Laser reflectance imaging of human forearms and their tissue-equivalent phantoms

被引:14
|
作者
Anand, NS [1 ]
Kumar, D [1 ]
Srinivasan, R [1 ]
Singh, M [1 ]
机构
[1] Indian Inst Technol, Biomed Engn Div, Madras, Tamil Nadu, India
关键词
laser reflectance; human forearm; paraffin wax; tissue-equivalent phantoms;
D O I
10.1007/BF02343535
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Laser back-scattered radiation from a human forearm is affected by the compositional variation in tissues and was imaged by a reflectance imaging system. The measurement probe consisted of one input fibre and one output fibre, separated by a distance of 0.3cm. The diffuse reflectance data were collected by placing the probe on the forearm. By interpolation and median filtering of these data, the colour-coded reflectance images of the forearms of ten subjects were reconstructed. For comparative analysis of the mean reflectance, the forearm area was divided into ten regions. The mean normalised back-scattered intensity (NBI) near the ulnar region of the wrist was 4.76 +/- 0.24% and was significantly higher (p<0.0005) compared with that at other regions, which varied from 3.49 +/- 0.17% to 4.43 +/- 0.14%. Tissue-equivalent phantoms of these, required for the clinical assessment of optical techniques, were constructed using various combinations of paraffin wax and dyes. The matching of the NBI images of these stable and inexpensive phantoms with those of the forearms of the respective subjects showed the similarity of their optical parameters.
引用
收藏
页码:28 / 32
页数:5
相关论文
共 50 条
  • [41] ENDOTHERMIC PROCESSES IN TISSUE-EQUIVALENT PLASTIC
    FLEMING, DM
    GLASS, WA
    RADIATION RESEARCH, 1969, 37 (02) : 316 - &
  • [42] TISSUE-EQUIVALENT MATERIALS AND THE ICRU SPHERE
    HARDER, D
    HERMANN, KP
    RADIATION PROTECTION DOSIMETRY, 1985, 12 (02) : 125 - 128
  • [43] NEW ULTRASOUND TISSUE-EQUIVALENT MATERIAL
    BURLEW, MM
    MADSEN, EL
    ZAGZEBSKI, JA
    BANJAVIC, RA
    SUM, SW
    RADIOLOGY, 1980, 134 (02) : 517 - 520
  • [44] Advancements in Tissue-Equivalent Gel Dosimeters
    Sagsoz, Mustafa Erdem
    Korkut, Ozlem
    Gallo, Salvatore
    GELS, 2025, 11 (02)
  • [45] DEVELOPMENT OF A TISSUE-EQUIVALENT PHANTOM FOR DIAPHANOGRAPHY
    LINFORD, J
    SHALEV, S
    BEWS, J
    BROWN, R
    SCHIPPER, H
    MEDICAL PHYSICS, 1986, 13 (06) : 869 - 875
  • [46] A TISSUE-EQUIVALENT UPPER ABDOMINAL PHANTOM
    SCHERZINGER, AL
    CARSON, PL
    CLAYMAN, W
    CARTER, W
    JOHNSON, ML
    RASHBAUM, C
    JOURNAL OF ULTRASOUND IN MEDICINE, 1983, 2 (10) : 455 - 462
  • [47] Phantoms as a tissue-equivalent Testing Environment for active Medical Implants for the Examination of Malfunctions and radiation-induced Losses
    Stich, M.
    Bluemlein, L.
    Schmidl, F.
    Moser, S.
    Loesch, R.
    Hipp, M.
    Koestler, H.
    Kressmann, M.
    Kreutner, J.
    Schaefers, G.
    Ringler, R.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2017, 193 : S106 - S106
  • [48] DOSIMETRY IN TISSUE-EQUIVALENT PHANTOMS EXPOSED TO HIGH-ENERGY ELECTRONS - CAVITY THEORY TO MONTE-CARLO
    OBRIEN, K
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1977, 26 : 501 - 502
  • [49] Characterising breast tissue for the development of a tissue-equivalent phantom
    MJ Farquharson
    Breast Cancer Research, 2 (Suppl 2)
  • [50] Compact Tissue-equivalent Proportional Counter for Deep Space Human Missions
    Straume, T.
    Braby, L. A.
    Borak, T. B.
    Lusby, T.
    Warner, D. W.
    Perez-Nunez, D.
    HEALTH PHYSICS, 2015, 109 (04): : 277 - 283