Treatment of Wastewater from a Food and Beverage Industry Using Conventional Wastewater Treatment Integrated with Membrane Bioreactor System: A Pilot-Scale Case Study

被引:13
|
作者
Ng, Sabrina Ng Muhamad [1 ,2 ]
Idrus, Syazwani [1 ]
Ahsan, Amimul [3 ,4 ]
Marzuki, Tuan Nurfarhana Tuan Mohd [1 ]
Mahat, Siti Baizura [5 ]
机构
[1] Univ Putra Malaysia, Fac Engn, Dept Civil Engn, Serdang 43400, Malaysia
[2] Wisma Albe Adv, Cheme Adv Serv Sdn Bhd, 2,Jalan BS7-16, Seri Kembangan 43300, Malaysia
[3] Islamic Univ Technol IUT, Dept Civil & Environm Engn, Gazipur 1704, Bangladesh
[4] Swinburne Univ Technol, Dept Civil & Construct Engn, Melbourne, Vic 3122, Australia
[5] Univ Putra Malaysia, Fac Engn, Dept Chem & Environm Engn, Serdang 43400, Malaysia
关键词
food and beverage wastewater; wastewater treatment plant; membrane bioreactor; hollow fiber; flat sheet; mixed liquor suspended solid and dissolved air floatation; FLAT-SHEET MEMBRANES; HOLLOW-FIBER; MBR TECHNOLOGY; FOULING INDEX; PERFORMANCE; OPERATION; FLUX; TEMPERATURE;
D O I
10.3390/membranes11060456
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This study compares the performance of the Hollow Fiber (HF) and Flat Sheet (FS) types of membrane bioreactors (MBRs) for the treatment of food and beverage (F&B) industry wastewater in a pilot-scale study of a wastewater treatment plant (WWTP). HF and FS membrane configurations were evaluated at two different Mixed Liquor Suspended Solid (MLSS) levels: 6000 mg/L and 12,000 mg/L. The performance of each configuration was evaluated in terms of Chemical Oxygen Demand (COD) and Total Suspended Solid (TSS) removals for effluent quality measurement. The transmembrane pressure (TMP), flux rate, and silt density index (SDI) were monitored and calculated for membrane fouling assessment. The results show that the rejection rates of COD and TSS for HF and FS membrane types were more than 84% for the two different MLSS levels. During the study, the HF membrane recorded 0.3 bar transmembrane pressure, which complies with the recommended range (i.e., two to three times of chemical cleaning). On the other hand, the FS membrane operates without chemical cleaning, and the TMP value was below the recommended range at 0.2 bar. It was found that the flux values recorded for both the HF and FS systems were within the recommended range of 40 L/m(2)/h. Analysis of SDI revealed that the calculated index ranged between 1 and 2.38 and was within the allowable limit of 3. Both types of MBR consistently achieved an 80% to 95% rejection rate of COD and TSS. Effluent quality measurement of treated F&B wastewater in this pilot-scale study using a WWTP integrated with an MBR indicated a good achievement with compliance with the Malaysia industrial effluent discharge standards.
引用
收藏
页数:17
相关论文
共 50 条
  • [41] A pilot-scale hybrid upflow anaerobic sludge blanket reactor (UASB)-membrane bioreactor (MBR) system for berberine wastewater treatment
    Cui, Xiaoyu
    He, Xuwen
    Zeng, Ping
    Qiu, Guanglei
    Song, Yonghui
    Research of Environmental Sciences, 2015, 28 (08) : 1295 - 1301
  • [42] Large pilot-scale submerged anaerobic membrane bioreactor for the treatment of municipal wastewater and biogas production at 25 ° C
    Kong, Zhe
    Wu, Jiang
    Rong, Chao
    Wang, Tianjie
    Li, Lu
    Luo, Zibin
    Ji, Jiayuan
    Hanaoka, Taira
    Sakemi, Shinichi
    Ito, Masami
    Kobayashi, Shigeki
    Kobayashi, Masumi
    Qin, Yu
    Li, Yu-You
    BIORESOURCE TECHNOLOGY, 2021, 319 (319)
  • [43] Treatment of oil refining industry wastewater with membrane-bioreactor system
    Zhang, PY
    Zeng, GM
    Zhang, GM
    Hu, JY
    Future of Urban Wastewater Systems - Decentralisation and Reuse, 2005, : 595 - 601
  • [44] Pilot Tests on the Treatment of Bath Wastewater by a Membrane Bioreactor
    Shi, Yan
    Zhong, Songtao
    Li, Zhaohui
    MEMBRANES, 2021, 11 (02) : 1 - 11
  • [45] Fate of sex hormones in two pilot-scale municipal wastewater treatment plants: Conventional treatment
    Esperanza, Mar
    Suidan, Makram T.
    Marfil-Vega, Ruth
    Gonzalez, Cristina
    Sorial, George A.
    McCauley, Paul
    Brenner, Richard
    CHEMOSPHERE, 2007, 66 (08) : 1535 - 1544
  • [46] Excellent performance of anaerobic membrane bioreactor in treatment of distillery wastewater at pilot scale
    Deschamps, Laure
    Merlet, David
    Lemaire, Julien
    Imatoukene, Nabila
    Filali, Rayen
    Clement, Tiphaine
    Lopez, Michel
    Theoleyre, Marc-Andre
    JOURNAL OF WATER PROCESS ENGINEERING, 2021, 41
  • [47] Conceptual design optimization of an integrated membrane bioreactor system for wastewater treatment
    Ko, Daeho
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2018, 132 : 385 - 398
  • [48] Pilot study on municipal wastewater treatment by a modified submerged membrane bioreactor
    Wei, CH
    Huang, X
    Wen, XH
    FUTURE OF URBAN WASTEWATER SYSTEMS - DECENTRALISATION AND REUSE, 2005, : 509 - 517
  • [49] Treatment and Reuse of Wastewater from Beverage Industry
    Haroon, Hajira
    Waseem, Amir
    Mahmood, Qaisar
    JOURNAL OF THE CHEMICAL SOCIETY OF PAKISTAN, 2013, 35 (01): : 5 - 10
  • [50] Pilot study on municipal wastewater treatment by a modified submerged membrane bioreactor
    Wei, Chunhai
    Huang, Xia
    Wen, Xianghua
    WATER SCIENCE AND TECHNOLOGY, 2006, 53 (09) : 103 - 110