摘要
In order to measure optical fiber connectors endface geometry parameters owith a high accuracy, a novel interferometer is proposed. In a Twyman-Green interferometcr, an optical shutter that opens or closes on command is placed between a beam splitter and a reference mirror. When the shutter is open, four interferograms are recorded in sequence with a CCD camera. Then the Carre phase-measurement technique and a new phase unwrapping algorithm are used to obtain the endface profile of the connector being measured. When the shutter is closed, what is captured by the CCD is the image of the fiber connector endface. Hough translation is used to accurately identify the fiber core center in the image. After the endface profile of the fiber connector and the location of the fiber core center are obtained, the endface geometry parameters are obtained by simple calculation. The measurement repeatability of the instrument, developed based on the above method, is as follows: radius(less than or equal to0.05%), apex offset (less than or equal to0.06mum), fiber height(less than or equal to5.5nm), and angle(less than or equal to0.0004degrees). Taking a test sample PC01 as an example, a comparison is made between results measured with the instrument and those measured with Dorc's ZX-1 mini PMS. The differences in radius, apex offset, fiber height and angle are 0.13 %, 3.96%, 4.35% and 3.85%, respectively. Hence the measurement accuracy of the instrument is comparable with that of the Dorc's ZX-1 mini PMS interferometer. The instrument has passed the test performed by the National Measurement and Test Center for East China.
引用
收藏
页码:809 / 814
页数:6
相关论文
共 50 条
  • [41] Optical fiber endface biosensor based on resonances in dielectric waveguide gratings
    Wawro, D
    Tibuleac, S
    Magnusson, R
    Liu, H
    BIOMEDICAL DIAGNOSTIC, GUIDANCE, AND SURGICAL-ASSIST SYSTEMS II, 2000, 3911 : 86 - 94
  • [42] MULTIMODE OPTICAL FIBER INTERFEROMETER
    DANIELSON, BL
    JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1978, 68 (10) : 1384 - 1384
  • [43] MEASUREMENT OF OPTICAL FIBER SENSING PARAMETER USING FBG WITH WDM
    Yan, Huanhuan
    Wang, Li
    Peng, Zhaozhuang
    Hu, Shuyang
    ADVANCED SENSOR SYSTEMS AND APPLICATIONS VII, 2016, 10025
  • [44] Digital holographic microtomography for geometric parameter measurement of optical fiber
    Pan, Zhelang
    Li, Shiping
    Zhong, Jingang
    OPTICAL ENGINEERING, 2013, 52 (03)
  • [45] Parameter measurement and load performance analysis of special optical fiber
    College of Science, Nanjing University of Aeronautics and Astronautics, Nanjing 210016, China
    Zhejiang Daxue Xuebao (Gongxue Ban), 2007, 10 (1647-1649):
  • [46] DOUBLE-BULB OPTICAL FIBER CONNECTOR
    DRAKE, MD
    APPLIED OPTICS, 1982, 21 (15): : 2656 - 2658
  • [47] Design and analysis of a highly stabilised optical fiber Michelson interferometer measurement system
    Xie, Fang
    Ren, Junyu
    Chen, Zhimin
    SENSORS AND ACTUATORS A-PHYSICAL, 2009, 152 (02) : 176 - 181
  • [48] NONLINEAR OPTICAL-FIBER INTERFEROMETER FOR NONDEMOLITIONAL MEASUREMENT OF PHOTON NUMBER.
    Imoto, N.
    Watkins, S.
    Sasaki, Y.
    1600, (61):
  • [49] Optical fiber Fabry-Perot interferometer for arterial pulse waveform measurement
    Martincek I.
    Tarjanyiova G.
    IEEE Sensors Journal, 2024, 24 (16) : 1 - 1
  • [50] The stabilization of a multiplexed optical fiber interferometer system for on-line precision measurement
    Fang Xie
    Chen Zhi Min
    2008 INTERNATIONAL CONFERENCE ON OPTICAL INSTRUMENTS AND TECHNOLOGY: ADVANCED SENSOR TECHNOLOGIES AND APPLICATIONS, 2009, 7157