) : 518 - 518