Pixelated Columnar CsI:Tl Scintillator for High Resolution Radiography and Cone-Beam CT

被引:3
|
作者
Miller, Stuart R. [1 ]
Singh, Bipin [1 ]
Marshall, Matthew S. J. [1 ]
Brown, Conner [1 ]
Sheth, Niral [2 ]
Shi, Gengxin [2 ]
Siewerdsen, Jeffrey H. [2 ,3 ]
Zbijewski, Wojciech [2 ]
Nagarkar, Vivek V. [1 ]
机构
[1] Radiat Monitoring Devices Inc, Watertown, MA 02472 USA
[2] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[3] Johns Hopkins Univ, Russell H Morgan Dept Radiol, Baltimore, MD 21287 USA
关键词
microcolumnar scintillator; pixelated CsI scintillator; computed tomography; CBCT;
D O I
10.1117/12.2550196
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Microcolumnar CsI:Tl scintillator screens have been the gold standard in X-ray imaging for many years due to their high density, high atomic number, and scintillation efficiency. The structured screens provide an improvement in performance by channeling the light to the detector, improving detection efficiency and spatial resolution. We have taken this concept a step further by laser-machining the CsI:Tl scintillator to provide pixels that match the detector pixels. This allows for still thicker CsI:Tl layers up to 700 mu m pixelated with pitch of 100 mu m to match CMOS flat panel pixels, thus improving X-ray absorption and resolution. We are investigating the applications of CMOS detectors with pixelated scintillators for imaging of bone microarchitecture on diagnostic Cone Beam CT (CBCT) systems to provide improved quantitative metrics for diagnosis of osteoporosis and osteoarthritis. The scintillator design includes reflective coatings applied to the laser-cut grooves to improve optical isolation between pixels. Such coatings are created by atomic layer deposition (ALD), a unique approach, which permits formation of reflectors over inter-pixel grooves with aspect ratios as high as 140:1. Here we present initial results quantifying performance gains in CMOS detector resolution and their impact on the quality of bone microstructure segmentation. We demonstrate 77% gain in spatial resolution at 2 lp/mm and extension of the limiting resolution from 3 lp/mm to 4.5 lp/mm for the CMOS detector with a pixelated screen compared to a commercial sensor. In a bench-top CBCT study emulating diagnostic systems for orthopedic applications (extremity CBCT), we achieved >0.75 correlations in metrics of trabecular microarchitecture between pixelated CsI:Tl based CBCT and gold-standard micro-CT. The pixelated scintillator is expected to have significant impact for many other applications including mammography and digital radiography, where resolution and dose efficiency (DQE) of the detector are of critical importance.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Evaluation of the spatial resolution characteristics of a cone-beam breast CT scanner
    Kwan, Alexander L. C.
    Boone, John M.
    Yang, Kai
    Huang, Shih-Ying
    [J]. MEDICAL PHYSICS, 2007, 34 (01) : 275 - 281
  • [22] Root-contact evaluation by panoramic radiography and cone-beam computed tomography of super-high resolution
    Leuzinger, Michael
    Dudic, Alexander
    Giannopoulou, Catherine
    Kiliaridis, Stavros
    [J]. AMERICAN JOURNAL OF ORTHODONTICS AND DENTOFACIAL ORTHOPEDICS, 2010, 137 (03) : 389 - 392
  • [23] Detection of simulated periodontal defects using cone-beam CT and digital intraoral radiography
    Bayat, Samaneh
    Talaeipour, Ahmad Reza
    Sarlati, Fatemeh
    [J]. DENTOMAXILLOFACIAL RADIOLOGY, 2016, 45 (06)
  • [24] Direct comparison of conventional radiography and cone-beam CT in small bone and joint trauma
    De Smet, E.
    De Praeter, G.
    Verstraete, K. L. A.
    Wouters, K.
    De Beuckeleer, Luc
    Vanhoenacker, F. M. H. M.
    [J]. SKELETAL RADIOLOGY, 2015, 44 (08) : 1111 - 1117
  • [25] Beam hardening correction for a cone-beam CT system and its effect on spatial resolution
    赵维
    付国涛
    孙翠丽
    王燕芳
    魏存峰
    曹大泉
    阙介民
    唐晓
    史戒坚
    魏龙
    郁忠强
    [J]. Chinese Physics C, 2011, (10) : 978 - 985
  • [26] Direct comparison of conventional radiography and cone-beam CT in small bone and joint trauma
    E. De Smet
    G. De Praeter
    K. L. A. Verstraete
    K. Wouters
    Luc De Beuckeleer
    F. M. H. M. Vanhoenacker
    [J]. Skeletal Radiology, 2015, 44 : 1111 - 1117
  • [27] Beam hardening correction for a cone-beam CT system and its effect on spatial resolution
    Zhao Wei
    Fu Guo-Tao
    Sun Cui-Li
    Wang Yan-Fang
    Wei Cun-Feng
    Cao Da-Quan
    Que Jie-Min
    Tang Xiao
    Shi Rong-Jian
    Wei Long
    Yu Zhong-Qiang
    [J]. CHINESE PHYSICS C, 2011, 35 (10) : 978 - 985
  • [28] Crescent artifacts in cone-beam CT
    Giles, William
    Bowsher, James
    Li, Hao
    Yin, Fang-Fang
    [J]. MEDICAL PHYSICS, 2011, 38 (04) : 2116 - 2121
  • [29] Clinical implementation of a cone-beam CT
    Betgen, A
    van Herk, M
    Remeijer, P
    Sonke, JJ
    [J]. RADIOTHERAPY AND ONCOLOGY, 2004, 73 : S158 - S158
  • [30] Breathing motion in cone-beam CT
    Rit, S.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2019, 133 : S119 - S120