Treatment of ammonia nitrogen wastewater by membrane distillation using PVDF membranes

被引:4
|
作者
Xia, Qiang [1 ]
Yun, Yanbin [1 ]
Chen, Jinjin [2 ]
Qu, Dan [1 ]
Li, Chunli [3 ]
Zhu, Shouwei [4 ]
机构
[1] Beijing Forestry Univ, Sch Environm Sci & Engn, Beijing 100083, Peoples R China
[2] Beijing Forestry Univ, Sch Landscape Architecture, Beijing 100083, Peoples R China
[3] Chinese Acad Sci, Inst Microbiol, New Tech Ctr, Beijing 100101, Peoples R China
[4] Hyflux Filtech Shanghai Co Ltd, Shanghai 201700, Peoples R China
基金
美国国家科学基金会;
关键词
Ammonia; Direct contact membrane distillation; PVDF membranes; Mass transfer coefficient; Selectivity; REMOVAL; CONTACTORS; DENITRIFICATION; NITRIFICATION; PERVAPORATION; CHLORINATION; DESALINATION; WASTEWATERS; TOLUENE;
D O I
10.5004/dwt.2016.0131
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Three operation technologies based on PVDF membranes including membrane contactor (MC), direct contact membrane distillation with pure water as permeate solution (DCMD), reaction direct contact membrane distillation with sulfuric acid solution as permeate solution (RDCMD) were tested for ammonia removal from water. The effects of feed run parameters (temperature, pH, initial concentration and velocity) and permeate temperature on the ammonia removal rate, mass transfer coefficient and selectivity in RDCMD process were investigated in detail. Results showed that, comparing with MC and DCMD, RDCMD performed the highest ammonia removal efficiency and mass transfer coefficient. In RDCMD, feed pH value was proved to be the most dominant factor, when the pH value increased from 9 to 11, mass transfer coefficient increased noticeably from 0.54 x 10(-5) m s(-1) to 2.2 x 10(-5) m s(-1) and selectivity increased from 1.73 to 6.95, respectively, but with the further increase of pH from 11 to 13, mass transfer coefficient and selectivity increased slightly. Increasing feed temperature could lead to higher ammonia mass transfer coefficient but lower selectivity. Permeate-temperature was in favour of the selectivity, but had no remarkable effect on mass transfer coefficient. Feed velocity and initial concentration had a negligible influence on mass transfer coefficient and selectivity. A laboratory scale application of RDMCD was carried for 0.50 mol L-1 ammonia wastewater, after 4 h operation at optimal process conditions, 98.5% ammonia was removed, however, the membrane only was polluted a little and can be easily washed by deionized water. In addition, the PVDF membrane can maintain stable properties to resist 0.5 mol L-1 sulfuric acid solution, and is potential in the ammonia removal by RDCMD.
引用
收藏
页码:126 / 135
页数:10
相关论文
共 50 条
  • [31] Membrane distillation for sustainable wastewater treatment
    Shirazi, Mohammad Mahdi A. F.
    Dumee, Ludovic
    JOURNAL OF WATER PROCESS ENGINEERING, 2022, 47
  • [32] Thermal treatment enhanced the hydrophobicity of PVDF hollow fibers membrane for brine treatment using membrane distillation
    Gzara, Lassaad
    Softah, Ghassan
    Organji, Hussam
    Ahmed, Iqbal
    Alsaiari, Abdulmohsen O.
    Albeirutty, Mohammad
    Salam, Mohamed Abdel
    Bouguecha, Salah Al Tahar
    Macedonio, Francesca
    Drioli, Enrico
    SEPARATION AND PURIFICATION TECHNOLOGY, 2024, 334
  • [33] Applying Membrane Distillation for the Recovery of Nitrate from Saline Water Using PVDF Membranes Modified as Superhydrophobic Membranes
    Ebrahimi, Fatemeh
    Orooji, Yasin
    Razmjou, Amir
    POLYMERS, 2020, 12 (12) : 1 - 14
  • [34] Bicontinuous and cellular structure design of PVDF membranes by using binary solvents for the membrane distillation process
    Wang, Ziyi
    Tang, Yuanyuan
    Li, Baoan
    RSC ADVANCES, 2018, 8 (44): : 25159 - 25167
  • [35] Development of PVDF membranes for membrane distillation via vapour induced crystallisation
    AlMarzooqi, Faisal A.
    Bilad, M. R.
    Arafat, Hassan A.
    EUROPEAN POLYMER JOURNAL, 2016, 77 : 164 - 173
  • [36] The effect of chemistry of nanoparticle modifier groups on the PVDF membranes for membrane distillation
    Kumar, Rajesha
    Ahmed, Mansour
    Bhadrachari, Garudachari
    Al-Missri, Abbas
    Thomas, Jibu P.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2020, 164 : 1 - 10
  • [37] Development of PVDF membranes for membrane distillation via vapour induced crystallisation
    AlMarzooqi, Faisal A.
    Bilad, M.R.
    Arafat, Hassan A.
    European Polymer Journal, 2016, 77 : 164 - 173
  • [38] Beaded electrospun polyvinylidene fluoride (PVDF) membranes for membrane distillation (MD)
    Hu, Xuhui
    Chen, Xing
    Giagnorio, Mattia
    Wu, Chunhong
    Luo, Yunbai
    Helix-Nielsen, Claus
    Yu, Ping
    Zhang, Wenjing
    JOURNAL OF MEMBRANE SCIENCE, 2022, 661
  • [39] Beaded electrospun polyvinylidene fluoride (PVDF) membranes for membrane distillation (MD)
    Hu, Xuhui
    Chen, Xing
    Giagnorio, Mattia
    Wu, Chunhong
    Luo, Yunbai
    Hélix-Nielsen, Claus
    Yu, Ping
    Zhang, Wenjing
    Journal of Membrane Science, 2022, 661
  • [40] Fabrication of polymeric membranes for membrane distillation process and application for wastewater treatment: Critical review
    Tibi, Fida
    Charfi, Amine
    Cho, Jinwoo
    Kim, Jeonghwan
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2020, 141 : 190 - 201