Ion-molecule-reaction mass spectrometer for on-line gas analysis

被引:23
|
作者
Bassi, D [1 ]
Tosi, P
Schlogl, R
机构
[1] INFM, I-38050 Trento, Italy
[2] Univ Trent, Dipartimento Fis, I-38050 Trento, Italy
[3] Max Planck Gesell, Fritz Haber Inst, D-14795 Berlin, Germany
来源
JOURNAL OF VACUUM SCIENCE & TECHNOLOGY A | 1998年 / 16卷 / 01期
关键词
D O I
10.1116/1.580957
中图分类号
TB3 [工程材料学];
学科分类号
0805 ; 080502 ;
摘要
We describe an apparatus for ion-molecule-reaction mass spectrometry. It is suitable for on-line gas analysis covering the mass range from 1 to 200 amu with a sensitivity of about 1 ppm. The gas to be analyzed is ionized by reaction with a primary ion beam at low collision energy. A mass-selected ion source allows the fast switching among three primary ions beams (Xe+, Kr+, and CF3I+), covering the recombination energy range from 10.23 to 14.67 eV. Calibration measurements and an example of application to the study of heterogeneous catalysis are presented. (C) 1998 American Vacuum Society.
引用
收藏
页码:114 / 122
页数:9
相关论文
共 50 条
  • [21] ION-MOLECULE REACTIONS OF PHOSPHINE IN MASS SPECTROMETER
    HALMANN, M
    PLATZNER, I
    JOURNAL OF PHYSICAL CHEMISTRY, 1967, 71 (13): : 4522 - &
  • [22] Design and performance of an evolved gas analysis ion attachment mass spectrometer
    Takahashi, Seiji
    Tsukagoshi, Masamichi
    Kitahara, Yuki
    Juhasz, Marta
    Fujii, Toshihiro
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (17) : 2625 - 2630
  • [23] ENERGY DEPENDECE FOR REACTION CROSS SECTIONS OF ION-MOLECULE REACTIONS OF CYCLOPROPANE IN MASS SPECTROMETER
    POTTIE, RF
    LORQUET, AJ
    HAMILL, WH
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1962, 84 (04) : 529 - &
  • [24] ON THE TEMPERATURE OF THE GAS IN THE ION SOURCE OF A MASS SPECTROMETER
    TALROSE, VL
    FRANKEVICH, EL
    SOVIET PHYSICS-TECHNICAL PHYSICS, 1956, 1 (03): : 479 - 480
  • [25] On-line analysis of cholrobenzenes by windowless RF discharge signal photon ionization mass spectrometer
    College of Instrumentation & Electrical Engineering, Jilin University, Changchun
    130026, China
    不详
    116023, China
    不详
    100049, China
    J. Chin. Mass Spectrom. Soc., 6 (506-512):
  • [26] On-line automated environmental analysis with ion trap mass spectrometric detection
    Voyksner, RD
    Townsend, JA
    AMERICAN LABORATORY, 2002, 34 (19) : 18 - +
  • [27] ON-LINE HIGH RESOLUTION MASS SPECTROMETER DATA ACQUISITION SYSTEM
    HERRMANN, RA
    MCNEILL, JP
    APPLIED SPECTROSCOPY, 1968, 22 (03) : 240 - &
  • [28] A PROGRAMMABLE MAGNETIC FIELD MASS SPECTROMETER WITH ON-LINE DATA PROCESSING
    WASSERBU.GJ
    PAPANAST.DA
    NENOW, EV
    BAUMAN, CA
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1969, 40 (02): : 288 - &
  • [29] Aerosol mass spectrometer for quantitative on-line sampling of particle composition
    Coe, H.
    Williams, P.I.
    Gallagher, M.W.
    Bower, K.N.
    Choularton, T.W.
    Jayne, J.T.
    Worsnop, D.
    Journal of Aerosol Science, 2000, 31 (SUPPL. 1)
  • [30] On-Line Desalting of Crude Oil in the Source Region of a Fourier Transform Ion Cyclotron Resonance Mass Spectrometer
    Chanthamontri, C. Ken
    Stopford, Andrew P.
    Snowdon, Ryan W.
    Oldenburg, Thomas B. P.
    Larter, Stephen R.
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2014, 25 (08) : 1506 - 1510