An exact reconstruction algorithm in variable pitch helical cone-beam CT when PI-line exists

被引:0
|
作者
Li, Liang [1 ]
Chen, Zhiqiang [1 ]
Zhang, Li [1 ]
Kang, Kejun [1 ]
机构
[1] Tsinghua Univ, Dept Engn Phys, Beijing 100084, Peoples R China
关键词
backprojection-filtration; cone-beam; image reconstruction; spring scan; PI-line;
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
In this paper, variable pitch helical cone-beam CT is studied. We prove a sufficient condition for the existence of PI-lines inside this variable pitch helix. Under this condition. we propose a new scanning configuration, called a spring scan, which can be used to scan a cylindrical object support. Based on Zou and Pan's BPF algorithm, we develop an exact BPF-type reconstruction algorithm for helical cone-beam CT in which the pitch of the helix varies with rotation angles. The algorithm includes four steps and can be used in region-of-interest (ROI) reconstruction by the PI-line determination step without a rebinning procedure as other BPF algorithms. Moreover, the algorithm can exactly reconstruct the object image only using the projection data within the Tam-Danielsson window, while; Katsevich's algorithm requires more data than it. Furthermore, we test the proposed algorithm using the 3D Shepp-Logan phantom by a spring scan. The numerical results are described to support the correctness of the algorithm.
引用
收藏
页码:109 / 118
页数:10
相关论文
共 50 条
  • [21] Exact and approximate algorithms for helical cone-beam CT
    Kudo, H
    Rodet, T
    Noo, F
    Defrise, M
    PHYSICS IN MEDICINE AND BIOLOGY, 2004, 49 (13): : 2913 - 2931
  • [22] Exact reconstruction for unequally spaced triple-source helical cone-beam CT
    Jin, Yannan
    Zhao, Jun
    Jiang, Ming
    Zhuang, Tiange
    Wang, Ge
    DEVELOPMENTS IN X-RAY TOMOGRAPHY V, 2006, 6318
  • [23] Generalized quasi-exact algorithms for image reconstruction in helical cone-beam CT
    Zou, Y
    Sidky, EY
    Pan, XC
    MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 696 - 702
  • [24] Cardiac cone-beam CT using a circle and line acquisition and an exact reconstruction
    Koken, Peter
    Bontus, Claas
    Koehler, Thomas
    Grass, Michael
    2005 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2005, : 2355 - 2358
  • [25] Exact cone-beam CT reconstruction with general line-circle trajectories
    National Laboratory of Pattern Recognition, Institute of Automation, Chinese Academy of Sciences, Beijing 100080, China
    不详
    Tien Tzu Hsueh Pao, 2007, 7 (1382-1386):
  • [26] Evaluation of helical cone-beam CT reconstruction algorithms
    Köhler, T
    Bontus, C
    Brown, K
    Heuscher, D
    Grass, M
    Shechter, G
    Proksa, R
    2002 IEEE NUCLEAR SCIENCE SYMPOSIUM, CONFERENCE RECORD, VOLS 1-3, 2003, : 1217 - 1220
  • [27] An Improved Helical Cone-beam CT Image Reconstruction
    Gao, Yang
    Ma, Jianhua
    Chen, Wufan
    2009 3RD INTERNATIONAL CONFERENCE ON BIOINFORMATICS AND BIOMEDICAL ENGINEERING, VOLS 1-11, 2009, : 2178 - 2182
  • [28] Exact helical reconstruction using native cone-beam geometries
    Noo, F
    Pack, J
    Heuscher, D
    PHYSICS IN MEDICINE AND BIOLOGY, 2003, 48 (23): : 3787 - 3818
  • [29] Minimum detection window and inter-helix PI-Line with triple-source helical cone-beam scanning
    Zhao, J
    Jiang, M
    Zhuang, TG
    Wang, G
    DEVELOPMENTS IN X-RAY TOMOGRAPHY IV, 2004, 5535 : 599 - 610
  • [30] Feldkamp-type reconstruction algorithms for spiral cone-beam CT with variable pitch
    Zhao, Jun
    Lu, Yang
    Jin, Yannan
    Bai, Erwei
    Wang, Ge
    JOURNAL OF X-RAY SCIENCE AND TECHNOLOGY, 2007, 15 (04) : 177 - 196