Interferometer for measurement of optical fiber connector endface geometry parameter

被引:0
|
作者
Lu, YG [1 ]
Wang, XZ [1 ]
Zhong, XH [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Opt & Fine Mech, Shanghai, Peoples R China
关键词
optical measurement; interferometer; phase shift; geometry parameter; optical fiber connector;
D O I
暂无
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
In order to measure optical fiber connectors endface geometry parameters owith a high accuracy, a novel interferometer is proposed. In a Twyman-Green interferometcr, an optical shutter that opens or closes on command is placed between a beam splitter and a reference mirror. When the shutter is open, four interferograms are recorded in sequence with a CCD camera. Then the Carre phase-measurement technique and a new phase unwrapping algorithm are used to obtain the endface profile of the connector being measured. When the shutter is closed, what is captured by the CCD is the image of the fiber connector endface. Hough translation is used to accurately identify the fiber core center in the image. After the endface profile of the fiber connector and the location of the fiber core center are obtained, the endface geometry parameters are obtained by simple calculation. The measurement repeatability of the instrument, developed based on the above method, is as follows: radius(less than or equal to0.05%), apex offset (less than or equal to0.06mum), fiber height(less than or equal to5.5nm), and angle(less than or equal to0.0004degrees). Taking a test sample PC01 as an example, a comparison is made between results measured with the instrument and those measured with Dorc's ZX-1 mini PMS. The differences in radius, apex offset, fiber height and angle are 0.13 %, 3.96%, 4.35% and 3.85%, respectively. Hence the measurement accuracy of the instrument is comparable with that of the Dorc's ZX-1 mini PMS interferometer. The instrument has passed the test performed by the National Measurement and Test Center for East China.
引用
收藏
页码:809 / 814
页数:6
相关论文
共 50 条
  • [21] Positioning method for optical fiber interferometer of absolute distance measurement
    Hong, Haitao
    Yu, Pu
    Ye, Shenghua
    Guangxue Xuebao/Acta Optica Sinica, 2000, 20 (02): : 240 - 244
  • [22] Strain measurement inside of composites by embedded optical fiber interferometer
    Southeast Univ, Nanjing, China
    Fuhe Cailiao Xuebao, 1 (77-80):
  • [23] FIBER-OPTICAL INTERFEROMETER FOR VARIABLE-PRESSURE MEASUREMENT
    BUTUSOV, MM
    ERMAKOVA, NV
    URVANTSEVA, NL
    SHUMILIN, VP
    OPTIKA I SPEKTROSKOPIYA, 1985, 59 (01): : 226 - 228
  • [24] The effect of optical fiber endface surface roughness on light coupling
    Gharbia, YA
    Milton, G
    Katupitiya, J
    OPTICAL FABRICATION, TESTING, AND METROLOGY, 2004, 5252 : 201 - 208
  • [25] Optical connector technologies for optical fiber network
    Abe, Yoshiteru
    Journal of the Institute of Electronics, Information and Communication Engineers, 2015, 98 (09): : 818 - 822
  • [26] Research on Physical Parameter Measurement System of Fiber Fabry-Perot Interferometer
    Li, Yanjun
    Wu, Wenqi
    2018 IEEE INTERNATIONAL CONFERENCE ON MANIPULATION, MANUFACTURING AND MEASUREMENT ON THE NANOSCALE (3M-NANO) - CONFERENCE PROCEEDINGS, 2018, : 377 - 381
  • [27] Fiber physical contact optical connector
    Kobayashi, M
    Iwano, S
    Nagase, R
    Mitachi, S
    NTT REVIEW, 1997, 9 (02): : 72 - 77
  • [28] A single-mode optical fiber interferometer for surface vibration measurement
    Scalise, L
    Di Sante, R
    FIBER OPTIC SENSOR TECHNOLOGY II, 2001, 4204 : 115 - 123
  • [29] Fiber optical Moire interferometer and its application in configuration or deformation measurement
    Sun, WM
    Yuan, LB
    Guan, CY
    ADVANCED MATERIALS AND DEVICES FOR SENSING AND IMAGING, 2002, 4919 : 347 - 354
  • [30] Lensed Plastic Optical Fiber with a Convexo-Concave Fiber Endface for Coupling Laser Diodes With Plastic Optical Fiber
    Tseng, Yih-Tun
    Chang, Shu-Ming
    Huang, Sheng-He
    Cheng, Wood-Hi
    JOURNAL OF MANUFACTURING SCIENCE AND ENGINEERING-TRANSACTIONS OF THE ASME, 2011, 133 (04):