An online x-ray based position validation system for prostate hypofractionated radiotherapy

被引:20
|
作者
Arumugam, Sankar [1 ,2 ]
Sidhom, Mark [3 ]
Xing, Aitang [1 ,2 ]
Holloway, Lois [1 ,2 ,4 ,5 ,6 ]
机构
[1] Liverpool & Macarthur Canc Therapy Ctr, Dept Med Phys, Liverpool, NSW 2170, Australia
[2] Ingham Inst, Liverpool, NSW 2170, Australia
[3] Liverpool & Macarthur Canc Therapy Ctr, Dept Radiat Oncol, Liverpool, NSW 2170, Australia
[4] Univ Wollongong, Ctr Med Radiat Phys, Wollongong, NSW 2522, Australia
[5] Univ New S Wales, South Western Clin Sch, Sydney, NSW 2052, Australia
[6] Univ Sydney, Inst Med Phys, Sch Phys, Sydney, NSW 2006, Australia
关键词
SBRT; autosegmentation; online monitoring; monoscopic image; STEREOTACTIC BODY RADIOTHERAPY; MOTION; LOCALIZATION; EXPERIENCE;
D O I
10.1118/1.4940351
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: Accurate positioning of the target volume during treatment is paramount for stereotactic body radiation therapy (SBRT). In this work, the authors present the development of an in-house software tool to verify target position with an Elekta-Synergy linear accelerator using kV planar images acquired during treatment delivery. Methods: In-house software, SeedTracker, was developed in MATLAB to perform the following three functions: 1. predict intended seed positions in a planar view perpendicular to any gantry angle, simulating a portal imaging device, from the 3D seed co-ordinates derived from the treatment planning system; 2. autosegment seed positions in kV planar images; and 3. report the position shift based on the seed positions in the projection images. The performance of SeedTracker was verified using a CIRS humanoid phantom (CIRS, VA, USA) implanted with three Civco gold seed markers (Civco, IA, USA) in the prostate. The true positive rate of autosegmentation (TPR g) and the accuracy of the software in alerting the user when the isocenter position was outside the tolerance (TPRtng) were studied. Two-dimensional and 3D static position offsets introduced to the humanoid phantom and 3D dynamic offsets introduced to a gel phantom containing gold seeds were used for evaluation of the system. Results: SeedTracker showed a TPR g of 100% in the humanoid phantom for projection images acquired at all angles except in the ranges of 80-100 and 260-280 where seeds are obscured by anatomy. This resulted in a TPRtrig of 88% over the entire treatment range for considered 3D static offsets introduced to the phantom. For 2D static offsets where the position offsets were only introduced in the anterior posterior and lateral directions, the TPRtrig of SeedTracker was limited by both seed detectability and positional offset. SeedTracker showed a false positive trigger in the projection angle range between 130-170 and 310-350 (a maximum of 24% of treatment time) due to limited information that can be derived from monoscopic images. The system accurately determined the dynamic trajectory of the isocenter position in the superior and inferior direction for the studied dynamic offset scenarios based on the seed position in monoscopic images Conclusions: The developed software has been shown to accurately autosegment the seed positions in kV planar images except for two 20 arcs where seeds are obscured by anatomical structures. The isocenter trajectories determined by the system, based on the monoscopic images, provide useful information for monitoring the prostate position. The developed system has potential application for monitoring prostate position during treatment delivery in linear accelerator based SBRT. (C) 2016 American Association of Physicists in Medicine.
引用
收藏
页码:961 / 974
页数:14
相关论文
共 50 条
  • [21] X-RAY EXPOSURE SYSTEM USING FINELY POSITION ADJUSTING APPARATUS
    YAMAZAKI, S
    NAKAYAMA, S
    HAYASAKA, T
    ISHIHARA, S
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY, 1978, 15 (03): : 987 - 991
  • [22] NOVEL X-RAY DIFFRACTOMETER POSITION-SENSITIVE DETECTOR SYSTEM
    FRAASS, BA
    GRANFORS, PR
    HILLEKE, RO
    SIMMONS, RO
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1984, 55 (09): : 1455 - 1460
  • [23] Latency and throughput of online processing in Soft X-Ray GEM-based measurement system
    Linczuk, P.
    Krawczyk, R.
    Wojenski, A.
    Zabolotny, W.
    Chernyshova, M.
    Pozniak, K.
    Czarski, T.
    Gaska, M.
    Kasprowicz, G.
    Kolasinski, P.
    Kowalska-Strzeciwilk, E.
    Malinowski, K.
    JOURNAL OF INSTRUMENTATION, 2019, 14
  • [24] Development of X-ray CCD camera based X-ray micro-CT system
    Sarkar, Partha S.
    Ray, N. K.
    Pal, Manoj K.
    Baribaddala, Ravi
    Agrawal, Ashish
    Kashyap, Y.
    Sinha, A.
    Gadkari, S. C.
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2017, 88 (02):
  • [25] X-RAY EXAMINATION IN CARCINOMA OF PROSTATE
    SCHMOLLER, H
    WIENER MEDIZINISCHE WOCHENSCHRIFT, 1977, 127 (15) : 474 - 477
  • [26] Field Emission X-ray System for Online Conveyor Belt Imaging
    Zhou, Rui
    Wang, Jiaqi
    Xie, Zhemiao
    Yeow, John T. W.
    2024 37TH INTERNATIONAL VACUUM NANOELECTRONICS CONFERENCE, IVNC 2024, 2024,
  • [27] THE X-RAY IMAGES OF THE PROSTATE TUBERCULOSIS
    Stenstrom, Bo
    ACTA RADIOLOGICA, 1939, 20 (02) : 303 - 313
  • [28] X-RAY TREATMENT OF HYPERTROPHY OF THE PROSTATE
    Stern, Samuel
    AMERICAN JOURNAL OF ROENTGENOLOGY, 1921, 8 (06) : 292 - 294
  • [29] X-ray spectrometry using polycapillary X-ray optics and position sensitive detector
    Ding, XL
    Xie, JD
    He, YJ
    Pan, QL
    Yan, YM
    TALANTA, 2000, 53 (01) : 17 - 22
  • [30] Chemical validation of X-ray absorptiometry
    Klevay, LM
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 2004, 79 (05): : 887 - 887