A double microsecond-pulsed glow discharge ion source

被引:23
|
作者
Pisonero, J
Turney, K
Bordel, N
Sanz-Medel, A
Harrison, WW [1 ]
机构
[1] Univ Florida, Dept Chem, Gainesville, FL 32611 USA
[2] Univ Oviedo, Dept Phys, Oviedo 33007, Spain
[3] Univ Oviedo, Dept Phys & Analyt Chem, E-33006 Oviedo, Spain
关键词
D O I
10.1039/b300518f
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A double pulsed glow discharge was compared to the single pulsed mode as an ion source for atomic mass spectrometry. During the time-window between the first applied voltage pulse and signal collection, the second pulse is applied. The double pulse was used to enhance analyte ionization and study the timing sequences within the pulsed glow discharge, the signals from which were followed using a time-of-flight mass spectrometer. Results showed that the double pulse glow discharge increased ion signals, provided that appropriate pulsing delays and gas flow rates were applied. The effect of the double pulse on methane-enhanced polyatomic cluster formation has also been evaluated.
引用
收藏
页码:624 / 628
页数:5
相关论文
共 50 条
  • [21] Model of microsecond pulsed glow discharge in hollow cathode for mass spectrometry
    Voronov, M.
    Ganeev, A.
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2009, 64 (05) : 416 - 426
  • [22] A microsecond-pulsed cold plasma jet for medical application
    Zheng C.
    Kou Y.
    Liu Z.
    Zhu A.
    Jiang H.
    Huang Y.
    Yan K.
    Liu, Zhen (zliu@zju.edu.cn), 1600, Begell House Inc. (06): : 179 - 191
  • [23] Pulsed glow discharge as a solids analysis source
    Harrison, WW
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1998, 13 (09) : 1051 - 1056
  • [24] Experimental study of a microsecond-pulsed cold plasma jet
    S. Mashayekh
    N. Cvetanović
    G. B. Sretenović
    B. M. Obradović
    Z. Liu
    K. Yan
    M. M. Kuraica
    The European Physical Journal D, 2023, 77
  • [25] Microsecond-pulsed dielectric barrier discharge plasma stimulation of tissue macrophages for treatment of peripheral vascular disease
    Miller, V.
    Lin, A.
    Kako, F.
    Gabunia, K.
    Kelemen, S.
    Brettschneider, J.
    Fridman, G.
    Fridman, A.
    Autieri, M.
    PHYSICS OF PLASMAS, 2015, 22 (12)
  • [26] Study of a pulsed glow discharge ion source for time-of-flight mass spectrometry
    Su, YX
    Zhou, Z
    Yang, PY
    Wang, XR
    Huang, BL
    SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 1997, 52 (05) : 633 - 641
  • [27] Microsecond-Pulsed Dielectric Barrier Discharge Plasma-Treated Mist for Inactivation of Escherichia coli In Vitro
    Ranieri, Pietro, III
    McGovern, Gerard
    Tse, Henry
    Fulmer, Alexander
    Kovalenko, Mykola
    Nirenberg, Gary
    Miller, Vandana
    Fridman, Alexander
    Rabinovich, Alexander
    Fridman, Gregory
    IEEE TRANSACTIONS ON PLASMA SCIENCE, 2019, 47 (01) : 395 - 402
  • [28] A pulsed Grimm glow discharge as an atomic emission source
    Yang, CL
    Ingeneri, K
    Harrison, WW
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 1999, 14 (04) : 693 - 698
  • [29] Ion transport diagnostics in microsecond pulsed Grimm-type glow discharge time-of-flight mass spectrometer
    Oxley, E
    Yang, CL
    Liu, J
    Harrison, WW
    ANALYTICAL CHEMISTRY, 2003, 75 (23) : 6478 - 6484
  • [30] Ion formation in millisecond pulsed glow discharge plasmas
    DeJesus, Megan R.
    Gu, Guodong
    King, Fred L.
    Barnes, James H.
    Lewis, Cris L.
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2011, 26 (11) : 2206 - 2215