Pixelated Columnar CsI:Tl Scintillator for High Resolution Radiography and Cone-Beam CT

被引:3
|
作者
Miller, Stuart R. [1 ]
Singh, Bipin [1 ]
Marshall, Matthew S. J. [1 ]
Brown, Conner [1 ]
Sheth, Niral [2 ]
Shi, Gengxin [2 ]
Siewerdsen, Jeffrey H. [2 ,3 ]
Zbijewski, Wojciech [2 ]
Nagarkar, Vivek V. [1 ]
机构
[1] Radiat Monitoring Devices Inc, Watertown, MA 02472 USA
[2] Johns Hopkins Univ, Dept Biomed Engn, Baltimore, MD 21205 USA
[3] Johns Hopkins Univ, Russell H Morgan Dept Radiol, Baltimore, MD 21287 USA
关键词
microcolumnar scintillator; pixelated CsI scintillator; computed tomography; CBCT;
D O I
10.1117/12.2550196
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Microcolumnar CsI:Tl scintillator screens have been the gold standard in X-ray imaging for many years due to their high density, high atomic number, and scintillation efficiency. The structured screens provide an improvement in performance by channeling the light to the detector, improving detection efficiency and spatial resolution. We have taken this concept a step further by laser-machining the CsI:Tl scintillator to provide pixels that match the detector pixels. This allows for still thicker CsI:Tl layers up to 700 mu m pixelated with pitch of 100 mu m to match CMOS flat panel pixels, thus improving X-ray absorption and resolution. We are investigating the applications of CMOS detectors with pixelated scintillators for imaging of bone microarchitecture on diagnostic Cone Beam CT (CBCT) systems to provide improved quantitative metrics for diagnosis of osteoporosis and osteoarthritis. The scintillator design includes reflective coatings applied to the laser-cut grooves to improve optical isolation between pixels. Such coatings are created by atomic layer deposition (ALD), a unique approach, which permits formation of reflectors over inter-pixel grooves with aspect ratios as high as 140:1. Here we present initial results quantifying performance gains in CMOS detector resolution and their impact on the quality of bone microstructure segmentation. We demonstrate 77% gain in spatial resolution at 2 lp/mm and extension of the limiting resolution from 3 lp/mm to 4.5 lp/mm for the CMOS detector with a pixelated screen compared to a commercial sensor. In a bench-top CBCT study emulating diagnostic systems for orthopedic applications (extremity CBCT), we achieved >0.75 correlations in metrics of trabecular microarchitecture between pixelated CsI:Tl based CBCT and gold-standard micro-CT. The pixelated scintillator is expected to have significant impact for many other applications including mammography and digital radiography, where resolution and dose efficiency (DQE) of the detector are of critical importance.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] A study on spatial resolution of pixelated CsI(Tl) scintillator
    Kim, Byoung-Jik
    Cha, Bo Kyung
    Jeon, Hosang
    Chi, Yong Ki
    Cho, Gyuseong
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 579 (01): : 205 - 207
  • [2] Improvement of the sensitivity and spatial resolution of pixelated CsI:Tl scintillator with reflective coating
    Cha, Bo Kyung
    Bae, Jun Hyung
    Lee, Chae-hun
    Jeon, Hosang
    Kim, Hyunduk
    Chang, Sungho
    Kang, Bo-Sun
    Cho, Gyuseong
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2009, 607 (01): : 145 - 149
  • [3] A New Columnar CsI(Tl) Scintillator for iQID detectors
    Han, Ling
    Miller, Brian W.
    Barber, H. Bradford
    Nagarkar, Vivek V.
    Furenlid, Lars R.
    [J]. MEDICAL APPLICATIONS OF RADIATION DETECTORS IV, 2014, 9214
  • [4] High-resolution extremity cone-beam CT with a CMOS detector: Task-based optimization of scintillator thickness
    Cao, Q.
    Brehler, M.
    Sisniega, A.
    Stayman, J. W.
    Yorkston, J.
    Siewerdsen, J. H.
    Zbijewski, W.
    [J]. MEDICAL IMAGING 2017: PHYSICS OF MEDICAL IMAGING, 2017, 10132
  • [5] LiF/CsI:Tl Scintillator for High-Resolution Neutron Imaging
    Miller, Stuart R.
    Marshall, Matthew S. J.
    Wart, Megan
    Bilheux, Hassina Z.
    Santodonato, Louis J.
    Riedel, Rick
    Nagarkar, Vivek V.
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2019, 66 (10) : 2261 - 2264
  • [6] High-Resolution Extremity Cone-Beam CT Prototype System
    Bernstein, M.
    Karp, J.
    Li, K.
    Zbijewski, W.
    [J]. MEDICAL PHYSICS, 2018, 45 (06) : E539 - E539
  • [7] Spatial resolution of iterative cone-beam CT reconstruction
    Nielsen, T
    Köhler, T
    Proksa, R
    van Stevendaal, U
    [J]. 2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3253 - 3256
  • [8] High-resolution FPD cone-beam CT for dental and orthopedic surgery
    Baba, R
    Ueda, K
    Kadomura, T
    [J]. RADIOLOGY, 2002, 225 : 194 - 194
  • [9] Multiresolution iterative reconstruction in high-resolution extremity cone-beam CT
    Cao, Qian
    Zbijewski, Wojciech
    Sisniega, Alejandro
    Yorkston, John
    Siewerdsen, Jeffrey H.
    Stayman, J. Webster
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (20): : 7263 - 7281
  • [10] Evaluation of Ultra-High-Resolution Cone-Beam CT Prototype of Twin Robotic Radiography System for Cadaveric Wrist Imaging
    Grunz, Jan-Peter
    Weng, Andreas Max
    Gietzen, Carsten Herbert
    Veyhl-Wichmann, Maike
    Pennig, Lenhard
    Kunz, Andreas
    Schmitt, Rainer
    Erguen, Sueleyman
    Bley, Thorsten Alexander
    Gassenmaier, Tobias
    [J]. ACADEMIC RADIOLOGY, 2021, 28 (10) : E314 - E322