Development of fully automated quantitative capillary electrophoresis with high accuracy and repeatability

被引:8
|
作者
Xu, Yuan [1 ]
Ling, Bang-zan [1 ]
Zhu, Wen-jun [1 ,2 ]
Yao, Dong [2 ]
Zhang, Lin [1 ,2 ]
Wang, Yan [1 ]
Yan, Chao [1 ]
机构
[1] Shanghai Jiao Tong Univ, Sch Pharm, Shanghai 200240, Peoples R China
[2] Unimicro Shanghai Technol, Shanghai 201203, Peoples R China
基金
中国国家自然科学基金;
关键词
automation; electric decoupler; nano-valve; quantitative capillary electrophoresis; SAMPLE INJECTION; PRECONCENTRATION; REPRODUCIBILITY; PARAMETERS;
D O I
10.1002/bmc.3560
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A quantitative capillary electrophoresis (qCE) was developed by utilizing a rotary type of nano-volume injector, an autosampler, and a thermostat with cooling capacity. The accuracy and precision were greatly improved compared with conventional capillary electrophoresis. The 10 nL volume accuracy was guaranteed by the carefully designed nano-injector with an accurate internal loop. The system repeatability (precision) in terms of RSD <0.5% for migration time and 1% for peak area were achieved by using DMSO as a test sample. We believe that this fully automated qCE system has the potential to be employed broadly in quality control and quality assurance in the pharmaceutical industry. Copyright (c) 2015 John Wiley & Sons, Ltd.
引用
收藏
页码:390 / 395
页数:6
相关论文
共 50 条
  • [21] Flow variation as a factor determining repeatability of the internal standard-based qualitative and quantitative analyses by capillary electrophoresis
    Nowak, Pawel Mateusz
    Wozniakiewicz, Michal
    Koscielniak, Pawel
    JOURNAL OF CHROMATOGRAPHY A, 2018, 1548 : 92 - 99
  • [22] Quantitative determination of brain ganglioside compositions by high performance capillary electrophoresis
    Yu, ZL
    Xu, GY
    Chang, LW
    JOURNAL OF NEUROCHEMISTRY, 1996, 67 : S7 - S7
  • [23] Quantitative sample injection for capillary electrophoresis
    Yao, CY
    Gao, RY
    Yan, C
    JOURNAL OF SEPARATION SCIENCE, 2003, 26 (1-2): : 37 - 42
  • [24] QUANTITATIVE PHARMACEUTICAL ANALYSIS BY CAPILLARY ELECTROPHORESIS
    ALTRIA, KD
    FILBEY, SD
    JOURNAL OF LIQUID CHROMATOGRAPHY, 1993, 16 (11): : 2281 - 2292
  • [25] Fully-automated capillary zone electrophoresis for the identification and typing of Bence Jones Protein: a preliminary report
    Plebani, M
    Mussap, M
    Zaninotto, M
    Varagnolo, MC
    Ponchia, S
    CLINICAL CHEMISTRY, 2004, 50 (06) : A62 - A63
  • [26] Microfabricated liquid junction hybrid capillary electrophoresis-mass spectrometry interface for fully automated operation
    Krenkova, Jana
    Kleparnik, Karel
    Luksch, Jaroslav
    Foret, Frantisek
    ELECTROPHORESIS, 2019, 40 (18-19) : 2263 - 2270
  • [27] Fully automated high-throughput 2D electrophoresis system
    Yokoyama, K.
    Hiratsuka, A.
    Suzuki, Y.
    Kinoshita, H.
    Usui, K.
    Shiseki, K.
    Akutsu, S.
    Yano, K.
    Unuma, Y.
    Maruo, Y.
    Takahashi, K.
    Mieda, M.
    Matsushima, T.
    Nakamura, M.
    Sakairi, K.
    Hayashida, C.
    Ueyama, K.
    Karube, I.
    MOLECULAR & CELLULAR PROTEOMICS, 2006, 5 (10) : S6 - S6
  • [28] An Innovative and Fully Automated System for Gel Electrophoresis
    Theodoridis, Konstantinos
    Stergiopoulos, Fotis
    Bechtsis, Dimitrios
    Nikolaidis, Nikolaos
    Triantafyllidis, Dimitrios
    Tsagaris, Apostolos
    Filelis, Anastasios
    Papaikonomou, Asterios
    30TH EUROPEAN SYMPOSIUM ON COMPUTER AIDED PROCESS ENGINEERING, PTS A-C, 2020, 48 : 847 - 852
  • [29] Quantitative MRI: Defining repeatability, reproducibility and accuracy for prostate cancer imaging biomarker development
    Wang, Y.
    Tadimalla, S.
    Rai, R.
    Goodwin, J.
    Foster, S.
    Liney, G.
    Holloway, L.
    Haworth, A.
    MAGNETIC RESONANCE IMAGING, 2021, 77 : 169 - 179
  • [30] An automated capillary electrophoresis system for high-speed separation of DNA fragments based on a short capillary
    Cheng, Yong-Qiang
    Yao, Bo
    Zhang, Hui-Dan
    Fang, Jin
    Fang, Qun
    ELECTROPHORESIS, 2010, 31 (19) : 3184 - 3191