Laser reflectance imaging of human forearms and their tissue-equivalent phantoms

被引:14
|
作者
Anand, NS [1 ]
Kumar, D [1 ]
Srinivasan, R [1 ]
Singh, M [1 ]
机构
[1] Indian Inst Technol, Biomed Engn Div, Madras, Tamil Nadu, India
关键词
laser reflectance; human forearm; paraffin wax; tissue-equivalent phantoms;
D O I
10.1007/BF02343535
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Laser back-scattered radiation from a human forearm is affected by the compositional variation in tissues and was imaged by a reflectance imaging system. The measurement probe consisted of one input fibre and one output fibre, separated by a distance of 0.3cm. The diffuse reflectance data were collected by placing the probe on the forearm. By interpolation and median filtering of these data, the colour-coded reflectance images of the forearms of ten subjects were reconstructed. For comparative analysis of the mean reflectance, the forearm area was divided into ten regions. The mean normalised back-scattered intensity (NBI) near the ulnar region of the wrist was 4.76 +/- 0.24% and was significantly higher (p<0.0005) compared with that at other regions, which varied from 3.49 +/- 0.17% to 4.43 +/- 0.14%. Tissue-equivalent phantoms of these, required for the clinical assessment of optical techniques, were constructed using various combinations of paraffin wax and dyes. The matching of the NBI images of these stable and inexpensive phantoms with those of the forearms of the respective subjects showed the similarity of their optical parameters.
引用
收藏
页码:28 / 32
页数:5
相关论文
共 50 条
  • [1] Laser reflectance imaging of human forearms and their tissue-equivalent phantoms
    N. S. Anand
    D. Kumar
    R. Srinivasan
    M. Singh
    Medical and Biological Engineering and Computing, 2003, 41 : 28 - 32
  • [2] Laser reflectance imaging of curved tissue-equivalent phantoms
    Kumar, T. Arun
    Singh, Megha
    Kumaravel, M.
    2005 27TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOLS 1-7, 2005, : 1468 - 1471
  • [3] TISSUE-EQUIVALENT PHANTOMS FOR ULTRASONIC-IMAGING
    ZAGZEBSKI, JA
    MADSEN, EL
    BANJAVIC, RA
    JACOBSON, DJ
    PHYSICS IN MEDICINE AND BIOLOGY, 1980, 25 (04): : 788 - 789
  • [4] TISSUE-EQUIVALENT MATERIALS FOR HUMAN PHANTOMS AND DOSIMETRY
    FRIGERIO, NA
    LAVOY, LL
    STOWE, RS
    RADIATION RESEARCH, 1976, 67 (03) : 615 - 615
  • [5] Development of biological tissue-equivalent phantoms for optical imaging
    Srinivasan, R.
    Singh, Megha
    Indian Journal of Experimental Biology, 2002, 40 (05) : 531 - 535
  • [6] PHANTOMS AND TISSUE-EQUIVALENT MATERIALS
    JONES, DEA
    BRITISH JOURNAL OF RADIOLOGY, 1970, 43 (505): : 76 - &
  • [7] Tissue-equivalent phantoms for high frequencies
    Beck, BL
    Jenkins, KA
    Rocca, JR
    Fitzsimmons, JR
    CONCEPTS IN MAGNETIC RESONANCE PART B-MAGNETIC RESONANCE ENGINEERING, 2004, 20B (01) : 30 - 33
  • [8] A TISSUE-EQUIVALENT GEL FOR NMR PHANTOMS
    DIXON, RL
    HINSON, WA
    EKSTRAND, KE
    MORAN, PR
    ROSEN, C
    MEDICAL PHYSICS, 1986, 13 (04) : 602 - 602
  • [9] TISSUE-EQUIVALENT PHANTOMS IN RADIOLOGICAL PROTECTION
    GUBATOVA, D
    VARCHENYA, V
    KRASTINYA, A
    KERNENERGIE, 1989, 32 (01): : 10 - 13
  • [10] Microwave imaging for tissue assessment: Initial evaluation in multitarget tissue-equivalent phantoms
    Meaney, PM
    Paulsen, KD
    Hartov, A
    Crane, RK
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1996, 43 (09) : 878 - 890