Ion-molecule-reaction mass spectrometer for on-line gas analysis

被引:23
|
作者
Bassi, D [1 ]
Tosi, P
Schlogl, R
机构
[1] INFM, I-38050 Trento, Italy
[2] Univ Trent, Dipartimento Fis, I-38050 Trento, Italy
[3] Max Planck Gesell, Fritz Haber Inst, D-14795 Berlin, Germany
来源
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A | 1998年 / 16卷 / 01期
关键词
D O I
10.1116/1.580957
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We describe an apparatus for ion-molecule-reaction mass spectrometry. It is suitable for on-line gas analysis covering the mass range from 1 to 200 amu with a sensitivity of about 1 ppm. The gas to be analyzed is ionized by reaction with a primary ion beam at low collision energy. A mass-selected ion source allows the fast switching among three primary ions beams (Xe+, Kr+, and CF3I+), covering the recombination energy range from 10.23 to 14.67 eV. Calibration measurements and an example of application to the study of heterogeneous catalysis are presented. (C) 1998 American Vacuum Society.
引用
收藏
页码:114 / 122
页数:9
相关论文
共 50 条
  • [31] A PROGRAMMABLE MAGNETIC FIELD MASS SPECTROMETER WITH ON-LINE DATA PROCESSING
    WASSERBU.GJ
    PAPANAST.DA
    NENOW, EV
    BAUMAN, CA
    TRANSACTIONS-AMERICAN GEOPHYSICAL UNION, 1968, 49 (01): : 350 - +
  • [32] ON-LINE COMPUTER SYSTEM FOR LOW-RESOLUTION MASS SPECTROMETER
    KNUTTI, R
    BUHLER, RE
    CHIMIA, 1970, 24 (12) : 437 - &
  • [33] On the performance of an on-line time-of-flight mass spectrometer for aerosols
    Weiss, M
    Verheijen, PJT
    Marijnissen, JCM
    Scarlett, B
    JOURNAL OF AEROSOL SCIENCE, 1997, 28 (01) : 159 - 171
  • [34] ON-LINE WIRE SPARK CHAMBER SYSTEM USED AS A MASS SPECTROMETER
    GRAVEN, RM
    NEU, FD
    STELLREC.HH
    TORRANO, MA
    ABOLINS, MA
    MCCARTHY, RL
    SMITH, GA
    SMITH, LH
    WICKLUND, AB
    NUCLEAR INSTRUMENTS & METHODS, 1968, 66 (01): : 125 - &
  • [35] Coupling a total absorption spectrometer to the GSI on-line mass separator
    Karny, M
    Nitschke, JM
    Archambault, LF
    Burkard, K
    CanoOtt, D
    Hellstrom, M
    Huller, W
    Kirchner, R
    Lewandowski, S
    Roeckl, E
    Sulik, A
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 1997, 126 (1-4): : 411 - 415
  • [36] Weak interaction studies with an on-line Penning trap mass spectrometer
    Savard, G.
    Barber, R. C.
    Buchinger, F.
    Crawford, J. E.
    Feng, X.
    Gulick, S.
    Hackman, G.
    Hardy, J. C.
    Lee, J. K. P.
    Moore, R. B.
    Sharma, K. S.
    Uusitalo, J.
    NUCLEAR PHYSICS A, 1999, 654 (01) : 961C - 966C
  • [37] Coupling a total absorption spectrometer to the GSI on-line mass separator
    Karny, M.
    Nitschke, J.M.
    Archambault, L.F.
    Burkard, K.
    Cano-Ott, D.
    Hellstrom, M.
    Huller, W.
    Kirchner, R.
    Lewandowski, S.
    Roeckl, E.
    Sulik, A.
    Nuclear Instruments and Methods in Physics Research, Section B: Beam Interactions with Materials and Atoms, 1997, 126 (1-4): : 411 - 415
  • [38] Selected ion flow tube mass spectrometry, SIFT-MS, for on-line trace gas analysis of breath
    Smith, D
    Spanel, P
    BREATH ANALYSIS: FOR CLINICAL DIAGNOSIS AND ATHERAPEUTIC MONITORING, 2005, : 3 - 34
  • [39] On-line transformer gas analysis
    Pyke, S
    PROCEEDINGS OF THE AMERICAN POWER CONFERENCE, VOL 58, PTS I AND II, 1996, 58 : 289 - 292