Laser reflectance imaging of human forearms and their tissue-equivalent phantoms

被引:14
|
作者
Anand, NS [1 ]
Kumar, D [1 ]
Srinivasan, R [1 ]
Singh, M [1 ]
机构
[1] Indian Inst Technol, Biomed Engn Div, Madras, Tamil Nadu, India
关键词
laser reflectance; human forearm; paraffin wax; tissue-equivalent phantoms;
D O I
10.1007/BF02343535
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Laser back-scattered radiation from a human forearm is affected by the compositional variation in tissues and was imaged by a reflectance imaging system. The measurement probe consisted of one input fibre and one output fibre, separated by a distance of 0.3cm. The diffuse reflectance data were collected by placing the probe on the forearm. By interpolation and median filtering of these data, the colour-coded reflectance images of the forearms of ten subjects were reconstructed. For comparative analysis of the mean reflectance, the forearm area was divided into ten regions. The mean normalised back-scattered intensity (NBI) near the ulnar region of the wrist was 4.76 +/- 0.24% and was significantly higher (p<0.0005) compared with that at other regions, which varied from 3.49 +/- 0.17% to 4.43 +/- 0.14%. Tissue-equivalent phantoms of these, required for the clinical assessment of optical techniques, were constructed using various combinations of paraffin wax and dyes. The matching of the NBI images of these stable and inexpensive phantoms with those of the forearms of the respective subjects showed the similarity of their optical parameters.
引用
收藏
页码:28 / 32
页数:5
相关论文
共 50 条
  • [31] THERMOGRAPHIC INVESTIGATION OF ULTRASONICALLY INDUCED TEMPERATURE DISTRIBUTION IN TISSUES AND TISSUE-EQUIVALENT PHANTOMS.
    Pashovkin, T.
    Khiznyak, E.
    Sarvazyan, A.
    Archives of Acoustics, 1983, 9 (1-2) : 15 - 21
  • [32] NEUTRON PERSONNEL DOSIMETRY ON TISSUE-EQUIVALENT PHANTOMS BY SOLID-STATE TRACK DETECTORS
    DORSCHEL, B
    STOLZ, W
    KERNENERGIE, 1970, 13 (09): : 290 - &
  • [33] Three-Dimensional Printing for Construction of Tissue-Equivalent Anthropomorphic Phantoms and Determination of Conceptus Dose
    Hoerner, Matthew R.
    Maynard, Matthew R.
    Rajon, Didier A.
    Bova, Frank J.
    Hintenlang, David E.
    AMERICAN JOURNAL OF ROENTGENOLOGY, 2018, 211 (06) : 1283 - 1290
  • [35] TIME-RESOLVED OPTICAL IMAGING OF A SOLID TISSUE-EQUIVALENT PHANTOM
    HEBDEN, JC
    HALL, DJ
    FIRBANK, M
    DELPY, DT
    APPLIED OPTICS, 1995, 34 (34) : 8038 - 8047
  • [36] An Experimental Study on the Effect of Fat Conductivity on Voltage Distribution and Muscle Recruitment Using Tissue-Equivalent Phantoms
    Fukuhara, Yuto
    Gomez-Tames, Jose
    Yu, Wenwei
    2013 E-HEALTH AND BIOENGINEERING CONFERENCE (EHB), 2013,
  • [37] Tissue-Equivalent Phantoms in the 60-GHz Band and Their Application to the Body-Centric Propagation Studies
    Zhadobov, Maxim
    Guraliuc, Anda
    Chahat, Nacer
    Sauleau, Ronan
    2014 IEEE MTT-S INTERNATIONAL MICROWAVE WORKSHOP SERIES ON RF AND WIRELESS TECHNOLOGIES FOR BIOMEDICAL AND HEALTHCARE APPLICATIONS (IMWS-BIO), 2014,
  • [38] DEVELOPMENT OF A TISSUE-EQUIVALENT PHANTOM FOR DIAPHANOGRAPHY
    LINFORD, J
    SHALEV, S
    BEWS, J
    BROWN, R
    SCHIPPER, H
    MEDICAL PHYSICS, 1986, 13 (04) : 574 - 574
  • [39] Design of tissue-equivalent proportional counters
    Kliauga, P
    Waker, AJ
    Barthe, J
    RADIATION PROTECTION DOSIMETRY, 1995, 61 (04) : 309 - 322