Treatment of Wastewater from a Food and Beverage Industry Using Conventional Wastewater Treatment Integrated with Membrane Bioreactor System: A Pilot-Scale Case Study

被引:13
|
作者
Ng, Sabrina Ng Muhamad [1 ,2 ]
Idrus, Syazwani [1 ]
Ahsan, Amimul [3 ,4 ]
Marzuki, Tuan Nurfarhana Tuan Mohd [1 ]
Mahat, Siti Baizura [5 ]
机构
[1] Univ Putra Malaysia, Fac Engn, Dept Civil Engn, Serdang 43400, Malaysia
[2] Wisma Albe Adv, Cheme Adv Serv Sdn Bhd, 2,Jalan BS7-16, Seri Kembangan 43300, Malaysia
[3] Islamic Univ Technol IUT, Dept Civil & Environm Engn, Gazipur 1704, Bangladesh
[4] Swinburne Univ Technol, Dept Civil & Construct Engn, Melbourne, Vic 3122, Australia
[5] Univ Putra Malaysia, Fac Engn, Dept Chem & Environm Engn, Serdang 43400, Malaysia
关键词
food and beverage wastewater; wastewater treatment plant; membrane bioreactor; hollow fiber; flat sheet; mixed liquor suspended solid and dissolved air floatation; FLAT-SHEET MEMBRANES; HOLLOW-FIBER; MBR TECHNOLOGY; FOULING INDEX; PERFORMANCE; OPERATION; FLUX; TEMPERATURE;
D O I
10.3390/membranes11060456
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
This study compares the performance of the Hollow Fiber (HF) and Flat Sheet (FS) types of membrane bioreactors (MBRs) for the treatment of food and beverage (F&B) industry wastewater in a pilot-scale study of a wastewater treatment plant (WWTP). HF and FS membrane configurations were evaluated at two different Mixed Liquor Suspended Solid (MLSS) levels: 6000 mg/L and 12,000 mg/L. The performance of each configuration was evaluated in terms of Chemical Oxygen Demand (COD) and Total Suspended Solid (TSS) removals for effluent quality measurement. The transmembrane pressure (TMP), flux rate, and silt density index (SDI) were monitored and calculated for membrane fouling assessment. The results show that the rejection rates of COD and TSS for HF and FS membrane types were more than 84% for the two different MLSS levels. During the study, the HF membrane recorded 0.3 bar transmembrane pressure, which complies with the recommended range (i.e., two to three times of chemical cleaning). On the other hand, the FS membrane operates without chemical cleaning, and the TMP value was below the recommended range at 0.2 bar. It was found that the flux values recorded for both the HF and FS systems were within the recommended range of 40 L/m(2)/h. Analysis of SDI revealed that the calculated index ranged between 1 and 2.38 and was within the allowable limit of 3. Both types of MBR consistently achieved an 80% to 95% rejection rate of COD and TSS. Effluent quality measurement of treated F&B wastewater in this pilot-scale study using a WWTP integrated with an MBR indicated a good achievement with compliance with the Malaysia industrial effluent discharge standards.
引用
收藏
页数:17
相关论文
共 50 条
  • [21] Treatment of dying wastewater from a woolen mill with a pilot-scale anaerobic/oxic membrane bioreactor (A/O MBR)
    Zheng, X.
    Zhu, X.
    Fan, Y.
    Huanjing Kexue/Environmental Science, 2001, 22 (04): : 91 - 94
  • [22] Comparison of pilot scale performances between membrane bioreactor and hybrid conventional wastewater treatment systems
    Yoon, TI
    Lee, HS
    Kim, CG
    JOURNAL OF MEMBRANE SCIENCE, 2004, 242 (1-2) : 5 - 12
  • [23] Pilot-scale study of biomass reduction in wastewater treatment
    Wang, Qunhui
    Ai, Hengyu
    Li, Xuesong
    Liu, Haitao
    Xie, Weimin
    WATER ENVIRONMENT RESEARCH, 2007, 79 (05) : 521 - 527
  • [24] Petrochemical wastewater treatment with a pilot-scale bioaugmented biological treatment system
    Zhao Li-jun
    Ma Fang
    Guo Jing-bo
    Zhao Qing-liang
    JOURNAL OF ZHEJIANG UNIVERSITY-SCIENCE A, 2007, 8 (11): : 1831 - 1838
  • [25] Mixed pharmaceutical wastewater treatment by integrated membrane-aerated biofilm reactor (MABR) system - A pilot-scale study
    Wei, Xin
    Li, Baoan
    Zhao, Song
    Wang, Li
    Zhang, Hongyu
    Li, Chang
    Wang, Shichang
    BIORESOURCE TECHNOLOGY, 2012, 122 : 189 - 195
  • [26] Petrochemical wastewater treatment with a pilot-scale bioaugmented biological treatment system
    Li-jun Zhao
    Fang Ma
    Jing-bo Guo
    Qing-liang Zhao
    Journal of Zhejiang University-SCIENCE A, 2007, 8 : 1831 - 1838
  • [28] A pilot study on a submerged membrane bioreactor for domestic wastewater treatment
    Liu, R.
    Huang, X.
    Chen, L.
    Wang, C.
    Qian, Y.
    1761, Marcel Dekker Inc, New York (35):
  • [29] A pilot study on a submerged membrane bioreactor for domestic wastewater treatment
    Liu, R
    Huang, X
    Chen, LJ
    Wang, CW
    Qian, Y
    JOURNAL OF ENVIRONMENTAL SCIENCE AND HEALTH PART A-TOXIC/HAZARDOUS SUBSTANCES & ENVIRONMENTAL ENGINEERING, 2000, 35 (10): : 1761 - 1772
  • [30] Advanced wastewater treatment using membrane bioreactor system
    Bhaduri, Soumyadeep
    Mazumder, Debabrata
    JOURNAL OF THE INDIAN CHEMICAL SOCIETY, 2020, 97 (12A) : 2643 - 2655