Treatment of ammonia nitrogen wastewater by membrane distillation using PVDF membranes

被引:4
|
作者
Xia, Qiang [1 ]
Yun, Yanbin [1 ]
Chen, Jinjin [2 ]
Qu, Dan [1 ]
Li, Chunli [3 ]
Zhu, Shouwei [4 ]
机构
[1] Beijing Forestry Univ, Sch Environm Sci & Engn, Beijing 100083, Peoples R China
[2] Beijing Forestry Univ, Sch Landscape Architecture, Beijing 100083, Peoples R China
[3] Chinese Acad Sci, Inst Microbiol, New Tech Ctr, Beijing 100101, Peoples R China
[4] Hyflux Filtech Shanghai Co Ltd, Shanghai 201700, Peoples R China
基金
美国国家科学基金会;
关键词
Ammonia; Direct contact membrane distillation; PVDF membranes; Mass transfer coefficient; Selectivity; REMOVAL; CONTACTORS; DENITRIFICATION; NITRIFICATION; PERVAPORATION; CHLORINATION; DESALINATION; WASTEWATERS; TOLUENE;
D O I
10.5004/dwt.2016.0131
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Three operation technologies based on PVDF membranes including membrane contactor (MC), direct contact membrane distillation with pure water as permeate solution (DCMD), reaction direct contact membrane distillation with sulfuric acid solution as permeate solution (RDCMD) were tested for ammonia removal from water. The effects of feed run parameters (temperature, pH, initial concentration and velocity) and permeate temperature on the ammonia removal rate, mass transfer coefficient and selectivity in RDCMD process were investigated in detail. Results showed that, comparing with MC and DCMD, RDCMD performed the highest ammonia removal efficiency and mass transfer coefficient. In RDCMD, feed pH value was proved to be the most dominant factor, when the pH value increased from 9 to 11, mass transfer coefficient increased noticeably from 0.54 x 10(-5) m s(-1) to 2.2 x 10(-5) m s(-1) and selectivity increased from 1.73 to 6.95, respectively, but with the further increase of pH from 11 to 13, mass transfer coefficient and selectivity increased slightly. Increasing feed temperature could lead to higher ammonia mass transfer coefficient but lower selectivity. Permeate-temperature was in favour of the selectivity, but had no remarkable effect on mass transfer coefficient. Feed velocity and initial concentration had a negligible influence on mass transfer coefficient and selectivity. A laboratory scale application of RDMCD was carried for 0.50 mol L-1 ammonia wastewater, after 4 h operation at optimal process conditions, 98.5% ammonia was removed, however, the membrane only was polluted a little and can be easily washed by deionized water. In addition, the PVDF membrane can maintain stable properties to resist 0.5 mol L-1 sulfuric acid solution, and is potential in the ammonia removal by RDCMD.
引用
收藏
页码:126 / 135
页数:10
相关论文
共 50 条
  • [21] PVDF hollow fiber and nanofiber membranes for fresh water reclamation using membrane distillation
    Lijo Francis
    Noreddine Ghaffour
    Ahmad S. Alsaadi
    Suzana P. Nunes
    Gary L. Amy
    Journal of Materials Science, 2014, 49 : 2045 - 2053
  • [22] The potential of direct contact membrane distillation for industrial textile wastewater treatment using PVDF-Cloisite 15A nanocomposite membrane
    Molehtar, N. M.
    Lau, W. J.
    Ismail, A. F.
    Kartohardjono, S.
    Lai, S. O.
    Teoh, H. C.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2016, 111 : 284 - 293
  • [23] Dye wastewater treatment by direct contact membrane distillation using polyvinylidene fluoride hollow fiber membranes
    Mokhtar, Nadzirah M.
    Lau, Woei J.
    Ismail, Ahmad F.
    JOURNAL OF POLYMER ENGINEERING, 2015, 35 (05) : 471 - 479
  • [24] Review of ammonia recovery and removal from wastewater using hydrophobic membrane distillation and membrane contactor
    Zhu, Yingyuan
    Chang, Haiqing
    Yan, Zhongsen
    Liu, Caihong
    Liang, Ying
    Qu, Fangshu
    Liang, Heng
    Vidic, Radisav D.
    SEPARATION AND PURIFICATION TECHNOLOGY, 2024, 328
  • [25] Influence of solution and operating conditions on the treatment of aquaculture wastewater using direct contact membrane distillation: Ammonia rejection and membrane fouling
    Zhang, Bing
    Shen, Jing
    Xiong, Jianhui
    Shen, Yu
    Zhang, Bing
    Shi, Wenxin
    CHEMICAL ENGINEERING JOURNAL, 2023, 478 (478)
  • [26] Preparation of PVDF/TMKH-550 composite membrane and its adsorption performance for ammonia nitrogen wastewater
    Wang, Ziming
    Yuan, Jingjing
    Yang, Xin
    Feng, Xia
    Zhao, Yiping
    Chen, Li
    JOURNAL OF APPLIED POLYMER SCIENCE, 2023, 140 (37)
  • [27] Exergetic analysis of direct contact membrane distillation (DCMD) using PVDF hollow fiber membranes for the desalination brine treatment
    Zaheer, Abdul Hanan Muhammad
    Gzara, Lassaad
    Iqbal, Ahmed
    Macedonio, Fransesca
    Albeirutty, Mohammed
    Drioli, Enrico
    HELIYON, 2023, 9 (10)
  • [28] Treatment of radioactive wastewater using direct contact membrane distillation
    Liu, Haiyang
    Wang, Jianlong
    JOURNAL OF HAZARDOUS MATERIALS, 2013, 261 : 307 - 315
  • [29] Petrochemical wastewater treatment: Water recovery using membrane distillation
    Santos, Paula G.
    Scherer, Cintia M.
    Fisch, Adriano G.
    Rodrigues, Marco Antonio S.
    JOURNAL OF CLEANER PRODUCTION, 2020, 267 (267)
  • [30] Pharmaceutical wastewater treatment using direct contact membrane distillation
    Sim, Lee Nuang
    Jayaraman, Praveena
    Lau, Yi Hui
    Chong, Tzyy Haur
    Wang, Rong
    JOURNAL OF WATER PROCESS ENGINEERING, 2024, 68