Feasibility of Dual-Energy CT in the Arterial Phase: Imaging After Endovascular Aortic Repair

被引:45
|
作者
Numburi, Uma D. [1 ,2 ,3 ]
Schoenhagen, Paul [1 ,2 ]
Flamm, Scott D. [1 ]
Greenberg, Roy K. [3 ,4 ,5 ]
Primak, Andrew N. [6 ]
Saba, Osama I. [6 ]
Lieber, Michael L. [7 ]
Halliburton, Sandra S. [1 ,2 ,3 ]
机构
[1] Cleveland Clin, Image Inst, Cleveland, OH 44195 USA
[2] Cleveland State Univ, Chem & Biomed Engn Dept, Cleveland, OH 44115 USA
[3] Cleveland Clin, Lerner Res Inst, Dept Biomed Engn, Cleveland, OH 44195 USA
[4] Cleveland Clin, Inst Heart & Vasc, Dept Vasc Surg, Cleveland, OH 44195 USA
[5] Cleveland Clin, Inst Heart & Vasc, Dept Thorac & Cardiovasc Surg, Cleveland, OH 44195 USA
[6] Siemens Healthcare, Malvern, PA USA
[7] Cleveland Clin, Lerner Res Inst, Dept Quantitat Hlth Sci, Cleveland, OH 44195 USA
关键词
aneurysm; aorta; dual-energy CT; endovascular repair; unenhanced CT; virtual CT; COMPUTED-TOMOGRAPHY; MULTIDETECTOR CT; ANEURYSM;
D O I
10.2214/AJR.09.3872
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
OBJECTIVE. The purpose of this study was to investigate replacing unenhanced and arterial single-energy CT acquisitions after endovascular aneurysm repair with one dual-energy CT arterial acquisition. SUBJECTS AND METHODS. Thirty patients underwent arterial dual-energy CT (80 and 140 kVp) and venous single-energy CT (120 kVp) after endovascular aneurysm repair, and the radiation doses were compared with those of a standard triple-phase protocol. Both virtual unenhanced and arterial images were generated with dual-energy CT. Images were reviewed clinically for detection of endoleaks and evaluation of stent and calcium appearance. The aortic luminal attenuation on virtual unenhanced CT images was compared with that on previously acquired true unenhanced images. Virtual unenhanced, arterial, and venous images were compared for thrombus attenuation. Single-energy CT and dual-energy CT images were compared for noise. RESULTS. Replacement of two (unenhanced, arterial) of three single-energy CT acquisitions with one dual-energy CT acquisition resulted in 31% radiation dose savings. All images were clinically interpretable. Thoracic (32 +/- 2 vs 35 +/- 4 HU) and abdominal (30 +/- 3 vs 35 +/- 5 HU) aortic attenuation was similar on virtual unenhanced and true unenhanced images. Thrombus attenuation was similar on virtual unenhanced (32 +/- 6 HU), arterial phase (33 +/- 7 HU), and venous phase (34 +/- 6 HU) images. Decreased stent and calcium attenuation was observed at some locations on virtual unenhanced images. Noise in the thoracic (10 +/- 1 HU) and abdominal (12 +/- 2 HU) aorta was lower on virtual unenhanced images than on true unenhanced images (13 +/- 4 HU, 19 +/- 5 HU). Noise was comparable for dual-energy and single-energy CT (thorax, 16 +/- 2 vs 13 +/- 2 HU; abdomen, 21 +/- 3 vs 23 +/- 5 HU). CONCLUSION. Virtual unenhanced and arterial phase images derived from dual-energy CT can replace true unenhanced and arterial phase single-energy CT images in follow-up after endovascular aneurysm repair (except immediately after the procedure), providing comparable diagnostic information with substantial dose savings.
引用
收藏
页码:486 / 493
页数:8
相关论文
共 50 条
  • [31] Abdominal aortic aneurysm: Can the arterial phase at CT evaluation after endovascular repair be eliminated to reduce radiation dose?
    Macari, Michael
    Chandarana, Hersh
    Schmidt, Bernhardt
    Lee, Julie
    Lamparello, Patrick
    Babb, James
    RADIOLOGY, 2006, 241 (03) : 908 - 914
  • [32] Dual-Energy CT: Applications in Abdominal Imaging
    Bauer R.W.
    Fischer S.
    Current Radiology Reports, 3 (4)
  • [33] Numerical Simulation for Dual-energy CT Imaging
    Wang, Lixin
    Sun, Fengrong
    Babyn, Paul
    Zhong, Hai
    Zhou, Zhenzhen
    Huang, Hao
    Qin, Jiaojiao
    PROCEEDINGS OF THE 2015 2ND INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER ENGINEERING AND ELECTRONICS (ICECEE 2015), 2015, 24 : 316 - 320
  • [34] Dual-energy CT imaging of thoracic malignancies
    Zhang, Long Jiang
    Yang, Gui Fen
    Wu, Sheng Yong
    Xu, Jian
    Lu, Guang Ming
    Schoepf, U. Joseph
    CANCER IMAGING, 2013, 13 (01): : 81 - 91
  • [35] Advances of dual source, dual-energy imaging in postmortem CT
    Persson, Anders
    Jackowski, Christian
    Engstrom, Elias
    Zachrisson, Helene
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 68 (03) : 446 - 455
  • [36] Dual-Energy CT Imaging in Diagnostic Imaging and Radiation Therapy
    Molloi, S.
    Li, B.
    Yin, F.
    Chen, H.
    MEDICAL PHYSICS, 2014, 41 (06) : 486 - 487
  • [37] Imaging after endovascular repair of abdominal aortic aneurysm
    J. Golzarian
    Abdominal Imaging, 2003, 28 : 0236 - 0243
  • [38] Imaging after endovascular repair of abdominal aortic aneurysm
    Golzarian, J
    ABDOMINAL IMAGING, 2002, 28 (02): : 236 - 243
  • [39] Performance evaluation of dual-energy CT and differential phase contrast CT in quantitative imaging applications
    Zhang, Xin
    Su, Ting
    Yang, Jiecheng
    Zhu, Jiongtao
    Xia, Dongmei
    Zheng, Hairong
    Liang, Dong
    Ge, Yongshuai
    MEDICAL PHYSICS, 2022, 49 (02) : 1123 - 1138
  • [40] Feasibility of extracellular volume quantification using dual-energy CT
    van Assen, Marly
    De Cecco, Carlo N.
    Sahbaee, Pooyan
    Eid, Marwen H.
    Griffith, L. Parkwood
    Bauer, Maximilian J.
    Savage, Rock H.
    Varga-Szemes, Akos
    Oudkerk, Matthijs
    Vliegenthart, Rozemarijn
    Schoepf, U. Joseph
    JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2019, 13 (01) : 81 - 84