An online x-ray based position validation system for prostate hypofractionated radiotherapy

被引:20
|
作者
Arumugam, Sankar [1 ,2 ]
Sidhom, Mark [3 ]
Xing, Aitang [1 ,2 ]
Holloway, Lois [1 ,2 ,4 ,5 ,6 ]
机构
[1] Liverpool & Macarthur Canc Therapy Ctr, Dept Med Phys, Liverpool, NSW 2170, Australia
[2] Ingham Inst, Liverpool, NSW 2170, Australia
[3] Liverpool & Macarthur Canc Therapy Ctr, Dept Radiat Oncol, Liverpool, NSW 2170, Australia
[4] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW 2522, Australia
[5] Univ New S Wales, South Western Clin Sch, Sydney, NSW 2052, Australia
[6] Univ Sydney, Inst Med Phys, Sch Phys, Sydney, NSW 2006, Australia
关键词
SBRT; autosegmentation; online monitoring; monoscopic image; STEREOTACTIC BODY RADIOTHERAPY; MOTION; LOCALIZATION; EXPERIENCE;
D O I
10.1118/1.4940351
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Accurate positioning of the target volume during treatment is paramount for stereotactic body radiation therapy (SBRT). In this work, the authors present the development of an in-house software tool to verify target position with an Elekta-Synergy linear accelerator using kV planar images acquired during treatment delivery. Methods: In-house software, SeedTracker, was developed in MATLAB to perform the following three functions: 1. predict intended seed positions in a planar view perpendicular to any gantry angle, simulating a portal imaging device, from the 3D seed co-ordinates derived from the treatment planning system; 2. autosegment seed positions in kV planar images; and 3. report the position shift based on the seed positions in the projection images. The performance of SeedTracker was verified using a CIRS humanoid phantom (CIRS, VA, USA) implanted with three Civco gold seed markers (Civco, IA, USA) in the prostate. The true positive rate of autosegmentation (TPR g) and the accuracy of the software in alerting the user when the isocenter position was outside the tolerance (TPRtng) were studied. Two-dimensional and 3D static position offsets introduced to the humanoid phantom and 3D dynamic offsets introduced to a gel phantom containing gold seeds were used for evaluation of the system. Results: SeedTracker showed a TPR g of 100% in the humanoid phantom for projection images acquired at all angles except in the ranges of 80-100 and 260-280 where seeds are obscured by anatomy. This resulted in a TPRtrig of 88% over the entire treatment range for considered 3D static offsets introduced to the phantom. For 2D static offsets where the position offsets were only introduced in the anterior posterior and lateral directions, the TPRtrig of SeedTracker was limited by both seed detectability and positional offset. SeedTracker showed a false positive trigger in the projection angle range between 130-170 and 310-350 (a maximum of 24% of treatment time) due to limited information that can be derived from monoscopic images. The system accurately determined the dynamic trajectory of the isocenter position in the superior and inferior direction for the studied dynamic offset scenarios based on the seed position in monoscopic images Conclusions: The developed software has been shown to accurately autosegment the seed positions in kV planar images except for two 20 arcs where seeds are obscured by anatomical structures. The isocenter trajectories determined by the system, based on the monoscopic images, provide useful information for monitoring the prostate position. The developed system has potential application for monitoring prostate position during treatment delivery in linear accelerator based SBRT. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:961 / 974
页数:14
相关论文
共 50 条
  • [1] A simple X-ray position detection system based on a MHSP
    da Luz, H. Natal
    Veloso, J. F. C. A.
    dos Santos, J. M. F.
    Mir, J. A.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2007, 580 (02): : 1083 - 1086
  • [2] A NEW SYSTEM FOR ONLINE X-RAY TOPOGRAPHY
    KOMYAK, NI
    LUTSAU, VG
    EFANOV, VP
    IVANOV, SA
    X-RAY SPECTROMETRY, 1980, 9 (01) : 36 - 37
  • [3] Experiment and Validation System for X-ray Pulsar-Based Navigation
    Su, Zhe
    Meng, Yansong
    Xu, Qibing
    Wang, Xiaoliang
    Feng, Xingang
    CHINA SATELLITE NAVIGATION CONFERENCE (CSNC) 2013 PROCEEDINGS: PRECISE ORBIT DETERMINATION & POSITIONING, ATOMIC CLOCK TECHNIQUE & TIME-FREQUENCY SYSTEM, INTEGRATED NAVIGATION & NEW METHODS, 2013, 245 : 489 - 496
  • [4] X-RAY IMAGE SYSTEM REQUIREMENTS FOR RADIOTHERAPY SIMULATORS
    CLARKE, OF
    PHYSICS IN MEDICINE AND BIOLOGY, 1983, 28 (10): : 1163 - 1163
  • [5] High-dose hypofractionated X-ray radiotherapy for hepatocellular carcinoma: Tumor responses and toxicities
    Huang, Bing-Shen
    Tsang, Ngan-Ming
    Lin, Shi-Ming
    Lin, Deng-Yn
    Lien, Jau-Min
    Lin, Chen-Chun
    Chen, Wei-Ting
    Chen, Wan-Yu
    Hong, Ji-Hong
    ONCOLOGY LETTERS, 2013, 6 (05) : 1514 - 1520
  • [6] Development of online cable eccentricity detection system based on X-ray CCD
    Chen, Jian-Zhen
    Li, Bin
    Wei, Kai-Xia
    Guo, Lan-Ying
    Qu, Guo-Pu
    Hedianzixue Yu Tance Jishu/Nuclear Electronics and Detection Technology, 2007, 27 (02): : 230 - 233
  • [7] A New High Energy X-Ray Imaging Mode for Position Verification in Radiotherapy
    Quanshi, Z.
    Xiwen, W.
    Qiyin, S.
    Yuehui, J.
    Yun, L.
    Pengcheng, Z.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [8] Hypofractionated radiotherapy of the prostate using a MRgRT system - are there any disadvantages?
    Mannerberg, A.
    Persson, E.
    Jonsson, J.
    Gustafsson, C. Jamtheim
    Gunnlaugsson, A.
    Olsson, L. E.
    Ceberg, S.
    RADIOTHERAPY AND ONCOLOGY, 2020, 152 : S260 - S260
  • [9] Ultra-Hypofractionated Prostate Radiotherapy With Online Adaptive Technique: A Case Report
    Yoganathan, S. A.
    Riyas, Mohamed
    Sukumaran, Renilmon
    Hammoud, Rabih
    Al-Hammadi, Noora
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2024, 16 (07)
  • [10] Validation of X-ray lithography and development simulation system for moving mask deep X-ray lithography
    Hirai, Y
    Hafizovic, S
    Matsuzuka, N
    Korvink, JG
    Tabata, O
    JOURNAL OF MICROELECTROMECHANICAL SYSTEMS, 2006, 15 (01) : 159 - 168