Dual-energy contrast enhanced digital mammography using a new approach for breast tissue canceling

被引:5
|
作者
Puong, Sylvie [1 ,2 ]
Bouchevreau, Xavier [3 ]
Patoureaux, Fanny [2 ]
Iordache, Razvan [2 ]
Muller, Serge [2 ]
机构
[1] Univ Paris 11, Bat 425, Orsay, France
[2] GE Hlthcare, Buc, France
[3] Altran, Paris, France
关键词
digital mammography; contrast medium; contrast enhanced digital mammography; dual-energy; algorithm description;
D O I
10.1117/12.710133
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
In this study, we propose a novel approach to dual-energy contrast-enhanced digital mammography, with the development of a dual-energy recombination algorithm based on an image chain model and the determination of the associated optimal low and high-energy techniques. Our method produces clutter-free iodine-equivalent images and includes thickness correction near the breast border. After the algorithm description, the optimal low and high-energy acquisition techniques are determined to obtain a compromise between image quality and glandular dose. The low and high-energy techniques were chosen to minimize the glandular dose for a target Signal Difference to Noise Ratio (SDNR) in the dual-energy recombined image. The theoretical derivation of the iodine SDNR in the recombined image allowed the prediction of the optimal low and high-energy techniques. Depending on the breast thickness and glandular percentage, the optimal low-energy kVp and mAs ranged from 24kVp (Mo/Mo or Mo/Rh) to 35kVp (Rh/Rh), and from 60 to 90mAs respectively, and the high-energy kVp and mAs ranged from 40kVp to 47kVp (Mo/Cu), and from 80mAs to 290mAs. We proved the better :performance of our algorithm compared to the classic weighted logarithmic subtraction method in terms of patient dose and also in terms of texture cancelation, through the use of artificial textured images. Values of iodine contrast measured on phantom were close to the expected iodine thickness. Good correlation was found between the measured and theoretical iodine SDNR in the dual-energy images, which validates our theoretical optimization of the acquisition techniques.
引用
收藏
页数:12
相关论文
共 50 条
  • [1] Contrast-enhanced dual-energy digital mammography in the evaluation of breast cancer
    Awad, Fatma Mohamed
    Ismaeil, Hanaa
    EGYPTIAN JOURNAL OF RADIOLOGY AND NUCLEAR MEDICINE, 2014, 45 (02): : 591 - 595
  • [2] Dual-energy contrast-enhanced digital mammography: Examination protocol
    Barra, F. R.
    Ribeiro, A. C.
    Mathieu, O. D.
    Rodrigues, A. C.
    DIAGNOSTIC AND INTERVENTIONAL IMAGING, 2014, 95 (03) : 351 - 352
  • [3] Dual-energy contrast-enhanced digital subtraction mammography: Feasibility
    Lewin, JM
    Isaacs, PK
    Vance, V
    Larke, FJ
    RADIOLOGY, 2003, 229 (01) : 261 - 268
  • [4] Estimating breast thickness for dual-energy subtraction in contrast-enhanced digital mammography using calibration phantoms
    Lau, Kristen C.
    Kwon, Young Joon
    Aziz, Moez Karim
    Acciavatti, Raymond J.
    Maidment, Andrew D. A.
    MEDICAL IMAGING 2016: PHYSICS OF MEDICAL IMAGING, 2016, 9783
  • [5] Dual-energy contrast-enhanced mammography
    Travieso Aja, M. M.
    Rodriguez Rodriguez, M.
    Mayon Hernandez, S.
    Vega Benitez, V.
    Luzardo, O. P.
    RADIOLOGIA, 2014, 56 (05): : 390 - 399
  • [6] Contrast-enhanced dual-energy digital subtraction mammography: Optimization of the beam energy
    Kwan, ALC
    Boone, JM
    Le-Petross, H
    Lindfors, KK
    Seibert, JA
    Lewin, JM
    Medical Imaging 2005: Physics of Medical Imaging, Pts 1 and 2, 2005, 5745 : 1317 - 1321
  • [7] Dual-energy contrast-enhanced digital mammography: initial clinical results
    Dromain, Clarisse
    Thibault, Fabienne
    Muller, Serge
    Rimareix, Francoise
    Delaloge, Suzette
    Tardivon, Anne
    Balleyguier, Corinne
    EUROPEAN RADIOLOGY, 2011, 21 (03) : 565 - 574
  • [8] Role of preoperative breast dual-energy contrast-enhanced digital mammography in ductal carcinoma in situ
    Vignoli, Chiara
    Bicchierai, Giulia
    De Benedetto, Diego
    Boeri, Cecilia
    Vanzi, Ermanno
    Miele, Vittorio
    Cirone, Donatello
    Nori, Jacopo
    BREAST JOURNAL, 2019, 25 (05): : 1034 - 1036
  • [9] Estimating Breast Thickness for Dual-Energy Subtraction in Contrast-Enhanced Digital Mammography: A Theoretical Model
    Lau, Kristen C.
    Acciavatti, Raymond J.
    Maidment, Andrew D. A.
    BREAST IMAGING, IWDM 2016, 2016, 9699 : 593 - 600
  • [10] Dual-energy contrast-enhanced digital mammography: initial clinical results
    Clarisse Dromain
    Fabienne Thibault
    Serge Muller
    Françoise Rimareix
    Suzette Delaloge
    Anne Tardivon
    Corinne Balleyguier
    European Radiology, 2011, 21 : 565 - 574