Implementation of in-vivo diode dosimetry for intensity modulated radiotherapy as routine patients' quality assurance

被引:0
|
作者
AL-Shareef, Jamal M. [1 ,2 ,3 ]
Attalla, Ehab M. [1 ]
El-Gebaly, Reem H. [2 ]
Deiab, Nashaat A. [1 ]
Abdelmajeed, M. [1 ]
Fathy, Mohamed M. [2 ]
机构
[1] Cairo Univ, Natl Canc Inst, Dept Radiotherapy & Nucl Med, Giza, Egypt
[2] Cairo Univ, Fac Sci, Dept Biophys, Giza, Egypt
[3] Sanaa Univ, Dept Phys, Sanaa, Yemen
关键词
In-vivo dosimetry; In-vitro dosimetry; Diode; IMRT; QA; EXIT DOSE MEASUREMENTS; MOSFET DETECTORS; ENTRANCE; ERRORS;
D O I
10.1016/j.radphyschem.2021.109564
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
The implementation of an in-vivo diode for dose verification of the intensity-modulated radiotherapy (IMRT) during the actual treatment being rare. This work aims to implement in-vivo and in-vitro diode dosimetry for the IMRT technique to verify the accuracy of the dose delivered to the patients undergoing radiation treatment. In total, 279 fields have been investigated for dose verification from 33 cases, including head and neck, prostate, bladder, and breast cancer patients. Additionally, these fields were compared with in-vitro measurements on a perspex phantom. Beforehand, the measurements were tested for an Alderson Rando phantom. In-vivo measurements revealed that 87.1% of the measured doses were within +/- 5% of the calculated doses. Of the other 12.9%, about 11.1% were more than +/- 5% and less +/- 10% and only 1.8% were outside the +/- 10% of the calculated doses. The corresponding fields for in-vitro measurements show that 96.1% of the measured doses within +/- 5% and only 3.9% were outside the +/- 5% of the calculated doses. The results in this study indicated that in-vivo diode dosimetry for IMRT is reliable as a quality assurance (QA) tool in the radiotherapy departments. Moreover, measurements with diodes are a real-time readout during actual treatment compared to the verification tools that have been used for routine IMRT QA. Additionally, the measurements were carried out comfortably and well tolerated by the patients.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Comparison of film dosimetry techniques used for quality assurance of intensity modulated radiation therapy
    Ju, Sang Gyu
    Han, Youngyih
    Kum, Oyeon
    Cheong, Kwang-Ho
    Shin, Eun Hyuk
    Shin, Jung Suk
    Kim, Jin Sung
    Ahn, Yong Chan
    [J]. MEDICAL PHYSICS, 2010, 37 (06) : 2925 - 2933
  • [42] The GLAaS algorithm for portal dosimetry and quality assurance of RapidArc, an intensity modulated rotational therapy
    Giorgia Nicolini
    Eugenio Vanetti
    Alessandro Clivio
    Antonella Fogliata
    Stine Korreman
    Jiri Bocanek
    Luca Cozzi
    [J]. Radiation Oncology, 3
  • [43] IN-VIVO DOSIMETRY USING A DIODE DETECTOR SYSTEM
    PODGORSAK, MB
    BALOG, JP
    SIBATA, CH
    HO, AK
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1995, 32 (02): : 556 - 557
  • [44] Multicentre quality assurance of intensity-modulated radiotherapy planning: Beware the benchmarker
    Back, M.
    Oliver, L.
    Bromley, R.
    Eade, T.
    [J]. JOURNAL OF MEDICAL IMAGING AND RADIATION ONCOLOGY, 2008, 52 (02): : 197 - 197
  • [45] Quality assurance of intensity-modulated radiotherapy treatment planning: a dosimetric comparison
    Altaf, Saima
    Iqbal, Khalid
    Akram, Muhammad
    Buzdar, Saeed A.
    [J]. JOURNAL OF RADIOTHERAPY IN PRACTICE, 2018, 17 (04) : 396 - 402
  • [46] Changes in Patterns of Intensity-modulated Radiotherapy Verification and Quality Assurance in the UK
    Abolaban, F.
    Zaman, S.
    Cashmore, J.
    Nisbet, A.
    Clark, C. H.
    [J]. CLINICAL ONCOLOGY, 2016, 28 (08) : E28 - E34
  • [47] 4D in-vivo dosimetry in radiotherapy
    Cygler, J.
    Saoudi, A.
    Cherpak, A.
    Ding, W.
    Ashton, R.
    [J]. MEDICAL PHYSICS, 2007, 34 (06) : 2402 - 2402
  • [48] Comment on "In vivo diode dosimetry for routine quality assurance in IMRT" -: [Med. Phys. 30, 3118-3123 (2003)]
    Jornet, N
    [J]. MEDICAL PHYSICS, 2004, 31 (06) : 1642 - 1643
  • [49] 4D in-vivo dosimetry in radiotherapy
    Cherpak, A. J.
    Buckley, L.
    Ding, W.
    Ashton, R.
    Cygler, J. E.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2007, 84 : S52 - S52
  • [50] Clinical implementation of intensity modulated radiotherapy
    De Neve, W
    [J]. BRITISH JOURNAL OF CANCER, 2000, 83 : 6 - 6