Pixelated Columnar CsI:Tl Scintillator for High Resolution Radiography and Cone-Beam CT

被引:3
|
作者
Miller, Stuart R. [1 ]
Singh, Bipin [1 ]
Marshall, Matthew S. J. [1 ]
Brown, Conner [1 ]
Sheth, Niral [2 ]
Shi, Gengxin [2 ]
Siewerdsen, Jeffrey H. [2 ,3 ]
Zbijewski, Wojciech [2 ]
Nagarkar, Vivek V. [1 ]
机构
[1] Radiat Monitoring Devices Inc, Watertown, MA 02472 USA
[2] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[3] Johns Hopkins Univ, Russell H Morgan Dept Radiol, Baltimore, MD 21287 USA
关键词
microcolumnar scintillator; pixelated CsI scintillator; computed tomography; CBCT;
D O I
10.1117/12.2550196
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Microcolumnar CsI:Tl scintillator screens have been the gold standard in X-ray imaging for many years due to their high density, high atomic number, and scintillation efficiency. The structured screens provide an improvement in performance by channeling the light to the detector, improving detection efficiency and spatial resolution. We have taken this concept a step further by laser-machining the CsI:Tl scintillator to provide pixels that match the detector pixels. This allows for still thicker CsI:Tl layers up to 700 mu m pixelated with pitch of 100 mu m to match CMOS flat panel pixels, thus improving X-ray absorption and resolution. We are investigating the applications of CMOS detectors with pixelated scintillators for imaging of bone microarchitecture on diagnostic Cone Beam CT (CBCT) systems to provide improved quantitative metrics for diagnosis of osteoporosis and osteoarthritis. The scintillator design includes reflective coatings applied to the laser-cut grooves to improve optical isolation between pixels. Such coatings are created by atomic layer deposition (ALD), a unique approach, which permits formation of reflectors over inter-pixel grooves with aspect ratios as high as 140:1. Here we present initial results quantifying performance gains in CMOS detector resolution and their impact on the quality of bone microstructure segmentation. We demonstrate 77% gain in spatial resolution at 2 lp/mm and extension of the limiting resolution from 3 lp/mm to 4.5 lp/mm for the CMOS detector with a pixelated screen compared to a commercial sensor. In a bench-top CBCT study emulating diagnostic systems for orthopedic applications (extremity CBCT), we achieved >0.75 correlations in metrics of trabecular microarchitecture between pixelated CsI:Tl based CBCT and gold-standard micro-CT. The pixelated scintillator is expected to have significant impact for many other applications including mammography and digital radiography, where resolution and dose efficiency (DQE) of the detector are of critical importance.
引用
收藏
页数:7
相关论文
共 50 条
  • [41] Workflow and performance of intraoperative CT, cone-beam CT, and robotic cone-beam CT for spinal navigation in 503 consecutive patients
    Kendlbacher, Paul
    Tkatschenko, Dimitri
    Czabanka, Marcus
    Bayerl, Simon
    Bohner, Georg
    Woitzik, Johannes
    Vajkoczy, Peter
    Hecht, Nils
    NEUROSURGICAL FOCUS, 2022, 52 (01)
  • [42] A Method to Estimate Cone-Beam CT Dose Index and Cone-Beam Dose Length Product
    Kim, S.
    Song, H.
    Samei, E.
    Yin, F.
    Yoshizumi, T.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [43] Comparison of periapical radiography, panoramic, and cone-beam CT in the detection of dental caries in dog teeth
    Orhan, Kaan
    Ozemre, Mehmet Ozgur
    Secgin, Cansu Koseoglu
    Vural, Sevil Atalay
    Gur, Gurkan
    Kamburoglu, Kivanc
    ANKARA UNIVERSITESI VETERINER FAKULTESI DERGISI, 2019, 66 (04): : 379 - 384
  • [44] Wiener Filtering Using Object and Noise Power Spectra for CsI(Tl)-Scintillator Radiography Detectors
    Lee, Eunae
    Kim, Dong Sik
    2020 INTERNATIONAL CONFERENCE ON ELECTRONICS, INFORMATION, AND COMMUNICATION (ICEIC), 2020,
  • [45] On the Determination of the Beam Output of a Kilovoltage Cone-Beam CT
    Ding, G.
    Coffey, C.
    MEDICAL PHYSICS, 2010, 37 (06)
  • [46] A Hybrid Approach to Reduce Cone-Beam Artifacts for a Circular Orbit Cone-Beam CT System
    Choi, Shinkook
    Kim, Jinsung
    Baek, Jongduk
    IEEE ACCESS, 2018, 6 : 54595 - 54606
  • [47] CT Thermometry for Cone-beam CT Guided Ablation
    DeStefano, Zachary
    Abi-Jaoudeh, Nadine
    Li, Ming
    Wood, Bradford J.
    Summers, Ronald M.
    Yao, Jianhua
    MEDICAL IMAGING 2016: IMAGE-GUIDED PROCEDURES, ROBOTIC INTERVENTIONS, AND MODELING, 2016, 9786
  • [48] High-contrast object localization and removal in cone-beam CT
    Moseley, DJ
    Siewerdsen, JH
    Jaffray, DA
    MEDICAL IMAGING 2005: PHYSICS OF MEDICAL IMAGING, PTS 1 AND 2, 2005, 5745 : 40 - 50
  • [49] Early clinical experience on cone-beam CT
    Yumi Makimoto
    Kenji Matsuzaki
    Shusaku Yoshida
    Hiromu Nishitani
    Journal of Digital Imaging, 1998, 11 : 211 - 213
  • [50] Measurements for quality assurance in the cone-beam CT
    Walter, C.
    Wertz, H.
    Steil, V.
    Lohr, F.
    Wenz, F.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2006, 182 : 95 - 96