An exact reconstruction algorithm in variable pitch helical cone-beam CT when PI-line exists

被引:0
|
作者
Li, Liang [1 ]
Chen, Zhiqiang [1 ]
Zhang, Li [1 ]
Kang, Kejun [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
关键词
backprojection-filtration; cone-beam; image reconstruction; spring scan; PI-line;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, variable pitch helical cone-beam CT is studied. We prove a sufficient condition for the existence of PI-lines inside this variable pitch helix. Under this condition. we propose a new scanning configuration, called a spring scan, which can be used to scan a cylindrical object support. Based on Zou and Pan's BPF algorithm, we develop an exact BPF-type reconstruction algorithm for helical cone-beam CT in which the pitch of the helix varies with rotation angles. The algorithm includes four steps and can be used in region-of-interest (ROI) reconstruction by the PI-line determination step without a rebinning procedure as other BPF algorithms. Moreover, the algorithm can exactly reconstruct the object image only using the projection data within the Tam-Danielsson window, while; Katsevich's algorithm requires more data than it. Furthermore, we test the proposed algorithm using the 3D Shepp-Logan phantom by a spring scan. The numerical results are described to support the correctness of the algorithm.
引用
收藏
页码:109 / 118
页数:10
相关论文
共 50 条
  • [31] Exact radon rebinning algorithm for the long object problem in helical cone-beam CT
    Schaller, S
    Noo, F
    Sauer, F
    Tam, KC
    Lauritsch, G
    Flohr, T
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (05) : 361 - 375
  • [32] Minimum detection window and inter-helix PI-line with triple-source helical cone-beam scanning
    Zhao, Jun
    Jiang, Ming
    Zhuang, Tiange
    Wang, Ge
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2006, 14 (02) : 95 - 107
  • [33] Minimum detection window and inter-helix PI-line with triple-source helical cone-beam scanning
    Department of Biomedical Engineering, Shanghai Jiao Tong University, Shanghai, 200030, China
    不详
    不详
    SPIE, 1600, 599-610 (2004):
  • [34] Extended volume coverage in helical cone-beam CT by using PI-line-based BPF algorithm
    Cho, Seungryong
    Pan, Xiaochuan
    MEDICAL IMAGING 2007: PHYSICS OF MEDICAL IMAGING, PTS 1-3, 2007, 6510
  • [35] The n-PI-method for helical cone-beam CT
    Proksa, R
    Köhler, T
    Grass, M
    Timmer, J
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (09) : 848 - 863
  • [36] A rebinned backprojection-filtration algorithm for image reconstruction in helical cone-beam CT
    Yu, Lifeng
    Xia, Dan
    Zou, Yu
    Sidky, Emil Y.
    Bian, Junguo
    Pan, Xiaochuan
    PHYSICS IN MEDICINE AND BIOLOGY, 2007, 52 (18): : 5497 - 5508
  • [37] Reconstruction from minimum data in helical cone-beam CT
    Zou, Y
    Pan, XC
    2003 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-5, 2004, : 3235 - 3238
  • [38] Image reconstruction on PI-lines by use of filtered backprojection in helical cone-beam CT
    Zou, Y
    Pan, XC
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (12): : 2717 - 2731
  • [39] Accurate helical cone-beam CT reconstruction with redundant data
    Schoendube, Harald
    Stierstorfer, Karl
    Noo, Frederic
    PHYSICS IN MEDICINE AND BIOLOGY, 2009, 54 (15): : 4625 - 4644
  • [40] PI-Line Difference for Alignment and Motion-Correction of Cone-Beam Helical-Trajectory Micro-Tomography Data
    Delgado-Friedrichs, Olaf
    Kingston, Andrew Maurice
    Latham, Shane J.
    Myers, Glenn R.
    Sheppard, Adrian P.
    IEEE TRANSACTIONS ON COMPUTATIONAL IMAGING, 2020, 6 : 24 - 33